Blowers & Boosters
TBA60 Turbo Blower Air Direct Drive 60Hz
TBA60 direct-drive blowers cover six pressure groups and 63 sizes for constant-pressure air supply.
TBA60 direct-drive blowers cover six pressure groups and 63 sizes for constant-pressure air supply. A molded scroll, turbine impeller and balanced rotor support efficient operation with reduced vibration. The assembly can rotate to multiple discharge positions, and supporting accessories adapt the blower to piping and operating requirements.
Features & Benefits
- Impeller Locking Mechanism
- 3 setscrews positioned 120 deg apart, torque to 400 in-lb (45 N·m)
- Impeller Balance Standard
- ISO 1940-2, Quality Grade G6.3
- Motor Compatibility
- 60 Hz 3600 rpm standard‑shaft T‑frame motor|Blowers built for CW or CCW rotation (impeller rotates one way per unit)|ODP or TEFC
- Frequency Tolerance
- ±5% of nameplate value
- Discharge Positions
- Casing/discharge rotates to 7 positions; rotation by removing eight bolts.
- Ambient Temperature
- 104 deg F (40 deg C) for Class B insulation
- Voltage Tolerance
- ±10% of nameplate value
- Mounting Options
- Floor or elevated structure with vibration isolation pads
- Housing Material
- Fiberglass casing with molded scroll design
- Pressure Range
- 12 to 36 osig (52 to 155 mbar)
- Impeller Type
- Riveted heavy‑gauge aluminum turbine‑bladed impeller
- Blower Design
- Molded scroll casing with turbine impeller
- Drive Type
- Direct Drive (60 Hz motors)
- Approvals
- ISO 1940-2 (impeller balance); NFPA compliance recommended for safety
- Efficient impeller design reduces required motor power.
- Multiple outlet orientations simplify piping alignment.
Applications
- Constant-pressure air supply
Mechanical Design & Adjustment Characteristics
- Impeller Locking Mechanism
- 3 setscrews positioned 120 deg apart, torque to 400 in-lb (45 N·m)
- Impeller Balance Standard
- ISO 1940-2, Quality Grade G6.3
- Impeller Type
- Riveted heavy‑gauge aluminum turbine‑bladed impeller
- Drive Type
- Direct Drive (60 Hz motors)
Applications & Compatibility
- Motor Compatibility
- 60 Hz 3600 rpm standard‑shaft T‑frame motor; Blowers built for CW or CCW rotation (impeller rotates one way per unit); ODP or TEFC
- Applications
- Combustion air supply and other applications requiring constant low‑pressure air; Supply low‑pressure air at constant pressure
Electrical Specifications
- Frequency Tolerance
- ±5% of nameplate value
- Voltage Tolerance
- ±10% of nameplate value
Actuation, Valve & Motion Control Specifications
- Discharge Positions
- Casing/discharge rotates to 7 positions; rotation by removing eight bolts.
Environmental Conditions
- Ambient Temperature
- 104 deg F (40 deg C) for Class B insulation
Installation & Mounting Specifications
- Mounting Options
- Floor or elevated structure with vibration isolation pads
Material Specifications
- Housing Material
- Fiberglass casing with molded scroll design
Pressure Specifications
- Pressure Range
- 12 to 36 osig (52 to 155 mbar)
Combustion Air, Blower & Emissions Specifications
- Blower Design
- Molded scroll casing with turbine impeller
Standards & Certifications
- Approvals
- ISO 1940-2 (impeller balance); NFPA compliance recommended for safety
| Parameter | Published value / configuration |
|---|---|
| Impeller Locking Mechanism | 3 setscrews positioned 120 deg apart, torque to 400 in-lb (45 N·m) |
| Impeller Balance Standard | ISO 1940-2, Quality Grade G6.3 |
| Impeller Type | Riveted heavy‑gauge aluminum turbine‑bladed impeller |
| Drive Type | Direct Drive (60 Hz motors) |
| Motor Compatibility | 60 Hz 3600 rpm standard‑shaft T‑frame motor; Blowers built for CW or CCW rotation (impeller rotates one way per unit); ODP or TEFC |
| Applications | Combustion air supply and other applications requiring constant low‑pressure air; Supply low‑pressure air at constant pressure |
| Frequency Tolerance | ±5% of nameplate value |
| Voltage Tolerance | ±10% of nameplate value |
| Discharge Positions | Casing/discharge rotates to 7 positions; rotation by removing eight bolts. |
| Ambient Temperature | 104 deg F (40 deg C) for Class B insulation |
| Mounting Options | Floor or elevated structure with vibration isolation pads |
| Housing Material | Fiberglass casing with molded scroll design |
| Pressure Range | 12 to 36 osig (52 to 155 mbar) |
| Blower Design | Molded scroll casing with turbine impeller |
| Approvals | ISO 1940-2 (impeller balance); NFPA compliance recommended for safety |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 101028462 | KIT,LIT,TURBO BLWR AIR,BELT DRV | Request quotation |
| 101028463 | KIT,LIT,TURBO BLWR AIR,DRCT DRV,50 HZ ME | Request quotation |
| 101028464 | KIT,LIT,TURBO BLWR AIR,DRCT DRV,60 HZ ME | Request quotation |
| 50153804-002 | TBA0024-1TIFUTIFDXX01 | Request quotation |
| HK15318 | NUT,SPLINE BLOWER CASING #42ND 20-064 ES | Request quotation |
| HK18578X400R0148 | BLWR,TBA12 10 T 17 CCW L/MTR | Request quotation |
| HK18608 | IMPLR ASSY,TBA12 CW | Request quotation |
| HK18608R0950 | IMPLR ASSY,TBG12 CW W/POLISHED HUB | Request quotation |
| HK18609 | IMPLR ASSY,TBA/TBAB CW | Request quotation |
| HK18610 | IMPLR ASSY,TBA12 7.5 CW | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Turbo Blower Air · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.