Dataloggers & Pressure Recorders
Pulse Accumulator
The Mercury Pulse Accumulator records low-frequency pulses from two independently scaled sources.
The Mercury Pulse Accumulator records low-frequency pulses from two independently scaled sources. Wall or meter mounting supports commercial and industrial automatic meter reading, while selectable communications and call initiation options connect records to collection systems. Each input maintains its own accumulated total, allowing different pulse values or units on the same instrument.
Features & Benefits
- Inputs
- 2 independent pulse channels
- Call initiation
- Host or instrument
- Audit trail
- 41 days of hourly data with four selected items
- Independent scaling accommodates different pulse sources
Applications
- Commercial and industrial smart metering and AMR
Detailed capabilities
Pulse Accumulator — product role
The Mercury Pulse Accumulator records low-frequency pulses from two independently scaled sources. Wall or meter mounting supports commercial and industrial automatic meter reading, while selectable communications and call initiation options connect records to collection systems. Each input maintains its own accumulated total, allowing different pulse values or units on the same instrument.
Independent pulse accumulation
The two input channels operate as separate accumulators, each with its own wetting voltage and pulse-volume value. An additional scaling factor can be applied before counts enter the total, allowing different source units on the same recorder. Both inputs can therefore serve independent measurement streams without imposing a common pulse increment.
Collection, memory and communications
Host-initiated and instrument-initiated calls are supported, including shared-line behavior. The published audit arrangement holds forty-one days of hourly data for four selected items. Wireless options include cellular, satellite and radio arrangements, while power control supports battery modem operation for wall- or meter-mounted commercial and industrial collection.
Memory & Storage
- SIM Card
- 4FF
Environmental Conditions
- Cellular Antenna Type
- Internal LTE with GPS, External LTE (SMA Connector)
- Relative Humidity
- 0 to 100% RH (Non-Condensing)
- Safety Rating
- Class 1 Division 2 Certified (Groups A, B, C, D), Temperature Code T5, CSA C22.2 No. 213:2017, UL 121201:2017
- Battery Life
- 8+ Years with Hourly Reporting
Electrical Specifications
- Cellular Radio Power
- 23 dBm
- Power Supply
- (4) D-Cell Lithium Battery Pack (Field Replaceable), 10 to 30 VDC Input
Communication & Protocols
- Supported Bands
- B1, B2, B3, B4, B5, B8, B12, B13, B14, B17, B20, B25, B26, B28, B66
- Connectivity
- Cat M1 Cellular Modem (LTE CAT M1), Supports 2G/3G Modem-Based Applications
Technical Specifications
- Inputs/Outputs
- (2) Digital Inputs (State, Total Counts, Frequency up to 2 kHz, Volume Total with K Factor); 1 Pulse Output (Future)
I/O Capabilities
- Configuration
- Local Micro-USB Configuration Port
- Integration
- PowerSpring, SCADA, Third-party MDM systems
Applications & Compatibility
- Applications
- CandI Smart Metering/AMI, Automatic Meter Reading (AMR), Meter Data Management (MDM), SCADA Integration
Mechanical & Physical Properties
- Enclosure
- Industrial Polycarbonate, UV Rated, IP64
Others
- Operating Temperature Range
- -40 to +185 deg F; -40 to +85 deg C
| Parameter | Published value / configuration |
|---|---|
| SIM Card | 4FF |
| Cellular Antenna Type | Internal LTE with GPS, External LTE (SMA Connector) |
| Relative Humidity | 0 to 100% RH (Non-Condensing) |
| Safety Rating | Class 1 Division 2 Certified (Groups A, B, C, D), Temperature Code T5, CSA C22.2 No. 213:2017, UL 121201:2017 |
| Battery Life | 8+ Years with Hourly Reporting |
| Cellular Radio Power | 23 dBm |
| Power Supply | (4) D-Cell Lithium Battery Pack (Field Replaceable), 10 to 30 VDC Input |
| Supported Bands | B1, B2, B3, B4, B5, B8, B12, B13, B14, B17, B20, B25, B26, B28, B66 |
| Connectivity | Cat M1 Cellular Modem (LTE CAT M1), Supports 2G/3G Modem-Based Applications |
| Inputs/Outputs | (2) Digital Inputs (State, Total Counts, Frequency up to 2 kHz, Volume Total with K Factor); 1 Pulse Output (Future) |
| Configuration | Local Micro-USB Configuration Port |
| Integration | PowerSpring, SCADA, Third-party MDM systems |
| Applications | CandI Smart Metering/AMI, Automatic Meter Reading (AMR), Meter Data Management (MDM), SCADA Integration |
| Enclosure | Industrial Polycarbonate, UV Rated, IP64 |
| Operating Temperature Range | -40 to +185 deg F; -40 to +85 deg C |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
4 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 206P0 | PULSE TRANSMITTER STANDARD | Request quotation |
| 206P1 | PULSE TRANSMITTER MOD F/ ADDL MNTG CLRNC | Request quotation |
| 206P2 | PULSE TRANSMITTER FOR MIWI350 | Request quotation |
| CPA150-A0-000 | CPA150, 4D CELL PACK,INTERN ANT | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Pulse Accumulator image · Manufacturer ownership retained; republication licence not independently confirmed