Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pilot for Gas Pressure Regulators

HON 630-FE

HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot.

HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot. Operators can change the setting from a control room or manually at the electric actuator. The arrangement is intended for stations needing variable outlet pressure, and an optional vent valve supports additional system configurations within the published pressure envelope.

Models: HON 630-FE

Features & Benefits

Maximum admissible pressure
100 bar
Outlet range
0.3–90 bar
Adjustment
Electric remote or manual at actuator
  • Allows control-room setpoint changes

Applications

  • Stations with variable gas outlet pressure

Detailed capabilities

HON 630-FE — operating design

HON 630-FE adds electrical remote setpoint adjustment to a pneumatic gas regulator pilot. Operators can change the setting from a control room or manually at the electric actuator. The arrangement is intended for stations needing variable outlet pressure, and an optional vent valve supports additional system configurations within the published pressure envelope.

Manufacturer reference ↗

Remote and local adjustment

An electric actuator sets the pilot from a control room, while manual adjustment remains possible at the actuator. The source names a drive-shaft interface and provides motor and electrical details on enquiry rather than publishing one universal supply. An optional HON 915 vent and the compatible regulator configuration complete the assembly for variable outlet-pressure stations.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 630-FE. Version, size and option qualifications remain attached to each fact.

  • Maximum Admissible Pressure: 100 bar
  • Lock-up Pressure Zone Class: SZ 2.5
  • Outlet Pressure Range: Wd: 0.3 to 90 bar
  • Inlet Pressure Range: 100 bar
  • Temperature Range: -20 to +60 deg C (Class 2)
  • Approvals: CE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334
  • Connection Type: Pipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes)

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Maximum Admissible Pressure
100 bar
Accuracy Class (AC)
AC 20 (0.15 to 1 bar), AC 10 (>1 to 3 bar), AC 5 (>3 to 5 bar), AC 2.5 (>5 to 90 bar)

Mechanical & Physical Properties

Lock-up Pressure Zone Class
SZ 2.5

Environmental Conditions

Outlet Pressure Range
Wd: 0.3 to 90 bar
Inlet Pressure Range
100 bar
Temperature Range
-20 to +60 deg C (Class 2)

Standards & Certifications

Explosion Protection
All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
Approvals
CE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334

Overview

Special Features
Provided with electric remote setpoint adjustment Millimeter-PRD

Technical Specifications

Connection Type
Pipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes)

Material Specifications

Body Material
Aluminum Alloy

Applications & Compatibility

Applications
Pilot for gas pressure regulators HON 402, HON 502, HON 503, HON 5020; Suitable for natural gas and all non-corrosive gaseous media; Suitable for natural gas and all non-corrosive gaseous media
HON 630-FE — manufacturer page values
ParameterPublished value / configuration
Maximum Admissible Pressure100 bar
Accuracy Class (AC)AC 20 (0.15 to 1 bar), AC 10 (>1 to 3 bar), AC 5 (>3 to 5 bar), AC 2.5 (>5 to 90 bar)
Lock-up Pressure Zone ClassSZ 2.5
Outlet Pressure RangeWd: 0.3 to 90 bar
Inlet Pressure Range100 bar
Temperature Range-20 to +60 deg C (Class 2)
Explosion ProtectionAll mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
ApprovalsCE Mark with PED, DIN-DVGW Registration, Function and Strength per EN 334
Special FeaturesProvided with electric remote setpoint adjustment Millimeter-PRD
Connection TypePipe Connections (DIN EN ISO 8434-1/DIN 2353): Measuring Line, Discharge Line, Vent Line, Inlet Pressure, Loading Pressure (various sizes)
Body MaterialAluminum Alloy
ApplicationsPilot for gas pressure regulators HON 402, HON 502, HON 503, HON 5020; Suitable for natural gas and all non-corrosive gaseous media; Suitable for natural gas and all non-corrosive gaseous media

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType
HON 630 ↗2026-11-02PDF

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

1 parts

Part NumberDescriptionEnquiry
HON635Pilot HON 635Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/pilot-for-gas-pressure-regulators/hon-630-fe

Last source check: 2026-11-02

HON 630-FE Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry