Portable Sampling
HERMetic Samplers for Restricted Operations
HERMetic A-2 and A-4 samplers provide bottle-based sampling where the permitted operating method is restricted or open as described on the source page.
HERMetic A-2 and A-4 samplers provide bottle-based sampling where the permitted operating method is restricted or open as described on the source page. A-2 connects to two-inch valves; A-4 uses a four-inch deck valve and takes up to 1.8 litres. A graduated tape indicates depth, and alternative bottles support different sampling patterns.
Features & Benefits
- Versions
- A-2 and A-4
- A-4 capacity
- Up to 1.8 litres
Applications
- Crude-oil tanker sampling where the operating method is permitted
Detailed capabilities
Product and configuration
HERMetic A-2 and A-4 samplers provide bottle-based sampling where the permitted operating method is restricted or open as described on the source page. A-2 connects to two-inch valves; A-4 uses a four-inch deck valve and takes up to 1.8 litres. A graduated tape indicates depth, and alternative bottles support different sampling patterns.
- Versions: A-2 and A-4
- A-4 capacity: Up to 1.8 litres
Operation and integration
A-2 connects to a two-inch compact valve and A-4 to a four-inch deck valve. A sampling bottle travels vertically through the liquid on a graduated tape, viewed through the reading window. Both have zone bottles as described, with spot, bottom and running alternatives; A-4 accommodates the published larger volume up to 1.8 litres. Bottles can be removed and exchanged.
Application and selection
The page describes restricted sampling and also labels relevant operations as open, so these samplers must not be presented as sealed GT-type transfer systems. They address crude-oil sampling where that method is allowed. Valve size, bottle type and permitted operating practice determine the actual arrangement.
Standards & Certifications
- Hazardous Location Approvals
- A-2: ATEX II 1 G c IIB T6 (Zone 0), A-4: ATEX II 1 G c IIB T6 (Zone 0)
- Compliance Standards
- A-2: IMO, SOLAS, MARPOL, API, ISO, OCIMF Standards, A-4: IMO, SOLAS, MARPOL, API, ISO, OCIMF Standards
I/O Capabilities
- Sampling Principle
- A-2: For use where restricted sampling is accepted; Connects to 2 in HERMetic vapor control valves, A-4: For use where restricted sampling is accepted; Connects to 4 in HERMetic deck valve
- Sampling Capacity
- A-2: Zone sampling bottle: ~0.5 liters (spot, running, and bottom bottles available), A-4: Approx. 1.8 liters (zone, spot, running, and bottom bottles available)
Overview
- Special Features
- A-2: Multiple Bottle Types (Zone, Spot, Running, Bottom); Robust Construction Millimeter-PRD; A-4: Large Volume Sampling, Robust Construction, Multiple Bottle Types Millimeter-PRD
Environmental Conditions
- Type of Gaskets
- FKM (A-2)
Applications & Compatibility
- Typical Uses
- A-2: Custody Transfer, Inventory Control, Quality Control, Pollution Prevention on Tankers, A-4: Custody Transfer, Inventory Control, Quality Control, Pollution Prevention
- Applications
- A-2: Restricted sampling of liquids on marine vessels, A-4: Restricted sampling where more than 0.5 liters is needed
Dimensions & Weight
- Unit Height
- A-2: 802 mm, A-4: 770 mm
Network & Connectivity Infrastructure
- Tape Length
- A-2: 30 m (100 ft), A-4: 30 m (100 ft); On request: 40 m tape length
Material Specifications
- Materials
- A-2: Stainless Steel AISI 316, Brass, PTFE, PVDF, A-4: AISI 316 Stainless Steel, Rilsan Coated Aluminum
| Parameter | Published value / configuration |
|---|---|
| Hazardous Location Approvals | A-2: ATEX II 1 G c IIB T6 (Zone 0), A-4: ATEX II 1 G c IIB T6 (Zone 0) |
| Compliance Standards | A-2: IMO, SOLAS, MARPOL, API, ISO, OCIMF Standards, A-4: IMO, SOLAS, MARPOL, API, ISO, OCIMF Standards |
| Sampling Principle | A-2: For use where restricted sampling is accepted; Connects to 2 in HERMetic vapor control valves, A-4: For use where restricted sampling is accepted; Connects to 4 in HERMetic deck valve |
| Sampling Capacity | A-2: Zone sampling bottle: ~0.5 liters (spot, running, and bottom bottles available), A-4: Approx. 1.8 liters (zone, spot, running, and bottom bottles available) |
| Special Features | A-2: Multiple Bottle Types (Zone, Spot, Running, Bottom); Robust Construction Millimeter-PRD; A-4: Large Volume Sampling, Robust Construction, Multiple Bottle Types Millimeter-PRD |
| Type of Gaskets | FKM (A-2) |
| Typical Uses | A-2: Custody Transfer, Inventory Control, Quality Control, Pollution Prevention on Tankers, A-4: Custody Transfer, Inventory Control, Quality Control, Pollution Prevention |
| Applications | A-2: Restricted sampling of liquids on marine vessels, A-4: Restricted sampling where more than 0.5 liters is needed |
| Unit Height | A-2: 802 mm, A-4: 770 mm |
| Tape Length | A-2: 30 m (100 ft), A-4: 30 m (100 ft); On request: 40 m tape length |
| Materials | A-2: Stainless Steel AISI 316, Brass, PTFE, PVDF, A-4: AISI 316 Stainless Steel, Rilsan Coated Aluminum |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
8 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 10042 | HERMetic Sampler A-2 0.5 l. w/st st cont | Request quotation |
| TS 10043 | HERMetic Sampler A-4 1.8 L. w/st st cont | Request quotation |
| TS 10302 | Winder tape 30m metric/inch | Request quotation |
| TS 10308 | Winder tape 40m metric/inch | Request quotation |
| TS 20143 | TUBE | Request quotation |
| TS 20144 | Winder holder | Request quotation |
| TS 20539 | O-Ring Ø34.65x1.78 | Request quotation |
| TS 98039 | HERMetic Sampler A-2 0.5 l. 40m | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic Samplers for Restricted Operations image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic Samplers for Restricted Operations image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.