Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Dataloggers & Pressure Recorders

DL230 Datalogger

DL230 records gas meter load profiles and peak demand through four input channels.

DL230 records gas meter load profiles and peak demand through four input channels. Two channels can instead read encoder indexes, and unused consumption inputs can monitor status signals. Its integrated GSM/GPRS modem supports battery operation or an internal supply, with DLMS/COSEM communication and automatic push transfer to data collection systems.

Models: DL230 Datalogger

Features & Benefits

Inputs
4, with 2 supporting encoder indexes
Communications
GSM/GPRS and DLMS/COSEM
  • Combines load recording with simple station monitoring

Applications

  • Commercial and industrial gas metering

Specifications

I/O Capabilities

Inputs
(4) Digital Inputs (intrinsically safe), Max Input Frequency: 10 Hz, (2) Inputs can connect to encoder indexes (Namur, SCR/SCR+)
Control Panel
7-Key Plastic-Coated Keypad
Modem Module
2G (GSM/GPRS), 4G (LTE-M/NB-IoT); Antenna on housing or external
Outputs
(2) Freely Programmable, Sealable Digital Transistor Outputs (Umax = 30 VDC, Imax = 100 mA); Can be used as pulse output (max 4 Hz), status output, or time synchronization output

Electrical Specifications

Communication Module Power
Modem can be powered by up to 2 lithium batteries (3.6 V, 8 Ah); Usually via power supply unit
Power Supply
(1)/(2) Lithium Batteries (3.6 V, 13 Ah)

Environmental Conditions

Ambient Temperature Range
-25 to +60 deg C, Max
Relative Humidity
93% RH, Non-Condensing

Standards & Certifications

Metrological Approvals
PTB approval as peak-load display and registration device for gas and water meters
Protection Class
IP65 (EN 60529)
ATEX Approval
Associated Apparatus for Ex Zone 0/1, Manufacturer’s Declaration for Ex Zone 2
PTB Approval
Type Examination Certificate DE-17-M-PTB-0025 (PTB-A 50.7)

Communication & Protocols

Data Communication
FTP (PUSH), TCPServ (PULL), GSM/CSD (PULL), SMS (PUSH)
Data Protocols
IEC 62056-21, DLMS/COSEM (AES-128 Encryption), FTP, SMS

Material Specifications

Housing Material
Plastic with cable glands

Applications & Compatibility

Applications
Data Logging for Gas Meters, Remote Data Transfer for Billing, System Monitoring

Communication Interfaces

Interfaces
Optical (IEC 62056-21), RS232/RS485 or Ethernet (optional plug-in module)

Dimensions & Weight

Dimensions
175 mm W x 85 mm H x 250 mm L (Including Cable Glands)

Software & Interface

Display
Dot Matrix, 200 x 80 pixels, Backlit
DL230 Datalogger — manufacturer page values
ParameterPublished value / configuration
Inputs(4) Digital Inputs (intrinsically safe), Max Input Frequency: 10 Hz, (2) Inputs can connect to encoder indexes (Namur, SCR/SCR+)
Control Panel7-Key Plastic-Coated Keypad
Modem Module2G (GSM/GPRS), 4G (LTE-M/NB-IoT); Antenna on housing or external
Outputs(2) Freely Programmable, Sealable Digital Transistor Outputs (Umax = 30 VDC, Imax = 100 mA); Can be used as pulse output (max 4 Hz), status output, or time synchronization output
Communication Module PowerModem can be powered by up to 2 lithium batteries (3.6 V, 8 Ah); Usually via power supply unit
Power Supply(1)/(2) Lithium Batteries (3.6 V, 13 Ah)
Ambient Temperature Range-25 to +60 deg C, Max
Relative Humidity93% RH, Non-Condensing
Metrological ApprovalsPTB approval as peak-load display and registration device for gas and water meters
Protection ClassIP65 (EN 60529)
ATEX ApprovalAssociated Apparatus for Ex Zone 0/1, Manufacturer’s Declaration for Ex Zone 2
PTB ApprovalType Examination Certificate DE-17-M-PTB-0025 (PTB-A 50.7)
Data CommunicationFTP (PUSH), TCPServ (PULL), GSM/CSD (PULL), SMS (PUSH)
Data ProtocolsIEC 62056-21, DLMS/COSEM (AES-128 Encryption), FTP, SMS
Housing MaterialPlastic with cable glands
ApplicationsData Logging for Gas Meters, Remote Data Transfer for Billing, System Monitoring
InterfacesOptical (IEC 62056-21), RS232/RS485 or Ethernet (optional plug-in module)
Dimensions175 mm W x 85 mm H x 250 mm L (Including Cable Glands)
DisplayDot Matrix, 200 x 80 pixels, Backlit

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

DL230 DataloggerRequest quotation ›
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/distribution/dataloggers-and-pressure-recorders/dl230-datalogger

Last source check: 2026-11-02

DL230 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry