VENTITE inspirators draw combustion air into a high-pressure fuel jet through a venturi.
VENTITE inspirators draw combustion air into a high-pressure fuel jet through a venturi. Ten sizes support mixture supply to premix burner nozzles, with partial premixing also described for AIRFLO systems. The published fuel-heating-value range and pressure-dependent mixing principle must be matched to the intended burner duty.
Features & Benefits
- Primary Air Inspiration
- 50 to 80% depending on chamber pressure
- Compatible Burner Types
- STICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66)
- Air Supply Requirement
- High Pressure Version: Not required|Low Pressure Version: 5 to 60 psig compressed air
- Maximum Heat Release
- Up to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners)
- Gas Pressure Range
- High Pressure Version: 5 to 25 psig|Low Pressure Version: 0.2 in wc to 8 osi
- Outlet Connection
- Standard threaded pipe (ANSI B2.1)
- Air Inspiration
- Varies by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative)
- Pressure Range
- Up to 30 psig (higher possible with noise considerations)
- Equipment Type
- Gas‑driven inspirator/air‑gas mixer
- Capacity Range
- High Pressure Version: 250,000 to 500,000 Btu/hr|Low Pressure Version: 210,000 to 475,000 Btu/hr
- Orifice Drill
- High Pressure Version: #33 (natural gas), #43 (propane)|Low Pressure Version: #33 (natural gas), #43 (propane)
- Size Range
- 1 to 8 in
- Fuel Type
- Natural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³)
- Approvals
- ANSI Standard B2.1
- The venturi arrangement provides mixture supply without a separate mixing drive.
Applications
- Premix burner mixture supply
- Partial premixing for AIRFLO systems
Air & Combustion Air Specifications
- Primary Air Inspiration
- 50 to 80% depending on chamber pressure
- Air Supply Requirement
- High Pressure Version: Not required; Low Pressure Version: 5 to 60 psig compressed air
- Air Inspiration
- Varies by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative)
Applications & Compatibility
- Compatible Burner Types
- STICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66)
- Applications
- Open‑port burners, immersion tubes, ovens, furnaces, air heaters; Uses fuel gas pressure to induce and mix primary combustion air
Performance, Flow & Capacity
- Maximum Heat Release
- Up to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners)
Pressure Specifications
- Gas Pressure Range
- High Pressure Version: 5 to 25 psig; Low Pressure Version: 0.2 in wc to 8 osi
- Pressure Range
- Up to 30 psig (higher possible with noise considerations)
Connections & Interfaces
- Outlet Connection
- Standard threaded pipe (ANSI B2.1)
Product Overview & Classification
- Equipment Type
- Gas‑driven inspirator/air‑gas mixer
Processing & Performance Metrics
- Capacity Range
- High Pressure Version: 250,000 to 500,000 Btu/hr; Low Pressure Version: 210,000 to 475,000 Btu/hr
Actuation, Valve & Motion Control Specifications
- Orifice Drill
- High Pressure Version: #33 (natural gas), #43 (propane); Low Pressure Version: #33 (natural gas), #43 (propane)
Dimensions & Size Specifications
- Size Range
- 1 to 8 in
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³)
Standards & Certifications
- Approvals
- ANSI Standard B2.1
| Parameter | Published value / configuration |
|---|---|
| Primary Air Inspiration | 50 to 80% depending on chamber pressure |
| Air Supply Requirement | High Pressure Version: Not required; Low Pressure Version: 5 to 60 psig compressed air |
| Air Inspiration | Varies by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative) |
| Compatible Burner Types | STICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66) |
| Applications | Open‑port burners, immersion tubes, ovens, furnaces, air heaters; Uses fuel gas pressure to induce and mix primary combustion air |
| Maximum Heat Release | Up to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners) |
| Gas Pressure Range | High Pressure Version: 5 to 25 psig; Low Pressure Version: 0.2 in wc to 8 osi |
| Pressure Range | Up to 30 psig (higher possible with noise considerations) |
| Outlet Connection | Standard threaded pipe (ANSI B2.1) |
| Equipment Type | Gas‑driven inspirator/air‑gas mixer |
| Capacity Range | High Pressure Version: 250,000 to 500,000 Btu/hr; Low Pressure Version: 210,000 to 475,000 Btu/hr |
| Orifice Drill | High Pressure Version: #33 (natural gas), #43 (propane); Low Pressure Version: #33 (natural gas), #43 (propane) |
| Size Range | 1 to 8 in |
| Fuel Type | Natural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³) |
| Approvals | ANSI Standard B2.1 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1.25VENTITE/NZL | 1.25" VENTITE NZL | Request quotation |
| 1.5VENTITE/NZL | 1.5" VENTITE NZL | Request quotation |
| 1042548 | ZINC CORP END PLT ASY | Request quotation |
| 1047912 | 2" STR HP AL HAND TRCH L/+ | Request quotation |
| 1115326 | 2" 90DEG HP AL HAND TRCH | Request quotation |
| 12598 | 2" STR HP AL HAND TRCH | Request quotation |
| 12599 | 2" 45DEG HP AL HAND TRCH | Request quotation |
| 12902 | 2" STR LP AL HAND TRCH | Request quotation |
| 12903 | 2" 45DEG LP AL HAND TRCH | Request quotation |
| 12904 | 2" 90DEG LP AL HAND TRCH | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
VENTITE Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.