Commercial & Industrial Meters
A3 ALPHA Meter
A3 ALPHA with W-WIC retrieves billing information from meter registers and forwards it over a cellular network to the utility head end.
A3 ALPHA with W-WIC retrieves billing information from meter registers and forwards it over a cellular network to the utility head end. The configuration supports energy, demand, reactive and apparent measurements, time-of-use records, bidirectional energy and load profiles. Its published capability therefore combines the meter with the specifically described wireless communication arrangement.
Models: A3 ALPHA Meter
Features & Benefits
- Communications
- W-WIC cellular link
- Data
- Energy, demand, power factor, instrumentation and load profile
- Transfers register data directly to the utility head end
Applications
- Electricity billing and interval measurement
Measurement & Metrology
- Apparent Energy
- kVA, apparent demand
- Reactive Energy
- kVARh and reactive demand
Operating Conditions
- Voltage Range
- 96 to 528 V operating range
- Temperature Range
- Operating:-40 to +55 deg C
General Overview
- Variant
- A3T (timekeeping), A3K (apparent), A3R (reactive), A3Q (Q-hour)
- Meter Types
- A3 ALPHA smart meter with integrated wireless WAN interface card (W‑WIC)
- Applications
- Utility smart grid, large-scale device communication (AMI environment)
Prepayment (STS)
- Software
- Metercat™ for configuration and testing
- Security
- AES‑128 bit encryption
Interfaces
- Outputs
- Relay: Supports any phase and 2 or 6 KYZ relays
Environmental
- Humidity
- 0 to 100%
Measurement & Data
- Energy Registers
- kWh energy consumption
- Demand Registers
- Maximum demand (kW, kVAR)
Control & Interface
- Display Type
- Can display cellular signal strength on LCD
Communication
- Communication Type
- Direct WAN-connected meter (no intermediary devices required)
- Communication Protocol
- ANSI C12.22 (IP-based)
- Cellular Technology
- LTE (4G) Cat M1
Safety & Compliance
- Approvals
- ANSI C12.1, C12.10, C12.18, C12.19, C12.20, C12.22
| Parameter | Published value / configuration |
|---|---|
| Apparent Energy | kVA, apparent demand |
| Reactive Energy | kVARh and reactive demand |
| Voltage Range | 96 to 528 V operating range |
| Temperature Range | Operating:-40 to +55 deg C |
| Variant | A3T (timekeeping), A3K (apparent), A3R (reactive), A3Q (Q-hour) |
| Meter Types | A3 ALPHA smart meter with integrated wireless WAN interface card (W‑WIC) |
| Applications | Utility smart grid, large-scale device communication (AMI environment) |
| Software | Metercat™ for configuration and testing |
| Security | AES‑128 bit encryption |
| Outputs | Relay: Supports any phase and 2 or 6 KYZ relays |
| Humidity | 0 to 100% |
| Energy Registers | kWh energy consumption |
| Demand Registers | Maximum demand (kW, kVAR) |
| Display Type | Can display cellular signal strength on LCD |
| Communication Type | Direct WAN-connected meter (no intermediary devices required) |
| Communication Protocol | ANSI C12.22 (IP-based) |
| Cellular Technology | LTE (4G) Cat M1 |
| Approvals | ANSI C12.1, C12.10, C12.18, C12.19, C12.20, C12.22 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
A3 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.