Pilot for Gas Pressure Regulators
HON 630-FE
HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot.
HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot. Operators can change the setting from a control room or manually at the electric actuator. The arrangement is intended for stations needing variable outlet pressure, and an optional vent valve supports additional system configurations within the published pressure envelope.
Models: HON 630-FE
Features & Benefits
- Maximum admissible pressure
- 100 bar
- Outlet range
- 0.3–90 bar
- Adjustment
- Electric remote or manual at actuator
- Allows control-room setpoint changes
Applications
- Stations with variable gas outlet pressure
Detailed capabilities
HON 630-FE — operating design
HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot. Operators can change the setting from a control room or manually at the electric actuator. The arrangement is intended for stations needing variable outlet pressure, and an optional vent valve supports additional system configurations within the published pressure envelope.
Remote and local adjustment
An electric actuator sets the pilot from a control room, while manual adjustment remains possible at the actuator. The source names a drive-shaft interface and provides motor and electrical details on enquiry rather than publishing one universal supply. An optional HON 915 vent and the compatible regulator configuration complete the assembly for variable outlet-pressure stations.
Published configuration and technical facts
The manufacturer lists these values for HON 630-FE. Version, size and option qualifications remain attached to each fact.
- Maximum Admissible Pressure: 100 bar
- Lock-up Pressure Zone Class: SZ 2.5
- Outlet Pressure Range: Wd: 0.3 to 90 bar
- Inlet Pressure Range: 100 bar
- Temperature Range: -20 to +60 deg C (Class 2)
- Approvals: CE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334
- Connection Type: Pipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes)
Processing & Performance Metrics
- Maximum Admissible Pressure
- 100 bar
- Accuracy Class (AC)
- AC 20 (0.15 to 1 bar), AC 10 (>1 to 3 bar), AC 5 (>3 to 5 bar), AC 2.5 (>5 to 90 bar)
Mechanical & Physical Properties
- Lock-up Pressure Zone Class
- SZ 2.5
Environmental Conditions
- Outlet Pressure Range
- Wd: 0.3 to 90 bar
- Inlet Pressure Range
- 100 bar
- Temperature Range
- -20 to +60 deg C (Class 2)
Standards & Certifications
- Explosion Protection
- All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
- Approvals
- CE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334
Overview
- Special Features
- Provided with electric remote setpoint adjustment Millimeter-PRD
Technical Specifications
- Connection Type
- Pipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes)
Material Specifications
- Body Material
- Aluminum Alloy
Applications & Compatibility
- Applications
- Pilot for gas pressure regulators HON 402, HON 502, HON 503, HON 5020; Suitable for natural gas and all non-corrosive gaseous media; Suitable for natural gas and all non-corrosive gaseous media
| Parameter | Published value / configuration |
|---|---|
| Maximum Admissible Pressure | 100 bar |
| Accuracy Class (AC) | AC 20 (0.15 to 1 bar), AC 10 (>1 to 3 bar), AC 5 (>3 to 5 bar), AC 2.5 (>5 to 90 bar) |
| Lock-up Pressure Zone Class | SZ 2.5 |
| Outlet Pressure Range | Wd: 0.3 to 90 bar |
| Inlet Pressure Range | 100 bar |
| Temperature Range | -20 to +60 deg C (Class 2) |
| Explosion Protection | All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements. |
| Approvals | CE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334 |
| Special Features | Provided with electric remote setpoint adjustment Millimeter-PRD |
| Connection Type | Pipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes) |
| Body Material | Aluminum Alloy |
| Applications | Pilot for gas pressure regulators HON 402, HON 502, HON 503, HON 5020; Suitable for natural gas and all non-corrosive gaseous media; Suitable for natural gas and all non-corrosive gaseous media |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HON635 | Pilot HON 635 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HON 630-FE Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.