Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pilot for Gas Pressure Regulators

HON 658-DP

HON 658-DP uses independently set lower and upper outlet-pressure stages around a differential-pressure control stage.

HON 658-DP uses independently set lower and upper outlet-pressure stages around a differential-pressure control stage. Control transfers automatically between these functions as conditions change. Its modular arrangement includes load limiting, gauges and an upstream fine filter, with optional outlet gauging and venting to suit the gas regulating station.

Models: HON 658-DP

Features & Benefits

Stages
Lower outlet limit, upper outlet limit and differential pressure
Transition
Automatic
  • Controls differential pressure within independently set outlet limits

Applications

  • Gas pressure and differential-pressure control

Detailed capabilities

HON 658-DP — operating design

HON 658-DP uses independently set lower and upper outlet-pressure stages around a differential-pressure control stage. Control transfers automatically between these functions as conditions change. Its modular arrangement includes load limiting, gauges and an upstream fine filter, with optional outlet gauging and venting to suit the gas regulating station.

Manufacturer reference ↗

Independent pressure limits and differential control

Two outlet stages are set independently to a low and a high boundary, with a differential stage operating between them. Automatic transfer links these functions with modular load limiting. The source lists 0.3–90 bar for each outlet stage, 0.05–1.2 bar for differential pressure and loading 0.5–15 bar above the outlet, keeping those quantities distinct.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 658-DP. Version, size and option qualifications remain attached to each fact.

  • Maximum Admissible Pressure: 100 bar
  • Differential Pressure Range: 0.05 to 1.2 bar
  • Outlet Pressure Range: Wd: 0.3 to 90 bar
  • Inlet Pressure Range: 100 bar
  • Auxiliary Energy: 24 VDC, max. 1.5 A (for HON 110a modulator)
  • Approvals: CE Mark with PED, DIN EN 334
  • Load-Limiting Stage: 0.5 to 15 bar
  • Output Signal: Pulse Signal 24 Vss, Short Circuit-Proof
  • Input Signal: 0/4 to 20 mA or 0 to 10 V

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Maximum Admissible Pressure
100 bar

Technical Specifications

Differential Pressure Range
0.05 to 1.2 bar

Environmental Conditions

Outlet Pressure Range
Wd: 0.3 to 90 bar
Inlet Pressure Range
100 bar
Auxiliary Energy
24 VDC, max. 1.5 A (for HON 110a modulator)

Standards & Certifications

Explosion Protection
All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
Approvals
CE Mark with PED, DIN EN 334

Mechanical & Physical Properties

Load-Limiting Stage
0.5 to 15 bar

Electrical Specifications

Output Signal
Pulse Signal 24 Vss, Short Circuit-Proof
Input Signal
0/4 to 20 mA or 0 to 10 V

Applications & Compatibility

Applications
Pilot for gas pressure regulators. Suitable for non-aggressive gases, other gases on enquiry
HON 658-DP — manufacturer page values
ParameterPublished value / configuration
Maximum Admissible Pressure100 bar
Differential Pressure Range0.05 to 1.2 bar
Outlet Pressure RangeWd: 0.3 to 90 bar
Inlet Pressure Range100 bar
Auxiliary Energy24 VDC, max. 1.5 A (for HON 110a modulator)
Explosion ProtectionAll mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
ApprovalsCE Mark with PED, DIN EN 334
Load-Limiting Stage0.5 to 15 bar
Output SignalPulse Signal 24 Vss, Short Circuit-Proof
Input Signal0/4 to 20 mA or 0 to 10 V
ApplicationsPilot for gas pressure regulators. Suitable for non-aggressive gases, other gases on enquiry

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

1 parts

Part NumberDescriptionEnquiry
HON658Pilot HON 658Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/pilot-for-gas-pressure-regulators/hon-658-dp

Last source check: 2026-11-02

HON 658-DP Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry