Dataloggers & Pressure Recorders
ERX350 Pressure Monitor
ERX350 records gas network pressure and issues alarms at line ends, low-pressure points and district regulator stations.
ERX350 records gas network pressure and issues alarms at line ends, low-pressure points and district regulator stations. Derived from the EC350 platform, it combines a replaceable digital pressure transducer with diagnostic and cellular communication capabilities. Its service-oriented enclosure and shared operating interface help simplify instrument maintenance and field repairs.
Models: ERX350 Pressure Monitor
Features & Benefits
- Measurement
- Digital pressure transducer
- Functions
- Pressure monitoring, recording and alarms
- Helps reduce site visits and maintenance effort
Applications
- Gas distribution and transmission pressure monitoring
Detailed capabilities
ERX350 Pressure Monitor — product role
ERX350 records gas network pressure and issues alarms at line ends, low-pressure points and district regulator stations. Derived from the EC350 platform, it combines a replaceable digital pressure transducer with diagnostic and cellular communication capabilities. Its service-oriented enclosure and shared operating interface help simplify instrument maintenance and field repairs.
Serviceable pressure recording
ERX350 uses a plug-and-play digital pressure transducer and an enclosure arranged for field service. Its EC350-derived interface gives technicians a familiar configuration experience. A robust locking and latching arrangement, expanded memory and diagnostic functions support maintenance, while cellular communication extends access beyond the local recorder.
Pressure-network applications
The instrument monitors line ends, low-pressure locations and district regulators, recording conditions and issuing alarms. The manufacturer associates stable measurement and longer battery service with fewer visits, while accessible components simplify repairs when a visit is required. Its published function is pressure-system observation rather than gas volume correction.
Communication & Protocols
- GPS
- Optional, but typically left inactive to conserve battery
- Network Interface
- APN configurable; SIM card slot; Supports redundant MQTT brokers
- Communication
- LTE-M cellular network; MQTT Sparkplug B protocol for server connection
I/O Capabilities
- Mounting Options
- UMB, Rotary, and Wall-mount
- Configuration
- Cloud-based visualization, trending, and alarming; Local via micro-USB port and MasterLink 150 software
Technical Specifications
- Inputs/Outputs
- Screw terminals for I/O expansion; microSD card slot (future use)
Electrical Specifications
- Power Supply
- Battery life estimate shown in config (typical: 1.7 years at 3.763 mA); Internal lithium battery pack (default)
Environmental Conditions
- Battery Life
- Extended 10-year Lithium Battery Life
Applications & Compatibility
- Applications
- Gas Distribution Network Pressure Monitoring, Custody Transfer, Industrial Measurement
Measurement & Sensor Related (Measurement Capabilities)
- Measurement
- Pressure recording for low pressure points in gas distribution
Processing & Performance Metrics
- Data Backup
- Auto-upload when network reconnects; Internal backup of minimum 200 datapoints
Mechanical & Physical Properties
- Enclosure
- Industrial Polycarbonate, Weather-Resistant
Standards & Certifications
- Approvals
- Class I Div 2 (implied by platform), Designed for Hazardous Locations
Software & Interface
- Firmware
- Version and uptime displayed in system status
Functional & Control Features
- Alarms
- Low and high pressure alarms (configurable thresholds, enable/disable)
| Parameter | Published value / configuration |
|---|---|
| GPS | Optional, but typically left inactive to conserve battery |
| Network Interface | APN configurable; SIM card slot; Supports redundant MQTT brokers |
| Communication | LTE-M cellular network; MQTT Sparkplug B protocol for server connection |
| Mounting Options | UMB, Rotary, and Wall-mount |
| Configuration | Cloud-based visualization, trending, and alarming; Local via micro-USB port and MasterLink 150 software |
| Inputs/Outputs | Screw terminals for I/O expansion; microSD card slot (future use) |
| Power Supply | Battery life estimate shown in config (typical: 1.7 years at 3.763 mA); Internal lithium battery pack (default) |
| Battery Life | Extended 10-year Lithium Battery Life |
| Applications | Gas Distribution Network Pressure Monitoring, Custody Transfer, Industrial Measurement |
| Measurement | Pressure recording for low pressure points in gas distribution |
| Data Backup | Auto-upload when network reconnects; Internal backup of minimum 200 datapoints |
| Enclosure | Industrial Polycarbonate, Weather-Resistant |
| Approvals | Class I Div 2 (implied by platform), Designed for Hazardous Locations |
| Firmware | Version and uptime displayed in system status |
| Alarms | Low and high pressure alarms (configurable thresholds, enable/disable) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
5 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 40-5103-1-KIT | KIT CNI2 PCB WO RADIO OR HDWR | Request quotation |
| 40-6133-KIT-25 | KIT,ASSY CNI2E-H CAPACITOR PLUG 25NO | Request quotation |
| 40-6133-KIT-5 | KIT,ASSY CNI2E-H CAPACITOR PLUG 5NO | Request quotation |
| ERX150 | S150 PRESSURE MONITOR | Request quotation |
| MIO150 | S150 IO MONITORING | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
ERX350 Pressure Monitor · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.