Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Sampling

HERMetic Sampler GTN for Marine Applications

GTN Chem keeps both collection and transfer closed when a liquid sample must avoid atmospheric contact.

GTN Chem keeps both collection and transfer closed when a liquid sample must avoid atmospheric contact. The portable sampler attaches to two-inch HERMetic valves and transfers into a septum-sealed laboratory bottle, returning displaced vapors to the tank. Interchangeable bottles provide several sampling methods for clean chemicals or refined products requiring protected sample integrity.

Features & Benefits

Transfer
Closed transfer into a septum-sealed bottle
Vapor handling
Recovery to tank
  • Preserves samples from atmospheric contact

Applications

  • Clean chemicals and refined products
  • Closed marine sampling

Detailed capabilities

Product and configuration

GTN Chem keeps both collection and transfer closed when a liquid sample must avoid atmospheric contact. The portable sampler attaches to two-inch HERMetic valves and transfers into a septum-sealed laboratory bottle, returning displaced vapors to the tank. Interchangeable bottles provide several sampling methods for clean chemicals or refined products requiring protected sample integrity.

  • Transfer: Closed transfer into a septum-sealed bottle
  • Vapor handling: Recovery to tank

Manufacturer reference ↗

Operation and integration

GTN Chem connects exclusively to two-inch HERMetic compact valves and transfers into a septum-sealed laboratory bottle without exposing the sample to air. A vapor-recovery path returns displaced gas to the tank during transfer. The graduated tape locates the sample, and alternate bottle designs support zone, spot, running or bottom collection while maintaining the described closed system.

Manufacturer reference ↗

Application and selection

The published limits include 0.3 bar tank overpressure, a thirty-metre tape and approximately 0.5 litre bottle capacity. The key distinction is protection of the liquid from atmospheric alteration, especially for clean chemicals or refined products. Maintaining the sealed transfer path is therefore part of the sampling purpose, not merely a convenience during handling.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Product Catalog - Honeywell Tanksystem for Marine Applications

View resource ↗
Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance Standards
Meets ISO 3170, API MPMS Chap 8.1, API MPMS Chap 17.11

Pressure/Operating Limits

Maximum Tank Overpressure
0.3 bar (4.4 psi)

I/O Capabilities

Sampling Principle
Gas-tight construction; Sample transferred under closed conditions to maintain integrity
Sampling Capacity
Laboratory bottle: 0.47 liters (16 oz); Sampling bottle: approx. 0.5 liters

Overview

Special Features
Gas-tight operation, closed vapor recovery, inert gas purging, easy sample transfer, robust construction Millimeter-PRD

Applications & Compatibility

Typical Uses
Custody Transfer, Inventory Control, Quality Control, Pollution Prevention
Applications
Closed, gas-tight sampling of chemicals and hazardous liquids on marine vessels and tank farms

Dimensions & Weight

Unit Height
801 mm

Network & Connectivity Infrastructure

Tape Length
30 m/100 ft

Material Specifications

Materials
FFKM Gaskets; Stainless Steel AISI 316, PTFE, PVDF
HERMetic Sampler GTN for Marine Applications — manufacturer page values
ParameterPublished value / configuration
Hazardous Location ApprovalsATEX II 1 G c IIB T6 (suitable for Zone 0 hazardous environments)
Compliance StandardsMeets ISO 3170, API MPMS Chap 8.1, API MPMS Chap 17.11
Maximum Tank Overpressure0.3 bar (4.4 psi)
Sampling PrincipleGas-tight construction; Sample transferred under closed conditions to maintain integrity
Sampling CapacityLaboratory bottle: 0.47 liters (16 oz); Sampling bottle: approx. 0.5 liters
Special FeaturesGas-tight operation, closed vapor recovery, inert gas purging, easy sample transfer, robust construction Millimeter-PRD
Typical UsesCustody Transfer, Inventory Control, Quality Control, Pollution Prevention
ApplicationsClosed, gas-tight sampling of chemicals and hazardous liquids on marine vessels and tank farms
Unit Height801 mm
Tape Length30 m/100 ft
MaterialsFFKM Gaskets; Stainless Steel AISI 316, PTFE, PVDF

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
TS 10087HERMetic Sampler GTN Chem incl. caseRequest quotation
TS 10417Valve and bottle holder assyRequest quotation
TS 14143Omniseal 103A Ø6.05x1.78Request quotation
TS 20054Finger for bottle holderRequest quotation
TS 20056Spring for bottle/holderRequest quotation
TS 20150Parallel nipple G1/8''Request quotation
TS 20153Special muff G 1/4''Request quotation
TS 20154Screw M6 specialRequest quotation
TS 20158Bend needle 16 GaRequest quotation
TS 20159Ferrule SwagelockRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/portable-sampling/hermetic-sampler-gtn-for-marine-applications

Last source check: 2026-11-02

HERMetic Sampler GTN Chem image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler GTN Chem Image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler GTN Chem image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler GTN Chem image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.