HON 925 protects connected gas measuring equipment from overpressure.
HON 925 protects connected gas measuring equipment from overpressure. The compact device is offered with fixed response settings and an additional connection for a pilot's measuring or impulse line. Different inlet and gauge connections are published, allowing the selected version to match the instrument piping without treating all settings as interchangeable.
Models: HON 925
Features & Benefits
- Maximum admissible pressure
- 100 bar
- Response settings
- Fixed values from 0.6 to 40 bar listed, others on enquiry
- Compact protection arrangement
Applications
- Gas pressure measurement and pilot impulse lines
Detailed capabilities
HON 925 — operating design
HON 925 protects connected gas measuring equipment from overpressure. The compact device is offered with fixed response settings and an additional connection for a pilot's measuring or impulse line. Different inlet and gauge connections are published, allowing the selected version to match the instrument piping without treating all settings as interchangeable.
Fixed trip settings and instrument connections
HON 925 is supplied with selected fixed response pressures, from the manufacturer’s listed low setting through the higher ranges. An extra impulse connection supports the pilot measurement line. Inlet tubing options and the gauge-side connection differ, so the protector must be matched to both the chosen trip pressure and the connected measuring equipment.
Published configuration and technical facts
The manufacturer lists these values for HON 925. Version, size and option qualifications remain attached to each fact.
- Maximum Admissible Pressure: 100 bar
- Maximum Operating Pressure: up to 100 bar kilopascal
Processing & Performance Metrics
- Maximum Admissible Pressure
- 100 bar
Environmental Conditions
- Maximum Operating Pressure
- up to 100 bar kilopascal
Standards & Certifications
- Explosion Protection
- All mechanical components of this device are without ignition sources. As such, they are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfil the ATEX requirements.
- Approvals
- DVGW Registration, SEP Design According to PED
Technical Specifications
- Connection Type
- Inlet: Pipe Connection DIN EN ISO 8434-1 (DIN 2353) for Pipe Sizes 10 mm, 12 mm; Outlet: Gauge Connection According to DIN EN ISO 228 G 1/4 - or similar to pipe connection
Applications & Compatibility
- Applications
- Suitable for non-aggressive gases, other gases on enquiry
| Parameter | Published value / configuration |
|---|---|
| Maximum Admissible Pressure | 100 bar |
| Maximum Operating Pressure | up to 100 bar kilopascal |
| Explosion Protection | All mechanical components of this device are without ignition sources. As such, they are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfil the ATEX requirements. |
| Approvals | DVGW Registration, SEP Design According to PED |
| Connection Type | Inlet: Pipe Connection DIN EN ISO 8434-1 (DIN 2353) for Pipe Sizes 10 mm, 12 mm; Outlet: Gauge Connection According to DIN EN ISO 228 G 1/4 - or similar to pipe connection |
| Applications | Suitable for non-aggressive gases, other gases on enquiry |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HON925 | Overpressure shut off valve HON 925 | Request quotation |
| RMG925 | Overpressure shut off valve RMG 925 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HON 925 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.