Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Sampling

HERMetic Sampler GT1 for Marine Applications

HERMetic GT1 takes liquid samples through a one-inch quick-connected deck valve.

HERMetic GT1 takes liquid samples through a one-inch quick-connected deck valve. Its gas-tight housing contains a bottle of approximately 0.3 litre, with depth read from the graduated tape. A transfer valve releases collected liquid into a laboratory bottle, and optional spot, bottom or running bottles adapt the standard zone-sampling arrangement to other collection requirements.

Features & Benefits

Capacity
Approximately 0.3 litre
Connection
1-inch quick coupling
  • Limits vapor exposure during sample collection

Applications

  • Closed marine liquid sampling

Detailed capabilities

Product and configuration

HERMetic GT1 takes liquid samples through a one-inch quick-connected deck valve. Its gas-tight housing contains a bottle of approximately 0.3 litre, with depth read from the graduated tape. A transfer valve releases collected liquid into a laboratory bottle, and optional spot, bottom or running bottles adapt the standard zone-sampling arrangement to other collection requirements.

  • Capacity: Approximately 0.3 litre
  • Connection: 1-inch quick coupling

Manufacturer reference ↗

Operation and integration

GT1 uses a one-inch quick-coupled deck-valve connection and a removable sampling bottle lowered on a thirty-metre graduated tape. Its nominal 0.3 litre bottle fits within the portable gas-tight housing. After collection, the lower transfer valve moves liquid into the laboratory bottle; opening the housing top allows the sampling bottle to be exchanged.

Manufacturer reference ↗

Application and selection

The standard bottle collects a zone sample, with spot, bottom and running alternatives available by request. The source associates the configuration with closed sampling and published marine/construction-safety references. Select the collection method and quantity for the analytical task rather than treating the default zone bottle as representative of every tank-sampling requirement.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Applications & Compatibility

Applications
Closed, gas-tight sampling of liquids on marine vessels and tank farms (avoids fire, health, air pollution hazard)
Typical Uses
Custody Transfer, Inventory Control, Quality Control, Pollution Prevention On Tankers

Dimensions & Weight

Unit Height
1260 mm

Environmental Conditions

Type of Gaskets
FKM

Network & Connectivity Infrastructure

Tape Length
30 m/100 ft

I/O Capabilities

Tank Connection
Easy installation on 1 in HERMetic vapor control valves with a quick connect coupling
Sampling Principle
Designed for closed sampling to prevent vapor emission and pressure release; Gas-tight housing
Sampling Capacity
Zone Sampling Bottle: approx. 0.3 liters (spot, running, and bottom bottles available)

Overview

Special Features
Gas-tight operation, prevents vapor emission, robust construction, easy bottle removal Millimeter-PRD

Pressure/Operating Limits

Maximum Tank Overpressure
Designed for marine closed sampling applications

Material Specifications

Materials
Stainless Steel AISI 316, Brass, PTFE, PVDF

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance Standards
Meets IMO, SOLAS, MARPOL, API, ISO, and OCIMF standards for marine sampling
HERMetic Sampler GT1 for Marine Applications — manufacturer page values
ParameterPublished value / configuration
ApplicationsClosed, gas-tight sampling of liquids on marine vessels and tank farms (avoids fire, health, air pollution hazard)
Typical UsesCustody Transfer, Inventory Control, Quality Control, Pollution Prevention On Tankers
Unit Height1260 mm
Type of GasketsFKM
Tape Length30 m/100 ft
Tank ConnectionEasy installation on 1 in HERMetic vapor control valves with a quick connect coupling
Sampling PrincipleDesigned for closed sampling to prevent vapor emission and pressure release; Gas-tight housing
Sampling CapacityZone Sampling Bottle: approx. 0.3 liters (spot, running, and bottom bottles available)
Special FeaturesGas-tight operation, prevents vapor emission, robust construction, easy bottle removal Millimeter-PRD
Maximum Tank OverpressureDesigned for marine closed sampling applications
MaterialsStainless Steel AISI 316, Brass, PTFE, PVDF
Hazardous Location ApprovalsATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance StandardsMeets IMO, SOLAS, MARPOL, API, ISO, and OCIMF standards for marine sampling

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

4 parts

Part NumberDescriptionEnquiry
TS 10084HERMetic Sampler GT1Request quotation
TS 20140Storage tubeRequest quotation
TS 20152Elbow Ø6 mmRequest quotation
TS 98166HERMetic sampler GT1 35 mRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/portable-sampling/hermetic-sampler-gt1-for-marine-applications

Last source check: 2026-11-02

HERMetic Sampler GT1 image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler GT1 image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.