Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Gas Filters, Valves & Components

HON 906 and 906a

HON 906 and HON 906a remove dust, rust and other solids ahead of gas regulation and metering equipment.

HON 906 and HON 906a remove dust, rust and other solids ahead of gas regulation and metering equipment. Their replaceable pleated-paper inserts are offered in several filtration grades. HON 906a adds two-stage dust separation and an optional magnetic insert, while pressure and connection selections vary between versions.

Models: HON 906 and 906a

Features & Benefits

Filter grades
10, 4 or 2 μm
HON 906 maximum admissible pressure
16 bar
HON 906a maximum admissible pressure
25 bar
  • Low pressure loss and replaceable filtration inserts

Applications

  • Distribution stations, power plants and industrial facilities

Detailed capabilities

HON 906 and 906a — operating design

HON 906 and HON 906a remove dust, rust and other solids ahead of gas regulation and metering equipment. Their replaceable pleated-paper inserts are offered in several filtration grades. HON 906a adds two-stage dust separation and an optional magnetic insert, while pressure and connection selections vary between versions.

Manufacturer reference ↗

HON 906 compared with HON 906a

The basic HON 906 uses replaceable pleated-paper filtration in several grades and sizes. HON 906a adds two-stage dust separation and an optional magnetic insert; the t version is identified for increased thermal resilience. Their permissible pressures differ, while body material and flange size also depend on the selected diameter. Cleaning and disposal are therefore tied to the appropriate insert, not one common cartridge across the range.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 906 and 906a. Version, size and option qualifications remain attached to each fact.

  • Maximum Permissible Pressure: HON 906: 16 bar, HON 906a: 25 bar
  • Maximum Flow Velocity: 20 m/s
  • Soiled Filter Insert Limit: 500 mbar
  • Connection Type: ANSI Flanges Class 150 RF; EN Flanges PN 16, PN 25
  • Filtration Efficiency: 0.99
  • Temperature Range: -20 to +60 deg C
  • Approvals: DIN 3386, DVGW G 498, DIN 30690-1, CE Marked PED 0085, ATEX 95 (94/9/EC)
  • Body Material: Cast Aluminum Alloy (HON 906 DN 25-100, HON 907 all DN), Ductile Iron (HON 906 DN 150, HON 906a)
  • Nominal Widths: DN 25 to 150

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Maximum Permissible Pressure
HON 906: 16 bar, HON 906a: 25 bar
Maximum Flow Velocity
20 m/s

Technical Specifications

Soiled Filter Insert Limit
500 mbar
Connection Type
ANSI Flanges Class 150 RF; EN Flanges PN 16, PN 25

Environmental Conditions

Filtration Efficiency
0.99
Temperature Range
-20 to +60 deg C

Standards & Certifications

Explosion Protection
All mechanical components of this device are without ignition sources. As such, they are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfil the ATEX requirements.
Approvals
DIN 3386, DVGW G 498, DIN 30690-1, CE Marked PED 0085, ATEX 95 (94/9/EC)

Material Specifications

Filter Material
Pleated Special Paper
Body Material
Cast Aluminum Alloy (HON 906 DN 25-100, HON 907 all DN), Ductile Iron (HON 906 DN 150, HON 906a)

Electrical Specifications

Nominal Widths
DN 25 to 150

Applications & Compatibility

Applications
Gas filter for commercial and industrial gas systems; Gases per DVGW G 260; Neutral, non-aggressive gases
HON 906 and 906a — manufacturer page values
ParameterPublished value / configuration
Maximum Permissible PressureHON 906: 16 bar, HON 906a: 25 bar
Maximum Flow Velocity20 m/s
Soiled Filter Insert Limit500 mbar
Connection TypeANSI Flanges Class 150 RF; EN Flanges PN 16, PN 25
Filtration Efficiency0.99
Temperature Range-20 to +60 deg C
Explosion ProtectionAll mechanical components of this device are without ignition sources. As such, they are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfil the ATEX requirements.
ApprovalsDIN 3386, DVGW G 498, DIN 30690-1, CE Marked PED 0085, ATEX 95 (94/9/EC)
Filter MaterialPleated Special Paper
Body MaterialCast Aluminum Alloy (HON 906 DN 25-100, HON 907 all DN), Ductile Iron (HON 906 DN 150, HON 906a)
Nominal WidthsDN 25 to 150
ApplicationsGas filter for commercial and industrial gas systems; Gases per DVGW G 260; Neutral, non-aggressive gases

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

HON 906 and 906aRequest quotation ›

Published part numbers

3 parts

Part NumberDescriptionEnquiry
HON906Gas Filter HON 906Request quotation
HON906AGas Filter HON 906aRequest quotation
HON906_PAGas Filter HON 906 Pre-assemblyRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/gas-filters-valves-and-components/hon-906-and-906a

Last source check: 2026-11-02

HON 906 and 906a Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.