L4079 PressureTrol limits open circuits when pressure exceeds the setting and require manual reset.

L4079 PressureTrol limits open circuits when pressure exceeds the setting and require manual reset. A/B models cover the stated noncorrosive media, while W adds seals for oil service. Switch count varies by model, and the trip-free mechanism prevents the reset lever from defeating the pressure limit.

Features & Benefits

Maximum Diaphragm Pressure
Up to 350 psi (2410 kPa) depending on model
Ambient Temperature Limits
Max 150 deg F (66 deg C)
Maintenance Interval
Manual reset and annual function check recommended
Media Compatibility
L4079A, L4079B: Steam, Air, Non‑Combustible Gases, Non‑Corrosive Fluids|L4079W: Oil Burner Systems
Differential Range
3 to 60 psi (20.7 to 413.7 kPa) depending on model
Electrical Rating
120 VAC: 9.8 A (Full Load), 58.8 A (Locked Rotor)|240 VAC: 4.9 A (Full Load), 29.4 A (Locked Rotor)
Control Functions
Safety limit (manual reset)
Adjustment Method
External screw; scale in psi and kPa
Primary Function
Breaks electrical circuit on pressure rise
Pressure Range
10 to 150 psi (70 to 1035 kPa)|2 to 15 psi (15 to 100 kPa)|20 to 300 psi (140 to 2070 kPa)|5 to 50 psi (35 to 350 kPa)
Mounting Types
1/4-18 NPT pipe fitting|Boiler, wall, or remote mounting
Configurations
L4079A: Two ganged SPST switches (breaks two circuits)|L4079B: One SPST switch (breaks one circuit)|L4079W: One SPST switch with oil‑resistant seals
Switch Action
Opens circuit(s) on pressure rise
Product Type
High‑pressure limit control
Switch Type
MICRO SWITCH® snap‑acting
Reset Type
Manual reset (trip‑free)
Approvals
UL Listed (MP466), CSA Approved (LR95329), WEEE Directive 2012/19/EU compliant
  • The trip-free reset prevents defeating the limit by holding the lever.

Applications

  • High-pressure limiting
  • Oil-burner limiting with L4079W

Detailed capabilities

Trip-free manual reset and model-specific media

L4079A opens two circuits together, B opens one and W adds seals for oil service. Snap switches can be seen through the cover. A rising-pressure event opens automatically, but restoring service requires manual reset; holding or jamming the lever cannot defeat the limit. The stated tolerance of moderate vibration and lack of leveling requirement do not change the model-specific fluid compatibility.

Manufacturer reference ↗

Features and benefits

  • The trip-free reset prevents defeating the limit by holding the lever.

Manufacturer reference ↗

Published application context

  • High-pressure limiting
  • Oil-burner limiting with L4079W

Manufacturer reference ↗

Specifications

Overview

Models
L4079A, L4079B, L4079W
Product Type
High‑pressure limit control

Pressure Specifications

Maximum Diaphragm Pressure
Up to 350 psi (2410 kPa) depending on model
Pressure Range
10 to 150 psi (70 to 1035 kPa); 2 to 15 psi (15 to 100 kPa); 20 to 300 psi (140 to 2070 kPa); 5 to 50 psi (35 to 350 kPa)

Environmental Conditions

Ambient Temperature Limits
Max 150 deg F (66 deg C)

Electrical Specifications

Maintenance Interval
Manual reset and annual function check recommended

Applications & Compatibility

Media Compatibility
L4079A, L4079B: Steam, Air, Non‑Combustible Gases, Non‑Corrosive Fluids; L4079W: Oil Burner Systems

Measurement, Media & Physical Properties

Differential Range
3 to 60 psi (20.7 to 413.7 kPa) depending on model

Electrical & Signal Specifications

Electrical Rating
120 VAC: 9.8 A (Full Load), 58.8 A (Locked Rotor); 240 VAC: 4.9 A (Full Load), 29.4 A (Locked Rotor)

Control, Logic & Functional Behavior

Control Functions
Safety limit (manual reset)

Mechanical Design & Adjustment Characteristics

Adjustment Method
External screw; scale in psi and kPa

Product Overview & Classification

Primary Function
Breaks electrical circuit on pressure rise

Installation & Mounting Specifications

Mounting Types
1/4-18 NPT pipe fitting; Boiler, wall, or remote mounting

Software, Configuration & Cyber

Configurations
L4079A: Two ganged SPST switches (breaks two circuits); L4079B: One SPST switch (breaks one circuit); L4079W: One SPST switch with oil‑resistant seals

Actuation, Control & Motion Characteristics

Switch Action
Opens circuit(s) on pressure rise
Switch Type
MICRO SWITCH® snap‑acting

Safety, Protection & Reliability

Reset Type
Manual reset (trip‑free)

Standards & Certifications

Approvals
UL Listed (MP466), CSA Approved (LR95329), WEEE Directive 2012/19/EU compliant
Pressuretrol® Limit controllers L4079A, B, W, L604N — manufacturer page values
ParameterPublished value / configuration
ModelsL4079A, L4079B, L4079W
Product TypeHigh‑pressure limit control
Maximum Diaphragm PressureUp to 350 psi (2410 kPa) depending on model
Pressure Range10 to 150 psi (70 to 1035 kPa); 2 to 15 psi (15 to 100 kPa); 20 to 300 psi (140 to 2070 kPa); 5 to 50 psi (35 to 350 kPa)
Ambient Temperature LimitsMax 150 deg F (66 deg C)
Maintenance IntervalManual reset and annual function check recommended
Media CompatibilityL4079A, L4079B: Steam, Air, Non‑Combustible Gases, Non‑Corrosive Fluids; L4079W: Oil Burner Systems
Differential Range3 to 60 psi (20.7 to 413.7 kPa) depending on model
Electrical Rating120 VAC: 9.8 A (Full Load), 58.8 A (Locked Rotor); 240 VAC: 4.9 A (Full Load), 29.4 A (Locked Rotor)
Control FunctionsSafety limit (manual reset)
Adjustment MethodExternal screw; scale in psi and kPa
Primary FunctionBreaks electrical circuit on pressure rise
Mounting Types1/4-18 NPT pipe fitting; Boiler, wall, or remote mounting
ConfigurationsL4079A: Two ganged SPST switches (breaks two circuits); L4079B: One SPST switch (breaks one circuit); L4079W: One SPST switch with oil‑resistant seals
Switch ActionOpens circuit(s) on pressure rise
Switch TypeMICRO SWITCH® snap‑acting
Reset TypeManual reset (trip‑free)
ApprovalsUL Listed (MP466), CSA Approved (LR95329), WEEE Directive 2012/19/EU compliant

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
L4079A1035/UPRESSURETROLRequest quotation
L4079A1050/UPRESSURETROLRequest quotation
L4079B1033/UPRESSURETROLRequest quotation
L4079B1041/UPRESSURETROLRequest quotation
L4079B1058/U5-50 PSI OPERATING RANGE. MAX DIAPHRAGMRequest quotation
L4079B1066/UPRESSURETROL LIMIT CONTROLLERRequest quotation
L4079B1074/UPRESSURETROLRequest quotation
L4079B1082/UPRESSURETROLRequest quotation
L4079W1000/UPRESSURETROLRequest quotation
L604N1009/URANGE 10-150 PSI,.7-10.6 KG/CM2,FIXEDRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/pressure-switches-and-gauges/pressuretrol-limit-controllers-l4079a-b-w-l604n

Last source check: 2026-11-02

Pressuretrol® Limit controllers · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry