Ultraviolet Flame Detector C7076A,D

C7076 adjusts UV sensitivity for gas, oil and pulverized-coal flames where flame discrimination matters.

C7076 adjusts UV sensitivity for gas, oil and pulverized-coal flames where flame discrimination matters. Its output supports transmission over long wiring runs, and solid-state circuitry maintains sensing stability. C7076A addresses standard installations; the explosion-proof C7076D version is explicitly marked obsolete on the source page.

Features & Benefits

Wiring
NEC Class 1; 18 AWG, 8 ft leads; separate conduits for signal and power
Parallel Detector Capability
Up to 2 detectors per amplifier
Sensitivity Adjustment
Two independent controls (A and B), each with 400:1 dynamic range
Air Flow Requirements
Purge: 0.7 SCFM min; Recommended: 3 SCFM; Seal-off: 5 psig max
Line Voltage Options
100 VAC, 120 VAC, 220/240 VAC (±10/-15%), 50/60 Hz
Operating Principle
UV radiation detection with dynamic self-check via R7886 amplifier
Temperature Rating
Ambient: -40 to +160 deg F (-40 to +71 deg C)|Aspirator: max 225 deg F
Flame Signal Range
1.4 to 5.5 µA (detector), 0.0 to 5.0 VDC (amplifier)
Shutter Frequency
Self-check every 5 seconds (via R7886 amplifier)
Pressure Ratings
Viewing lens: max 20 psig (138 kPa)
Mounting Options
1 in NPT sight pipe; 3/8 in NPT air supply; optional swivel mount
Housing Material
Aluminum and cadmium-plated steel
Enclosure Rating
NEMA 4 (watertight and dust-tight)
Compatibility
Must be used with R7886 Dynamic Self-Check UV Amplifier
Approvals
CE Certified, SIL 3 Capable, UL Listed, UKCA Certified, RoHS Compliant, WEEE Directive 2012/19/EU
  • The signal output supports long transmission distances without special cable.

Applications

  • Gas, oil and pulverized-coal flame discrimination

Specifications

Ignition, Flame & Supervision Specifications

Wiring
NEC Class 1; 18 AWG, 8 ft leads; separate conduits for signal and power
Parallel Detector Capability
Up to 2 detectors per amplifier
Flame Signal Range
1.4 to 5.5 µA (detector), 0.0 to 5.0 VDC (amplifier)

Measurement, Accuracy & Sensing

Sensitivity Adjustment
Two independent controls (A and B), each with 400:1 dynamic range

Air & Combustion Air Specifications

Air Flow Requirements
Purge: 0.7 SCFM min; Recommended: 3 SCFM; Seal-off: 5 psig max

Electrical Specifications

Line Voltage Options
100 VAC, 120 VAC, 220/240 VAC (±10/-15%), 50/60 Hz
Shutter Frequency
Self-check every 5 seconds (via R7886 amplifier)

Control, Logic & Functional Behavior

Operating Principle
UV radiation detection with dynamic self-check via R7886 amplifier

Temperature Control/Measurement

Temperature Rating
Ambient: -40 to +160 deg F (-40 to +71 deg C); Aspirator: max 225 deg F

Pressure Specifications

Pressure Ratings
Viewing lens: max 20 psig (138 kPa)

Installation & Mounting Specifications

Mounting Options
1 in NPT sight pipe; 3/8 in NPT air supply; optional swivel mount

Material Specifications

Housing Material
Aluminum and cadmium-plated steel

Environmental Conditions

Enclosure Rating
NEMA 4 (watertight and dust-tight)

Applications & Compatibility

Compatibility
Must be used with R7886 Dynamic Self-Check UV Amplifier
Applications
Flame detection for gas, oil, and pulverized coal burners

Standards & Certifications

Approvals
CE Certified, SIL 3 Capable, UL Listed, UKCA Certified, RoHS Compliant, WEEE Directive 2012/19/EU
Ultraviolet Flame Detector C7076A,D — manufacturer page values
ParameterPublished value / configuration
WiringNEC Class 1; 18 AWG, 8 ft leads; separate conduits for signal and power
Parallel Detector CapabilityUp to 2 detectors per amplifier
Flame Signal Range1.4 to 5.5 µA (detector), 0.0 to 5.0 VDC (amplifier)
Sensitivity AdjustmentTwo independent controls (A and B), each with 400:1 dynamic range
Air Flow RequirementsPurge: 0.7 SCFM min; Recommended: 3 SCFM; Seal-off: 5 psig max
Line Voltage Options100 VAC, 120 VAC, 220/240 VAC (±10/-15%), 50/60 Hz
Shutter FrequencySelf-check every 5 seconds (via R7886 amplifier)
Operating PrincipleUV radiation detection with dynamic self-check via R7886 amplifier
Temperature RatingAmbient: -40 to +160 deg F (-40 to +71 deg C); Aspirator: max 225 deg F
Pressure RatingsViewing lens: max 20 psig (138 kPa)
Mounting Options1 in NPT sight pipe; 3/8 in NPT air supply; optional swivel mount
Housing MaterialAluminum and cadmium-plated steel
Enclosure RatingNEMA 4 (watertight and dust-tight)
CompatibilityMust be used with R7886 Dynamic Self-Check UV Amplifier
ApplicationsFlame detection for gas, oil, and pulverized coal burners
ApprovalsCE Certified, SIL 3 Capable, UL Listed, UKCA Certified, RoHS Compliant, WEEE Directive 2012/19/EU

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
114727A/XTUBINGRequest quotation
117166APOP RIVETRequest quotation
117166ACRIVETSRequest quotation
121210BFDARESISTORRequest quotation
121210CCDACARBON COMP RESISTORRequest quotation
121210CHBARESISTORRequest quotation
121210EHCARESISTORRequest quotation
121210EHDARESISTORRequest quotation
122954BGKCARESISTORRequest quotation
129156ACAPACITORRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/flame-detectors/ultraviolet-flame-detector-c7076a-d

Last source check: 2026-11-02

Ultraviolet Flame Detector · Manufacturer ownership retained; republication licence not independently confirmed

Ultraviolet Flame Detector · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry