PressureTrol® Pressure monitoring on/off controllers L404F, T, V

L404 PressureTrol provides automatic-reset pressure switching with adjustable differential.

L404 PressureTrol provides automatic-reset pressure switching with adjustable differential. L404F addresses the stated pressure-system media, while T and V serve oil burners with different high- and low-pressure actions. A clear cover exposes the settings, and the page publishes distinct system-pressure limits for the general and oil-burner groups.

Features & Benefits

Maximum Diaphragm Pressure
Up to 350 psi (2410 kPa)
Ambient Temperature Limits
Max 150 deg F (66 deg C)
Operating Pressure Range
10 to 150 psi|2 to 15 psi|20 to 300 psi (model dependent)|5 to 50 psi
Maximum System Pressure
L404F: Up to 300 psi (2070 kPa)|L404T/L404V: Up to 150 psi (1035 kPa)
Maintenance Interval
Occasional scaleplate adjustment; annual checkout recommended
Differential Range
Adjustable; varies by model (e.g., 2 to 6 psi, 6 to 14 psi, 20 to 50 psi)
Electrical Rating
120 VAC: 8.0 A (Full Load), 48.0 A (Locked Rotor)|240 VAC: 5.1 A (Full Load), 30.6 A (Locked Rotor)
Control Functions
Operating control with automatic reset
Conduit Entries
Knockouts for 1/2 in conduit
Mounting Types
1/4-18 NPT pipe fitting or surface mount via case knockouts
Switch Action
Snap switch: breaks R-B, makes R-W on pressure rise
Switch Type
MicroSwitch® snap‑acting switch
Reset Type
Automatic reset
Approvals
UL Listed (MP466), CSA Approved (LR1620), WEEE Directive 2012/19/EU - Waste Electrical and Electronic Equipment Directive
Material
Rigid case with clear plastic cover
  • Automatic reset and adjustable differential support pressure cycling.

Applications

  • Pressure-system operating/limit control
  • Oil-burner pressure supervision with T/V variants

Detailed capabilities

Different switch actions for process and oil duty

L404F provides operating control and automatic pressure limiting for the stated process media. L404T opens on excessive oil pressure, while L404V makes its circuit as oil pressure rises from a low-pressure condition. All reset automatically and have adjustable differential. The higher general-system pressure capability must not be assigned to the lower-pressure oil versions.

Manufacturer reference ↗

Features and benefits

  • Automatic reset and adjustable differential support pressure cycling.

Manufacturer reference ↗

Published application context

  • Pressure-system operating/limit control
  • Oil-burner pressure supervision with T/V variants

Manufacturer reference ↗

Specifications

Overview

Models
L404F, L404T, L404V

Pressure Specifications

Maximum Diaphragm Pressure
Up to 350 psi (2410 kPa)
Operating Pressure Range
10 to 150 psi; 2 to 15 psi; 20 to 300 psi (model dependent); 5 to 50 psi
Maximum System Pressure
L404F: Up to 300 psi (2070 kPa); L404T/L404V: Up to 150 psi (1035 kPa)

Environmental Conditions

Ambient Temperature Limits
Max 150 deg F (66 deg C)

Electrical Specifications

Maintenance Interval
Occasional scaleplate adjustment; annual checkout recommended

Measurement, Media & Physical Properties

Differential Range
Adjustable; varies by model (e.g., 2 to 6 psi, 6 to 14 psi, 20 to 50 psi)

Electrical & Signal Specifications

Electrical Rating
120 VAC: 8.0 A (Full Load), 48.0 A (Locked Rotor); 240 VAC: 5.1 A (Full Load), 30.6 A (Locked Rotor)

Control, Logic & Functional Behavior

Control Functions
Operating control with automatic reset

Mechanical Design, Layout & Construction Options

Conduit Entries
Knockouts for 1/2 in conduit

Installation & Mounting Specifications

Mounting Types
1/4-18 NPT pipe fitting or surface mount via case knockouts

Actuation, Control & Motion Characteristics

Switch Action
Snap switch: breaks R-B, makes R-W on pressure rise
Switch Type
MicroSwitch® snap‑acting switch

Applications & Compatibility

Applications
L404F: Steam, air, non‑combustible gases, non‑corrosive fluids; L404T: High oil pressure limit (breaks circuit on pressure rise); L404V: Low oil pressure limit (makes circuit on pressure rise)

Safety, Protection & Reliability

Reset Type
Automatic reset

Standards & Certifications

Approvals
UL Listed (MP466), CSA Approved (LR1620), WEEE Directive 2012/19/EU - Waste Electrical and Electronic Equipment Directive

Material Specifications

Material
Rigid case with clear plastic cover
PressureTrol® Pressure monitoring on/off controllers L404F, T, V — manufacturer page values
ParameterPublished value / configuration
ModelsL404F, L404T, L404V
Maximum Diaphragm PressureUp to 350 psi (2410 kPa)
Operating Pressure Range10 to 150 psi; 2 to 15 psi; 20 to 300 psi (model dependent); 5 to 50 psi
Maximum System PressureL404F: Up to 300 psi (2070 kPa); L404T/L404V: Up to 150 psi (1035 kPa)
Ambient Temperature LimitsMax 150 deg F (66 deg C)
Maintenance IntervalOccasional scaleplate adjustment; annual checkout recommended
Differential RangeAdjustable; varies by model (e.g., 2 to 6 psi, 6 to 14 psi, 20 to 50 psi)
Electrical Rating120 VAC: 8.0 A (Full Load), 48.0 A (Locked Rotor); 240 VAC: 5.1 A (Full Load), 30.6 A (Locked Rotor)
Control FunctionsOperating control with automatic reset
Conduit EntriesKnockouts for 1/2 in conduit
Mounting Types1/4-18 NPT pipe fitting or surface mount via case knockouts
Switch ActionSnap switch: breaks R-B, makes R-W on pressure rise
Switch TypeMicroSwitch® snap‑acting switch
ApplicationsL404F: Steam, air, non‑combustible gases, non‑corrosive fluids; L404T: High oil pressure limit (breaks circuit on pressure rise); L404V: Low oil pressure limit (makes circuit on pressure rise)
Reset TypeAutomatic reset
ApprovalsUL Listed (MP466), CSA Approved (LR1620), WEEE Directive 2012/19/EU - Waste Electrical and Electronic Equipment Directive
MaterialRigid case with clear plastic cover

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
4074BWJ/ULIMIT STOP ASSEMBLY FOR L404/L604. INCLRequest quotation
EC16072SW,PRESS,AIR/GAS,LO,MAN RST,1 26 IN.WC,NRequest quotation
EC16118SW,PRESS,AIR/GAS,LO,MAN RST,0.5 5 PSI,NERequest quotation
L404F1060/UPRESSURETROLRequest quotation
L404F1078/UPRESSURETROLRequest quotation
L404F1094/UPRESSURE SWITCHRequest quotation
L404F1102/U10-150PSI PRESSURETOLRequest quotation
L404F1219/UPRESSURETROL 2-15PSIRequest quotation
L404F1227/UPRESSURETROLRequest quotation
L404F1235/UPRESSURETROL 20-300PSIRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/pressure-switches-and-gauges/pressuretrol-pressure-monitoring-on-off-controllers-l404f-t-v

Last source check: 2026-11-02

PressureTrol® Pressure monitoring on/off controllers · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry