Blowers & Boosters
Hermetic Booster
Eclipse hermetic boosters raise the pressure of suitable gases or air/gas mixtures using a motor and rotor sealed inside a steel housing.
Eclipse hermetic boosters raise the pressure of suitable gases or air/gas mixtures using a motor and rotor sealed inside a steel housing. Removing the external shaft seal avoids that leakage and wear point. The rotor can be serviced without disturbing piping; listing and material compatibility remain qualified by the handled gas.
Features & Benefits
- Operating Gas Temperature
- 95 deg F (35 deg C)
- Environmental Requirement
- Ventilation, avoid sunlight/radiant heat
- Outlet Connection
- NPT for smaller units; ANSI 125/150 flanges for larger units
- Motor Power Range
- 0.5 to 20 HP (model‑dependent)
- Gas Compatibility
- BS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases|DG - Digester gas, bio‑gas, landfill gas, sour gas
- Product Variants
- BS (Standard series), DG (Digester Gas series)
- Product Category
- Gas Pressure Booster/Blower
- Outlet Positions
- 4 outlet positions, rotation CW/CCW|Standard = Position #1 CCW
- Maximum Pressure
- 5 psig (344 mbar) for inlet/outlet/test pressure
- Inlet Connection
- NPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges
- Housing Material
- Steel Housing with Powder‑Coated Finish
- Turndown Ratio
- HB‑LC‑3316‑3/4 supports up to 50:1 turndown
- Product Series
- HB (Standard and Digester Gas variants)
- Design Type
- Hermetically sealed booster with internal rotor and motor
- Motor Type
- Explosion‑proof motor, Class I Group D, fan‑cooled
- Frequency
- 60 Hz (other options by factory request)
- Approvals
- UL Listed (MH10098), Massachusetts Board approval
- The hermetic motor arrangement removes shaft-seal leakage and wear.
- The rotor can be removed without disturbing gas piping.
Applications
- Pressure boosting of gases or air/gas mixtures compatible with aluminum and steel
Detailed capabilities
Why the motor is inside the sealed housing
The hermetic design encloses motor and rotor, removing a shaft penetration and its wear/leakage path. Sealed electrical connections and the stated junction/motor construction support the package. Gas compatibility remains limited by aluminum/steel materials and the named listing conditions. Outlet pressure is incoming pressure plus the booster's added rise, so added pressure alone is not the final line pressure.
Features and benefits
- The hermetic motor arrangement removes shaft-seal leakage and wear.
- The rotor can be removed without disturbing gas piping.
Published application context
- Pressure boosting of gases or air/gas mixtures compatible with aluminum and steel
Operating/Process Temperature Ranges
- Operating Gas Temperature
- 95 deg F (35 deg C)
Environmental Conditions
- Environmental Requirement
- Ventilation, avoid sunlight/radiant heat
Connections & Interfaces
- Outlet Connection
- NPT for smaller units; ANSI 125/150 flanges for larger units
- Inlet Connection
- NPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges
Electrical Specifications
- Motor Power Range
- 0.5 to 20 HP (model‑dependent)
- Frequency
- 60 Hz (other options by factory request)
Applications & Compatibility
- Gas Compatibility
- BS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases; DG - Digester gas, bio‑gas, landfill gas, sour gas
- Applications
- Combustion systems requiring added gas pressure or flow stability; Increase gas pressure and flow for combustion systems
Product Overview & Classification
- Product Variants
- BS (Standard series), DG (Digester Gas series)
- Product Series
- HB (Standard and Digester Gas variants)
Overview
- Product Category
- Gas Pressure Booster/Blower
- Design Type
- Hermetically sealed booster with internal rotor and motor
Actuation, Valve & Motion Control Specifications
- Outlet Positions
- 4 outlet positions, rotation CW/CCW; Standard = Position #1 CCW
Pressure Specifications
- Maximum Pressure
- 5 psig (344 mbar) for inlet/outlet/test pressure
Material Specifications
- Housing Material
- Steel Housing with Powder‑Coated Finish
Performance, Flow & Capacity
- Turndown Ratio
- HB‑LC‑3316‑3/4 supports up to 50:1 turndown
Motor Specifications
- Motor Type
- Explosion‑proof motor, Class I Group D, fan‑cooled
Standards & Certifications
- Approvals
- UL Listed (MH10098), Massachusetts Board approval
| Parameter | Published value / configuration |
|---|---|
| Operating Gas Temperature | 95 deg F (35 deg C) |
| Environmental Requirement | Ventilation, avoid sunlight/radiant heat |
| Outlet Connection | NPT for smaller units; ANSI 125/150 flanges for larger units |
| Inlet Connection | NPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges |
| Motor Power Range | 0.5 to 20 HP (model‑dependent) |
| Frequency | 60 Hz (other options by factory request) |
| Gas Compatibility | BS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases; DG - Digester gas, bio‑gas, landfill gas, sour gas |
| Applications | Combustion systems requiring added gas pressure or flow stability; Increase gas pressure and flow for combustion systems |
| Product Variants | BS (Standard series), DG (Digester Gas series) |
| Product Series | HB (Standard and Digester Gas variants) |
| Product Category | Gas Pressure Booster/Blower |
| Design Type | Hermetically sealed booster with internal rotor and motor |
| Outlet Positions | 4 outlet positions, rotation CW/CCW; Standard = Position #1 CCW |
| Maximum Pressure | 5 psig (344 mbar) for inlet/outlet/test pressure |
| Housing Material | Steel Housing with Powder‑Coated Finish |
| Turndown Ratio | HB‑LC‑3316‑3/4 supports up to 50:1 turndown |
| Motor Type | Explosion‑proof motor, Class I Group D, fan‑cooled |
| Approvals | UL Listed (MH10098), Massachusetts Board approval |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10005662 | BSTR,15 2 " W.C.,1500 SCFH,0.25HP/115VAC | Request quotation |
| 10005662-1 | BSTR,HERMETIC,GAS,15 2 " W.C.,1500 SCFH, | Request quotation |
| 10014360 | SW,PRESS,INLT,BOOSTPAK | Request quotation |
| 10015430 | KIT,UPS,OUTDOOR EXTD TEMP RANGE, BOOSTPA | Request quotation |
| 10053547-1 | KIT,LIT,HERMETIC BSTR,HB,ENG | Request quotation |
| 101016641 | RTR,419 MM OD X 152.4 MM ID X 73.9 MM WI | Request quotation |
| 101016643 | RTR,495 MM OD X 152.4 MM ID X 88.9 MM WI | Request quotation |
| 12718-34 | LBL,ROT VWG PORT,HERMETIC SELD GAS BSTR | Request quotation |
| 13823 | GSKT,CORK,21.25INx17.75IN,HB4617-1 | Request quotation |
| 14222 | GSKT,CORK,23.50INx20.00IN,HB4619 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Hermetic Booster Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.