HON 658-EP combines electronic gas control with pneumatic stages that enforce preset pressure limits.
HON 658-EP combines electronic gas control with pneumatic stages that enforce preset pressure limits. Within those bounds it supports remote setpoints, flow regulation and scheduled pressure curves. As outlet pressure approaches a boundary, the pneumatic stage takes over automatically, allowing electronic and pneumatic functions to work together in the same regulating arrangement.
Models: HON 658-EP
Features & Benefits
- Control
- Electronic with pneumatic pressure limits
- Automatic transfer supports continuous pressure control
Applications
- Gas network storage, flow limitation and process-control integration
Detailed capabilities
HON 658-EP — operating design
HON 658-EP combines electronic gas control with pneumatic stages that enforce preset pressure limits. Within those bounds it supports remote setpoints, flow regulation and scheduled pressure curves. As outlet pressure approaches a boundary, the pneumatic stage takes over automatically, allowing electronic and pneumatic functions to work together in the same regulating arrangement.
Four-stage bounded control
HON 658-EP uses automatic load limiting, separate lower and upper outlet control stages and an electro-pneumatic loading stage. The electronic controller works within pneumatic limits, with automatic takeover near either boundary. Remote setpoints, day/week pressure schedules, flow limiting and network storage are published modes, and the source identifies electronic PI/PID operation for improved control stability.
Published configuration and technical facts
The manufacturer lists these values for HON 658-EP. Version, size and option qualifications remain attached to each fact.
- Maximum Admissible Pressure: 100 bar
- Inlet Pressure Range: 100 bar
- Auxiliary Energy: 24 VDC, max. 1.5 A (for HON 110a modulator)
- Approvals: CE Mark with PED, DIN EN 334
- Output Signal: Pulse Signal 24 Vss, Short Circuit-Proof
- Input Signal: 0/4 to 20 mA or 0 to 10 V
Processing & Performance Metrics
- Maximum Admissible Pressure
- 100 bar
Environmental Conditions
- Inlet Pressure Range
- 100 bar
- Auxiliary Energy
- 24 VDC, max. 1.5 A (for HON 110a modulator)
Standards & Certifications
- Explosion Protection
- All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
- Approvals
- CE Mark with PED, DIN EN 334
Electrical Specifications
- Output Signal
- Pulse Signal 24 Vss, Short Circuit-Proof
- Input Signal
- 0/4 to 20 mA or 0 to 10 V
| Parameter | Published value / configuration |
|---|---|
| Maximum Admissible Pressure | 100 bar |
| Inlet Pressure Range | 100 bar |
| Auxiliary Energy | 24 VDC, max. 1.5 A (for HON 110a modulator) |
| Explosion Protection | All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements. |
| Approvals | CE Mark with PED, DIN EN 334 |
| Output Signal | Pulse Signal 24 Vss, Short Circuit-Proof |
| Input Signal | 0/4 to 20 mA or 0 to 10 V |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
HON 658-EP Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.