Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Communication Devices

EA_Water Module 3.0

EA_Water 3.0 carries readings from compatible encoded or digital water-meter registers through EnergyAxis.

EA_Water 3.0 carries readings from compatible encoded or digital water-meter registers through EnergyAxis. Its two-way mesh connection finds a path to the Gatekeeper and synchronizes reading intervals with network time. Installers set meter compatibility and capture account details in the field, with integral, remote and pit forms offered for different installations.

Models: EA_Water Module 3.0

Features & Benefits

Network
EnergyAxis LAN
Remote wiring
Up to 100 ft / 30 m
  • Field-configured compatibility simplifies deployment

Applications

  • Water AMI data collection

Detailed capabilities

EA_Water Module 3.0 — product role

EA_Water 3.0 carries readings from compatible encoded or digital water-meter registers through EnergyAxis. Its two-way mesh connection finds a path to the Gatekeeper and synchronizes reading intervals with network time. Installers set meter compatibility and capture account details in the field, with integral, remote and pit forms offered for different installations.

Manufacturer reference ↗

Meter register pairing and installation

EA_Water supports encoded or digital registers and allows compatibility to be configured in the field with the account information. Factory-integrated, remote wall/pipe and pit installations are offered, with up to thirty meters of wiring for the remote arrangement. The source names Honeywell, Badger, Hersey, Metron Farnier, Neptune and Sensus register suppliers.

Manufacturer reference ↗

Two-way mesh and interval timing

The module selects a first-hop route toward the EnergyAxis Gatekeeper and synchronizes intervals with network time. This produces aligned readings rather than unscheduled individual broadcasts. AES-128 protects communication and firmware-update delivery, and the module returns to its earlier configuration after a verified remote upgrade.

Manufacturer reference ↗

Radio and housing qualifications

The published radio uses unlicensed frequency hopping from902 to928MHz. The listed temperature range is -40 to65°C, with IP67 for remote and IP68 for pit housings. Fixed or hybrid mobile/fixed modes are available, and FCC Part15 and Industry Canada RSS-210 are named in the source.

Manufacturer reference ↗

Specifications

General Overview

Applications
Advanced water metering infrastructure (AMI)
System Integration
Works within EnergyAxis® System
Device Type
Water AMI communication module (network endpoint)
Architecture
IP-based, scalable AMI network (EnergyAxis)

Compatibility

Supported Vendors
AMCO (Honeywell), Badger, Hersey, Metron Farnier, Neptune, Sensus
Meter Compatibility
Supports encoded and digital water meter registers

Communication

RF Technology
FHSS (Frequency Hopping Spread Spectrum)
Operation Modes
Fixed network/Hybrid (mobile + fixed)
Network Type
EnergyAxis mesh LAN (EA_LAN)
Network Optimization
Automatic path selection to Gatekeeper
Communication Modes
Two-way communication

Physical

Protection Class
Remote: IP67, Pit: IP68

Operating Conditions

Operating Temperature Range
-40 to +65 deg C

Deployment & Installation

Mounting Options
Pit-mounted or remote-mounted

Electrical Characteristics

Frequency Range
902 to 928 MHz

Security

Data Encryption
AES‑128 bit encryption

Safety & Compliance

Approvals
NIST, NEMA, FIPS-based security architecture (via EnergyAxis)
EA_Water Module 3.0 — manufacturer page values
ParameterPublished value / configuration
ApplicationsAdvanced water metering infrastructure (AMI)
System IntegrationWorks within EnergyAxis® System
Device TypeWater AMI communication module (network endpoint)
ArchitectureIP-based, scalable AMI network (EnergyAxis)
Supported VendorsAMCO (Honeywell), Badger, Hersey, Metron Farnier, Neptune, Sensus
Meter CompatibilitySupports encoded and digital water meter registers
RF TechnologyFHSS (Frequency Hopping Spread Spectrum)
Operation ModesFixed network/Hybrid (mobile + fixed)
Network TypeEnergyAxis mesh LAN (EA_LAN)
Network OptimizationAutomatic path selection to Gatekeeper
Communication ModesTwo-way communication
Protection ClassRemote: IP67, Pit: IP68
Operating Temperature Range-40 to +65 deg C
Mounting OptionsPit-mounted or remote-mounted
Frequency Range902 to 928 MHz
Data EncryptionAES‑128 bit encryption
ApprovalsNIST, NEMA, FIPS-based security architecture (via EnergyAxis)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

EA_Water Module 3.0Request quotation ›
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/electricity/communications/communication-devices/ea-water-module-3-0

Last source check: 2026-11-02

EA_Water Module 3.0 image · Manufacturer ownership retained; republication licence not independently confirmed