Eclipse hermetic boosters raise the pressure of suitable gases or air/gas mixtures using a motor and rotor sealed inside a steel housing.

Eclipse hermetic boosters raise the pressure of suitable gases or air/gas mixtures using a motor and rotor sealed inside a steel housing. Removing the external shaft seal avoids that leakage and wear point. The rotor can be serviced without disturbing piping; listing and material compatibility remain qualified by the handled gas.

Features & Benefits

Operating Gas Temperature
95 deg F (35 deg C)
Environmental Requirement
Ventilation, avoid sunlight/radiant heat
Outlet Connection
NPT for smaller units; ANSI 125/150 flanges for larger units
Motor Power Range
0.5 to 20 HP (model‑dependent)
Gas Compatibility
BS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases|DG - Digester gas, bio‑gas, landfill gas, sour gas
Product Variants
BS (Standard series), DG (Digester Gas series)
Product Category
Gas Pressure Booster/Blower
Outlet Positions
4 outlet positions, rotation CW/CCW|Standard = Position #1 CCW
Maximum Pressure
5 psig (344 mbar) for inlet/outlet/test pressure
Inlet Connection
NPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges
Housing Material
Steel Housing with Powder‑Coated Finish
Turndown Ratio
HB‑LC‑3316‑3/4 supports up to 50:1 turndown
Product Series
HB (Standard and Digester Gas variants)
Design Type
Hermetically sealed booster with internal rotor and motor
Motor Type
Explosion‑proof motor, Class I Group D, fan‑cooled
Frequency
60 Hz (other options by factory request)
Approvals
UL Listed (MH10098), Massachusetts Board approval
  • The hermetic motor arrangement removes shaft-seal leakage and wear.
  • The rotor can be removed without disturbing gas piping.

Applications

  • Pressure boosting of gases or air/gas mixtures compatible with aluminum and steel

Detailed capabilities

Why the motor is inside the sealed housing

The hermetic design encloses motor and rotor, removing a shaft penetration and its wear/leakage path. Sealed electrical connections and the stated junction/motor construction support the package. Gas compatibility remains limited by aluminum/steel materials and the named listing conditions. Outlet pressure is incoming pressure plus the booster's added rise, so added pressure alone is not the final line pressure.

Manufacturer reference ↗

Features and benefits

  • The hermetic motor arrangement removes shaft-seal leakage and wear.
  • The rotor can be removed without disturbing gas piping.

Manufacturer reference ↗

Published application context

  • Pressure boosting of gases or air/gas mixtures compatible with aluminum and steel

Manufacturer reference ↗

Specifications

Operating/Process Temperature Ranges

Operating Gas Temperature
95 deg F (35 deg C)

Environmental Conditions

Environmental Requirement
Ventilation, avoid sunlight/radiant heat

Connections & Interfaces

Outlet Connection
NPT for smaller units; ANSI 125/150 flanges for larger units
Inlet Connection
NPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges

Electrical Specifications

Motor Power Range
0.5 to 20 HP (model‑dependent)
Frequency
60 Hz (other options by factory request)

Applications & Compatibility

Gas Compatibility
BS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases; DG - Digester gas, bio‑gas, landfill gas, sour gas
Applications
Combustion systems requiring added gas pressure or flow stability; Increase gas pressure and flow for combustion systems

Product Overview & Classification

Product Variants
BS (Standard series), DG (Digester Gas series)
Product Series
HB (Standard and Digester Gas variants)

Overview

Product Category
Gas Pressure Booster/Blower
Design Type
Hermetically sealed booster with internal rotor and motor

Actuation, Valve & Motion Control Specifications

Outlet Positions
4 outlet positions, rotation CW/CCW; Standard = Position #1 CCW

Pressure Specifications

Maximum Pressure
5 psig (344 mbar) for inlet/outlet/test pressure

Material Specifications

Housing Material
Steel Housing with Powder‑Coated Finish

Performance, Flow & Capacity

Turndown Ratio
HB‑LC‑3316‑3/4 supports up to 50:1 turndown

Motor Specifications

Motor Type
Explosion‑proof motor, Class I Group D, fan‑cooled

Standards & Certifications

Approvals
UL Listed (MH10098), Massachusetts Board approval
Hermetic Booster — manufacturer page values
ParameterPublished value / configuration
Operating Gas Temperature95 deg F (35 deg C)
Environmental RequirementVentilation, avoid sunlight/radiant heat
Outlet ConnectionNPT for smaller units; ANSI 125/150 flanges for larger units
Inlet ConnectionNPT for models 3412, 4412, 3314, 4414; others ANSI 125/150 flanges
Motor Power Range0.5 to 20 HP (model‑dependent)
Frequency60 Hz (other options by factory request)
Gas CompatibilityBS - Air, Natural Gas, Manufactured Gas, Propane/Air, Class I Group D non‑corrosive gases; DG - Digester gas, bio‑gas, landfill gas, sour gas
ApplicationsCombustion systems requiring added gas pressure or flow stability; Increase gas pressure and flow for combustion systems
Product VariantsBS (Standard series), DG (Digester Gas series)
Product SeriesHB (Standard and Digester Gas variants)
Product CategoryGas Pressure Booster/Blower
Design TypeHermetically sealed booster with internal rotor and motor
Outlet Positions4 outlet positions, rotation CW/CCW; Standard = Position #1 CCW
Maximum Pressure5 psig (344 mbar) for inlet/outlet/test pressure
Housing MaterialSteel Housing with Powder‑Coated Finish
Turndown RatioHB‑LC‑3316‑3/4 supports up to 50:1 turndown
Motor TypeExplosion‑proof motor, Class I Group D, fan‑cooled
ApprovalsUL Listed (MH10098), Massachusetts Board approval

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10005662BSTR,15 2 " W.C.,1500 SCFH,0.25HP/115VACRequest quotation
10005662-1BSTR,HERMETIC,GAS,15 2 " W.C.,1500 SCFH,Request quotation
10014360SW,PRESS,INLT,BOOSTPAKRequest quotation
10015430KIT,UPS,OUTDOOR EXTD TEMP RANGE, BOOSTPARequest quotation
10053547-1KIT,LIT,HERMETIC BSTR,HB,ENGRequest quotation
101016641RTR,419 MM OD X 152.4 MM ID X 73.9 MM WIRequest quotation
101016643RTR,495 MM OD X 152.4 MM ID X 88.9 MM WIRequest quotation
12718-34LBL,ROT VWG PORT,HERMETIC SELD GAS BSTRRequest quotation
13823GSKT,CORK,21.25INx17.75IN,HB4617-1Request quotation
14222GSKT,CORK,23.50INx20.00IN,HB4619Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/blowers-and-boosters/hermetic-booster

Last source check: 2026-11-02

Hermetic Booster Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry