Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Sampling

HERMetic Sampler GT4 for Marine Applications

HERMetic GT4 provides larger-volume closed sampling through a four-inch deck valve.

HERMetic GT4 provides larger-volume closed sampling through a four-inch deck valve. Its bottle holds approximately 1.8 litres and is lowered on a graduated tape so crews can select depth. Honeywell supplies a zone bottle and offers spot, bottom or running alternatives, with a lower transfer valve used to move collected liquid into a laboratory container.

Features & Benefits

Capacity
Approximately 1.8 litres
Tape
30 m standard, 50 m on request
  • Supports larger samples under closed conditions

Applications

  • Marine large-volume liquid sampling

Detailed capabilities

Product and configuration

HERMetic GT4 provides larger-volume closed sampling through a four-inch deck valve. Its bottle holds approximately 1.8 litres and is lowered on a graduated tape so crews can select depth. Honeywell supplies a zone bottle and offers spot, bottom or running alternatives, with a lower transfer valve used to move collected liquid into a laboratory container.

  • Capacity: Approximately 1.8 litres
  • Tape: 30 m standard, 50 m on request

Manufacturer reference ↗

Operation and integration

The four-inch GT4 housing sits on the matching deck valve and lowers a bottle by graduated tape. A lower transfer valve releases the collected liquid into a laboratory container. The published capacity is up to 1.8 litres; thirty-metre tape is standard and fifty metres is available on request. Zone collection is standard, with other bottle types offered for different methods.

Manufacturer reference ↗

Application and selection

This arrangement addresses a larger liquid sample under closed conditions, specifically where more than half a litre is needed. The large bottle and four-inch connection distinguish it from GT1 and two-inch GT arrangements. Match the bottle type, valve and tape length to the vessel and sampling procedure.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Product Catalog - Honeywell Tanksystem for Marine Applications

View resource ↗
Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance Standards
Meets IMO, SOLAS, MARPOL, API, ISO, and OCIMF standards for marine sampling

Pressure/Operating Limits

Maximum Tank Overpressure
0.3 bar (4.4 psi)

I/O Capabilities

Sampling Principle
Bottle linked to graduated tape; Sample taken by vertical movement of bottle inside liquid
Sampling Capacity
Approx. 1.8 liters (Zone, Spot, Running, or Bottom Bottles Available)
Tape Graduation
Metric/English

Overview

Special Features
Gas-tight operation, avoids VOC emissions, compatible with large volume sampling, easy transfer to lab bottle, robust construction Millimeter-PRD

Applications & Compatibility

Typical Uses
Custody Transfer, Inventory Control, Quality Control, Pollution Prevention On Tankers
Applications
Closed, gas-tight sampling of liquids on marine vessels (fire, health, air pollution hazard)

Dimensions & Weight

Unit Height
770 mm

Network & Connectivity Infrastructure

Tape Length
Optional: up to 50 m (164 ft); Standard: 30 m (100 ft)

Material Specifications

Materials
AISI 316 Stainless Steel, Rilsan Coated Aluminum (full stainless steel on request)
HERMetic Sampler GT4 for Marine Applications — manufacturer page values
ParameterPublished value / configuration
Hazardous Location ApprovalsATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance StandardsMeets IMO, SOLAS, MARPOL, API, ISO, and OCIMF standards for marine sampling
Maximum Tank Overpressure0.3 bar (4.4 psi)
Sampling PrincipleBottle linked to graduated tape; Sample taken by vertical movement of bottle inside liquid
Sampling CapacityApprox. 1.8 liters (Zone, Spot, Running, or Bottom Bottles Available)
Tape GraduationMetric/English
Special FeaturesGas-tight operation, avoids VOC emissions, compatible with large volume sampling, easy transfer to lab bottle, robust construction Millimeter-PRD
Typical UsesCustody Transfer, Inventory Control, Quality Control, Pollution Prevention On Tankers
ApplicationsClosed, gas-tight sampling of liquids on marine vessels (fire, health, air pollution hazard)
Unit Height770 mm
Tape LengthOptional: up to 50 m (164 ft); Standard: 30 m (100 ft)
MaterialsAISI 316 Stainless Steel, Rilsan Coated Aluminum (full stainless steel on request)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
TS 10033HERMetic Sampler GT4Request quotation
TS 12041WiperRequest quotation
TS 12042Spring for wiper PTFERequest quotation
TS 12043Wiper holderRequest quotation
TS 20022Push buttonRequest quotation
TS 20023Axle of wiperRequest quotation
TS 20024Frame of sightglassRequest quotation
TS 20050Bottom valveRequest quotation
TS 20051Valve screwRequest quotation
TS 20099TubeRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/portable-sampling/hermetic-sampler-gt4-for-marine-applications

Last source check: 2026-11-02

HERMetic Sampler GT4 image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler GT4 image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.