SMJ blowers serve low-temperature air-handling duties including cooling, drying, conveying and extraction. A heavy steel housing carries a balanced aluminum impeller. The fan housing permits field reconfiguration by changing rotation direction, and flanged outlets simplify handling during installation; actual capacity and pressure remain dependent on the selected blower.
Features & Benefits
- Maximum Air Temperature
- 220 deg F (104 deg C)
- Impeller Construction
- High‑strength riveted aluminum, statically and dynamically balanced
- Motor Recommendation
- Polyphase motors for 3/4 HP and above
- Filter Pressure Drop
- ~0.15 in w.c reduction with filter
- Primary Application
- Combustion systems, cooling, conveying, drying, agitation, vacuum, dust/fume exhausting
- Flow Capacity Range
- 4,600 to 209,000+ SCFH depending on model
- Air Pressure Switch
- Model A2; max 7 PSI; CSA/FM/UL
- Outlet Connection
- 3 and 4 in NPT threaded; larger sizes ANSI 125# flanged
- Outlet Positions
- #4 requires factory approval|4 outlet positions
- Maximum Pressure
- Corrected at 70 deg F inlet and 29.92 in Hg
- Housing Material
- Continuous welded, heavy-gauge steel
- Filter Capacity
- 25,000 to 250,000 SCFH
- Service Factor
- 1.15 to 1.35
- Pressure Range
- 7 to 55+ in wc depending on model
- Motor HP Range
- 1/3 to 25 HP
- Inlet Features
- OSHA‑compliant inlet grill, removable
- Product Type
- SMJ Series Turbo Blower (Centrifugal Blower)
- Inlet Sizes
- 4 to 12 in nominal pipe size, model‑dependent
- Motor Type
- 3600 rpm, standard shaft, ball‑bearing Eclipse motors
- Air Filter
- Round filters; washable/non‑washable; single/double element
- Field-reconfigurable rotation accommodates different layouts.
Applications
- Cooling
- Conveying
- Drying
- Liquid agitation
- Smoke control
- Vacuum cleaning
- Flume and dust extraction
Detailed capabilities
Field layout and balanced impeller
SMJ uses a steel body/base and a statically and dynamically balanced aluminum impeller. The revised fan housing allows field reconfiguration through the rotation arrangement, while flanges replace the older outlet coupling style. Its uses include cooling, drying, conveying and extraction at low temperature; the broad application list does not establish a hazardous-gas or high-temperature qualification.
Features and benefits
- Field-reconfigurable rotation accommodates different layouts.
Published application context
- Cooling
- Conveying
- Drying
- Liquid agitation
- Smoke control
- Vacuum cleaning
- Flume and dust extraction
Air/Exhaust/Flue Gas Temperatures
- Maximum Air Temperature
- 220 deg F (104 deg C)
Processing & Performance Metrics
- Impeller Construction
- High‑strength riveted aluminum, statically and dynamically balanced
- Flow Capacity Range
- 4,600 to 209,000+ SCFH depending on model
Motor Specifications
- Motor Recommendation
- Polyphase motors for 3/4 HP and above
- Motor HP Range
- 1/3 to 25 HP
- Motor Type
- 3600 rpm, standard shaft, ball‑bearing Eclipse motors
Pressure Specifications
- Filter Pressure Drop
- ~0.15 in w.c reduction with filter
- Maximum Pressure
- Corrected at 70 deg F inlet and 29.92 in Hg
- Pressure Range
- 7 to 55+ in wc depending on model
Applications & Compatibility
- Primary Application
- Combustion systems, cooling, conveying, drying, agitation, vacuum, dust/fume exhausting
Air & Combustion Air Specifications
- Air Pressure Switch
- Model A2; max 7 PSI; CSA/FM/UL
- Air Filter
- Round filters; washable/non‑washable; single/double element
Connections & Interfaces
- Outlet Connection
- 3 and 4 in NPT threaded; larger sizes ANSI 125# flanged
Actuation, Valve & Motion Control Specifications
- Outlet Positions
- #4 requires factory approval; 4 outlet positions
Material Specifications
- Housing Material
- Continuous welded, heavy-gauge steel
Performance Specifications
- Filter Capacity
- 25,000 to 250,000 SCFH
Operating Limits, Durability & Lifecycle
- Service Factor
- 1.15 to 1.35
Mechanical Design & Adjustment Characteristics
- Inlet Features
- OSHA‑compliant inlet grill, removable
Overview
- Product Type
- SMJ Series Turbo Blower (Centrifugal Blower)
Dimensions & Size Specifications
- Inlet Sizes
- 4 to 12 in nominal pipe size, model‑dependent
| Parameter | Published value / configuration |
|---|---|
| Maximum Air Temperature | 220 deg F (104 deg C) |
| Impeller Construction | High‑strength riveted aluminum, statically and dynamically balanced |
| Flow Capacity Range | 4,600 to 209,000+ SCFH depending on model |
| Motor Recommendation | Polyphase motors for 3/4 HP and above |
| Motor HP Range | 1/3 to 25 HP |
| Motor Type | 3600 rpm, standard shaft, ball‑bearing Eclipse motors |
| Filter Pressure Drop | ~0.15 in w.c reduction with filter |
| Maximum Pressure | Corrected at 70 deg F inlet and 29.92 in Hg |
| Pressure Range | 7 to 55+ in wc depending on model |
| Primary Application | Combustion systems, cooling, conveying, drying, agitation, vacuum, dust/fume exhausting |
| Air Pressure Switch | Model A2; max 7 PSI; CSA/FM/UL |
| Air Filter | Round filters; washable/non‑washable; single/double element |
| Outlet Connection | 3 and 4 in NPT threaded; larger sizes ANSI 125# flanged |
| Outlet Positions | #4 requires factory approval; 4 outlet positions |
| Housing Material | Continuous welded, heavy-gauge steel |
| Filter Capacity | 25,000 to 250,000 SCFH |
| Service Factor | 1.15 to 1.35 |
| Inlet Features | OSHA‑compliant inlet grill, removable |
| Product Type | SMJ Series Turbo Blower (Centrifugal Blower) |
| Inlet Sizes | 4 to 12 in nominal pipe size, model‑dependent |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10053545-1 | KIT,LIT,SMJ,ENG | Request quotation |
| 19821-4 | FLG,3 IN PIPE,288 INX425 IN IN DIMENSION | Request quotation |
| 202005 | KIT,FLG,3 IN. NPT,ASME | Request quotation |
| 202006 | KIT,FLG,4 IN. NPT,ASME | Request quotation |
| 202034 | BASE,SMJ BLWR,360 | Request quotation |
| 202056 | HSG,BLWR,SMJ 6619 5 | Request quotation |
| 202061 | HSG,BLWR,SMJ 6612 3,AND 5 | Request quotation |
| 202062 | HSG,BLWR,SMJ 8821 7 1/2,AND 10 | Request quotation |
| 202085 | KIT,MTG,6 IN. & 8 IN. FLTR/SILENCER | Request quotation |
| 202086 | KIT,MTG,10 IN. FLTR/SILENCER | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
SMJ Blower Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.