Pilot Burners
Maxon Pilots
MAXON pilot selection follows the associated burner family rather than one universal pilot design.
MAXON pilot selection follows the associated burner family rather than one universal pilot design. This reference supplements individual burner catalog sections with component identifiers and performance data. It supports matching the ignition assembly to the main burner, including accessories needed for the selected fuel and control arrangement.
Features & Benefits
- Capacity
- Stated in 1,000 BTU/hr depending on assembly (varies by model)
- Ignition Gap Requirement
- 0.05 to 0.06 in for 10 or 18 mm ignitors
- Environment Limitations
- Not for outdoor or high‑draft use
- Pilot Air Requirement
- Required for premix and air-assisted pilots
- Alternative Port Type
- Sealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®)
- Burner Compatibility
- STICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME®
- Pilot Gas Pressure
- Provided in in water column (in wc) or ounces depending on pilot model
- Purge Requirement
- Full system purge before ignition
- Mounting Options
- Side-mounted/End-mounted (for LINOFLAME and LINOPAK)
- Connection Type
- ANSI B2.1 pipe threads
- Ignition Type
- Spark ignitor or gas ignitor depending on model
- Pilot Style
- Atmospheric open‑port and venturi open‑port
- Mixer Type
- Adjustable air-gas mixer
Applications
- Burner-specific MAXON pilot selection
Performance Specifications
- Capacity
- Stated in 1,000 BTU/hr depending on assembly (varies by model)
Ignition, Flame & Supervision Specifications
- Ignition Gap Requirement
- 0.05 to 0.06 in for 10 or 18 mm ignitors
- Purge Requirement
- Full system purge before ignition
- Ignition Type
- Spark ignitor or gas ignitor depending on model
Environmental Conditions
- Environment Limitations
- Not for outdoor or high‑draft use
Air & Combustion Air Specifications
- Pilot Air Requirement
- Required for premix and air-assisted pilots
Actuation, Valve & Motion Control Specifications
- Alternative Port Type
- Sealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®)
Applications & Compatibility
- Burner Compatibility
- STICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME®
- Applications
- Used for manual light-off and are not intended as permanent pilots.
Pressure Specifications
- Pilot Gas Pressure
- Provided in in water column (in wc) or ounces depending on pilot model
Installation & Mounting Specifications
- Mounting Options
- Side-mounted/End-mounted (for LINOFLAME and LINOPAK)
Connections & Interfaces
- Connection Type
- ANSI B2.1 pipe threads
Combustion, Fuel & Mixing Sub‑Systems
- Pilot Style
- Atmospheric open‑port and venturi open‑port
Mixing & Combustion Sub‑Components
- Mixer Type
- Adjustable air-gas mixer
| Parameter | Published value / configuration |
|---|---|
| Capacity | Stated in 1,000 BTU/hr depending on assembly (varies by model) |
| Ignition Gap Requirement | 0.05 to 0.06 in for 10 or 18 mm ignitors |
| Purge Requirement | Full system purge before ignition |
| Ignition Type | Spark ignitor or gas ignitor depending on model |
| Environment Limitations | Not for outdoor or high‑draft use |
| Pilot Air Requirement | Required for premix and air-assisted pilots |
| Alternative Port Type | Sealed-port (for Sealed Nozzles, WIDE‑RANGE®, MULTIFIRE®) |
| Burner Compatibility | STICKTITE™, Sealed Nozzles, SN Series, WIDE-RANGE®, MULTIFIRE®, VORTIFLARE®, LINOFLAME®, LINOPAK®, AIRFLO®, COMBUSTIFUME® |
| Applications | Used for manual light-off and are not intended as permanent pilots. |
| Pilot Gas Pressure | Provided in in water column (in wc) or ounces depending on pilot model |
| Mounting Options | Side-mounted/End-mounted (for LINOFLAME and LINOPAK) |
| Connection Type | ANSI B2.1 pipe threads |
| Pilot Style | Atmospheric open‑port and venturi open‑port |
| Mixer Type | Adjustable air-gas mixer |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 04572 | OPEN PORT ATMSPH PILT | Request quotation |
| 06868 | OPEN PORT VENTURI PILT | Request quotation |
| 06969 | OPEN PORT VENTURI PILT | Request quotation |
| 07524 | SELD PILT NZL | Request quotation |
| 09249 | PILT AIR SPUD | Request quotation |
| 09250 | NZL BDY | Request quotation |
| 09251 | 2.125" NZL HOOD | Request quotation |
| 09256 | PILT MTG BRKT | Request quotation |
| 09300 | OPEN PORT PRESS PILT | Request quotation |
| 1034044 | SELD PORT PRESS PILT ASY+ | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Maxon Pilots Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.