MAXON pilot selection follows the associated burner family rather than one universal pilot design.

MAXON pilot selection follows the associated burner family rather than one universal pilot design. This reference supplements individual burner catalog sections with component identifiers and performance data. It supports matching the ignition assembly to the main burner, including accessories needed for the selected fuel and control arrangement.

Features & Benefits

Capacity
Stated in 1,000 BTU/hr depending on assembly (varies by model)
Ignition Gap Requirement
0.05 to 0.06 in for 10 or 18 mm ignitors
Environment Limitations
Not for outdoor or high‑draft use
Pilot Air Requirement
Required for premix and air-assisted pilots
Alternative Port Type
Sealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®)
Burner Compatibility
STICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME®
Pilot Gas Pressure
Provided in in water column (in wc) or ounces depending on pilot model
Purge Requirement
Full system purge before ignition
Mounting Options
Side-mounted/End-mounted (for LINOFLAME and LINOPAK)
Connection Type
ANSI B2.1 pipe threads
Ignition Type
Spark ignitor or gas ignitor depending on model
Pilot Style
Atmospheric open‑port and venturi open‑port
Mixer Type
Adjustable air-gas mixer

Applications

  • Burner-specific MAXON pilot selection

Specifications

Performance Specifications

Capacity
Stated in 1,000 BTU/hr depending on assembly (varies by model)

Ignition, Flame & Supervision Specifications

Ignition Gap Requirement
0.05 to 0.06 in for 10 or 18 mm ignitors
Purge Requirement
Full system purge before ignition
Ignition Type
Spark ignitor or gas ignitor depending on model

Environmental Conditions

Environment Limitations
Not for outdoor or high‑draft use

Air & Combustion Air Specifications

Pilot Air Requirement
Required for premix and air-assisted pilots

Actuation, Valve & Motion Control Specifications

Alternative Port Type
Sealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®)

Applications & Compatibility

Burner Compatibility
STICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME®
Applications
Used for manual light-off and are not intended as permanent pilots.

Pressure Specifications

Pilot Gas Pressure
Provided in in water column (in wc) or ounces depending on pilot model

Installation & Mounting Specifications

Mounting Options
Side-mounted/End-mounted (for LINOFLAME and LINOPAK)

Connections & Interfaces

Connection Type
ANSI B2.1 pipe threads

Combustion, Fuel & Mixing Sub‑Systems

Pilot Style
Atmospheric open‑port and venturi open‑port

Mixing & Combustion Sub‑Components

Mixer Type
Adjustable air-gas mixer
Maxon Pilots — manufacturer page values
ParameterPublished value / configuration
CapacityStated in 1,000 BTU/hr depending on assembly (varies by model)
Ignition Gap Requirement0.05 to 0.06 in for 10 or 18 mm ignitors
Purge RequirementFull system purge before ignition
Ignition TypeSpark ignitor or gas ignitor depending on model
Environment LimitationsNot for outdoor or high‑draft use
Pilot Air RequirementRequired for premix and air-assisted pilots
Alternative Port TypeSealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®)
Burner CompatibilitySTICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME®
ApplicationsUsed for manual light-off and are not intended as permanent pilots.
Pilot Gas PressureProvided in in water column (in wc) or ounces depending on pilot model
Mounting OptionsSide-mounted/End-mounted (for LINOFLAME and LINOPAK)
Connection TypeANSI B2.1 pipe threads
Pilot StyleAtmospheric open‑port and venturi open‑port
Mixer TypeAdjustable air-gas mixer

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
04572OPEN PORT ATMSPH PILTRequest quotation
06868OPEN PORT VENTURI PILTRequest quotation
06969OPEN PORT VENTURI PILTRequest quotation
07524SELD PILT NZLRequest quotation
09249PILT AIR SPUDRequest quotation
09250NZL BDYRequest quotation
092512.125" NZL HOODRequest quotation
09256PILT MTG BRKTRequest quotation
09300OPEN PORT PRESS PILTRequest quotation
1034044SELD PORT PRESS PILT ASY+Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pilot-burners/maxon-pilots

Last source check: 2026-11-02

Maxon Pilots Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry