Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Communication Devices

EA_Gas Module 3.0

EA_Gas 3.0 connects gas meters to the EnergyAxis mesh network with two-way communication and synchronized interval readings.

EA_Gas 3.0 connects gas meters to the EnergyAxis mesh network with two-way communication and synchronized interval readings. Compatibility is configured during installation, while account information is captured at the same time. Integral, remote and pit installation choices support different sites, and the module automatically finds its network path toward the Gatekeeper.

Models: EA_Gas Module 3.0

Features & Benefits

Network
EnergyAxis LAN
Remote wiring
Up to 100 ft / 30 m
  • Configuration during installation simplifies inventory and deployment

Applications

  • Gas AMI data collection

Detailed capabilities

EA_Gas Module 3.0 — product role

EA_Gas 3.0 connects gas meters to the EnergyAxis mesh network with two-way communication and synchronized interval readings. Compatibility is configured during installation, while account information is captured at the same time. Integral, remote and pit installation choices support different sites, and the module automatically finds its network path toward the Gatekeeper.

Manufacturer reference ↗

Field configuration and mounting

EA_Gas compatibility is set during installation along with account details. Integral assemblies can arrive preinstalled on a meter, while remote wall or pipe mounts allow up to one hundred feet of wiring; pit forms are also listed. This separates endpoint inventory from a preassigned address or one meter brand and supports staged deployment.

Manufacturer reference ↗

Synchronized mesh reading and secure updates

The two-way EnergyAxis connection finds a route toward the Gatekeeper and uses network time for aligned meter intervals. AES-128 protects data and remote firmware images. After a verified over-the-air update the module resumes its previous programmed operation, linking maintenance of the communication endpoint with continued collection.

Manufacturer reference ↗

Housing, radio and compatibility qualification

The source lists 902–928MHz frequency-hopping operation, -40 to65°C, IP67 remote housing and IP68 pit housing, with fixed or hybrid mobile/fixed modes. Its register-supplier compatibility list appears inconsistent with the gas product context. Those names are not converted into confirmed gas-meter compatibility; the actual register pairing needs product-specific confirmation.

Manufacturer reference ↗

Specifications

General Overview

Applications
Commercial diaphragm gas meters, AMI network management
System Integration
EnergyAxis® System (EA_LAN network element)
Device Type
Gas AMI/AMR communication module (network endpoint)
Architecture
Open architecture supporting multi-utility integration

Communication

Time Synchronization
Interval data synchronized with real-time via network signals
RF Technology
FHSS (Frequency Hopping Spread Spectrum)
Operation Modes
AMI (Fixed), AMR (Mobile), or Hybrid
Network Type
EnergyAxis mesh LAN (EA_LAN)
Communication Modes
Two-way communication

Compatibility

Supported Models
Honeywell AL800–5000, Sensus 750–1000 and 2–5, Itron 675–1000
Meter Compatibility
Supports major commercial diaphragm meters

Operating Conditions

Operating Temperature Range
-40 to +65 deg C

Deployment & Installation

Mounting Options
Factory-installed or retrofit on existing meters

Environmental

Humidity
5% to 95% non-condensing

Electrical Characteristics

Frequency Range
902 to 928 MHz

Security

Data Encryption
AES‑128 bit encryption

Power

Battery Lifetime
>20 years under normal conditions

Safety & Compliance

Approvals
FCC Part 15, Industry Canada RSS-210
EA_Gas Module 3.0 — manufacturer page values
ParameterPublished value / configuration
ApplicationsCommercial diaphragm gas meters, AMI network management
System IntegrationEnergyAxis® System (EA_LAN network element)
Device TypeGas AMI/AMR communication module (network endpoint)
ArchitectureOpen architecture supporting multi-utility integration
Time SynchronizationInterval data synchronized with real-time via network signals
RF TechnologyFHSS (Frequency Hopping Spread Spectrum)
Operation ModesAMI (Fixed), AMR (Mobile), or Hybrid
Network TypeEnergyAxis mesh LAN (EA_LAN)
Communication ModesTwo-way communication
Supported ModelsHoneywell AL800–5000, Sensus 750–1000 and 2–5, Itron 675–1000
Meter CompatibilitySupports major commercial diaphragm meters
Operating Temperature Range-40 to +65 deg C
Mounting OptionsFactory-installed or retrofit on existing meters
Humidity5% to 95% non-condensing
Frequency Range902 to 928 MHz
Data EncryptionAES‑128 bit encryption
Battery Lifetime>20 years under normal conditions
ApprovalsFCC Part 15, Industry Canada RSS-210

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

EA_Gas Module 3.0Request quotation ›

Published part numbers

5 parts

Part NumberDescriptionEnquiry
3A35310H01VANDAL PLUG/RED ( same as 52548P010)Request quotation
3A35389H01ESD SUPPRESSORRequest quotation
EAHANDHELDCT-60 AMI HANDHELD START UP BUNDLERequest quotation
EG100002000Mounting Kit, Remote, Wall Mount, No CBLRequest quotation
EG210001000EA GAS 2.0 INTEGRAL MOUNTING KIT- AMCORequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/electricity/communications/communication-devices/ea-gas-module-3-0

Last source check: 2026-11-02

EA_Gas Module 3.0 image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry