Dataloggers & Pressure Recorders
SIP-CB Data Logger
SIP-CB combines four pulse-counting channels with a GSM/GPRS modem to send interval readings to supported meter data systems.
SIP-CB combines four pulse-counting channels with a GSM/GPRS modem to send interval readings to supported meter data systems. Pulse channels can alternatively monitor status, alongside four dedicated alarm inputs. The logger can call immediately on an alarm or include the event in its next scheduled communication.
Features & Benefits
- Pulse inputs
- 4
- Dedicated alarm inputs
- 4
- Data retention
- 120 days of 60-minute data
- Intervals
- 1, 5, 15, 30 or 60 min
- Eliminates installation and maintenance of wireline links
Applications
- Synchronized gas-day readings and interval data collection
Detailed capabilities
SIP-CB Data Logger — product role
SIP-CB combines four pulse-counting channels with a GSM/GPRS modem to send interval readings to supported meter data systems. Pulse channels can alternatively monitor status, alongside four dedicated alarm inputs. The logger can call immediately on an alarm or include the event in its next scheduled communication.
Counting and alarm operation
SIP-CB counts low-frequency pulses during a selected interval, saves the totals and begins a new interval. At scheduled times or on demand it uses GSM to deliver records to a central computer. Any pulse input can instead monitor status, and four additional inputs are dedicated to alarm or status signals.
Recording and remote updates
Four pulse channels provide the published 120-day history at hourly intervals. The logger supports five interval choices, four configurable digital outputs, encrypted IP access and remote firmware or configuration downloads. It supplies synchronized gas-day readings to supported DC2009 and MV-90 xi systems and can initiate an immediate alarm call instead of waiting for the scheduled transfer.
Mechanical & Physical Properties
- Sizes
- 6.5 x 9.5 x 2 in
Electrical Specifications
- Wetting Voltage per Input
- 3.3 V
- Wetting Current per Input
- 100 µA
Environmental Conditions
- Relative Humidity
- 0 to 90% RH (Non-Condensing)
Standards & Certifications
- Protection Class
- IP65
Material Specifications
- Materials
- Polycarbonate
Others
- Operating Temperature Range
- -30 to 55 deg C
| Parameter | Published value / configuration |
|---|---|
| Sizes | 6.5 x 9.5 x 2 in |
| Wetting Voltage per Input | 3.3 V |
| Wetting Current per Input | 100 µA |
| Relative Humidity | 0 to 90% RH (Non-Condensing) |
| Protection Class | IP65 |
| Materials | Polycarbonate |
| Operating Temperature Range | -30 to 55 deg C |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 2001-0195-003S | UA SIP-CB DATALOGGER 4CH | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
SIP-CB Data Logger image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.