Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

High Pressure Regulators up to ANSI 600

HON 503

HON 503 combines pilot-operated pressure regulation with an integrated safety shut-off valve.

HON 503 combines pilot-operated pressure regulation with an integrated safety shut-off valve. It is intended for non-aggressive gases at transfer stations and industrial installations. The enlarged outlet and noise-control arrangement support the regulating duty, while the selected shut-off actuator determines the applicable overpressure and underpressure release settings.

Models: HON 503

Features & Benefits

Maximum admissible pressure
100 bar
Outlet pressure range
0.3–90 bar
Protection
Integrated safety shut-off valve
  • Simplifies maintenance with fewer parts

Applications

  • Gas transmission transfer stations and industrial gas supply

Detailed capabilities

HON 503 — operating design

HON 503 combines pilot-operated pressure regulation with an integrated safety shut-off valve. It is intended for non-aggressive gases at transfer stations and industrial installations. The enlarged outlet and noise-control arrangement support the regulating duty, while the selected shut-off actuator determines the applicable overpressure and underpressure release settings.

Manufacturer reference ↗

Integrated shut-off configuration

HON 503 adds a safety shut-off unit to the pilot-regulated pressure reducer. Actuator choices cover several measuring systems and pressure settings; overpressure and underpressure limits must therefore follow the selected actuator. The enlarged outlet and grid support quiet operation, while an optional metal-foam arrangement adds attenuation. The source preserves distinct admissible pressure, inlet pressure and pressure-drop limits.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 503. Version, size and option qualifications remain attached to each fact.

  • Minimum Differential Pressure: Δp min = 2.0 bar (Δp min = 4.0 bar at DN 25/25)
  • Maximum Inlet Pressure Rating: 100 bar
  • Connection Type: DIN PN 40 Flange, ANSI 150 (DN 25/25 only), ANSI 300, ANSI 600
  • Maximum Pressure Difference: Δp max = 70 bar
  • Closing Pressure Category: SZ 2.5
  • Outlet Pressure Range: 0.3 to 40 bar (with pilot HON 630, Two-Stage), 20 to 90 bar (with Metal Harmonica Measuring Unit)
  • Temperature Range: -20 to +60 deg C
  • Explosion Protection: Not subject to ATEX 95 (no ignition sources)

Manufacturer reference ↗

Specifications

Technical Specifications

Minimum Differential Pressure
Δp min = 2.0 bar (Δp min = 4.0 bar at DN 25/25)
Maximum Inlet Pressure Rating
100 bar
Connection Type
DIN PN 40 Flange, ANSI 150 (DN 25/25 only), ANSI 300, ANSI 600

Processing & Performance Metrics

Maximum Pressure Difference
Δp max = 70 bar

Environmental Conditions

Closing Pressure Category
SZ 2.5
Outlet Pressure Range
0.3 to 40 bar (with pilot HON 630, Two-Stage), 20 to 90 bar (with Metal Harmonica Measuring Unit)
Temperature Range
-20 to +60 deg C

Standards & Certifications

Explosion Protection
Not subject to ATEX 95 (no ignition sources)
Approvals
CE Mark with PED

Material Specifications

Body Material
Cast Steel Actuator

Applications & Compatibility

Applications
Local use at power plants, industrial facilities; Suitable for natural gas and non-aggressive gases
HON 503 — manufacturer page values
ParameterPublished value / configuration
Minimum Differential PressureΔp min = 2.0 bar (Δp min = 4.0 bar at DN 25/25)
Maximum Inlet Pressure Rating100 bar
Connection TypeDIN PN 40 Flange, ANSI 150 (DN 25/25 only), ANSI 300, ANSI 600
Maximum Pressure DifferenceΔp max = 70 bar
Closing Pressure CategorySZ 2.5
Outlet Pressure Range0.3 to 40 bar (with pilot HON 630, Two-Stage), 20 to 90 bar (with Metal Harmonica Measuring Unit)
Temperature Range-20 to +60 deg C
Explosion ProtectionNot subject to ATEX 95 (no ignition sources)
ApprovalsCE Mark with PED
Body MaterialCast Steel Actuator
ApplicationsLocal use at power plants, industrial facilities; Suitable for natural gas and non-aggressive gases

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

3 parts

Part NumberDescriptionEnquiry
BD580SERIES 580 WAFERCHEK NON-RETURN VALVERequest quotation
BD585SERIES 585 STREAMCHEK NON-RETURN VALVERequest quotation
HON503Gas pressure Regulator HON 503Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/high-pressure-regulators-up-to-ansi-600/hon-503

Last source check: 2026-11-02

HON 503 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry