Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pre-Mix Equipment

VENTITE™ Inspirators

VENTITE inspirators draw combustion air into a high-pressure fuel jet through a venturi.

VENTITE inspirators draw combustion air into a high-pressure fuel jet through a venturi. Ten sizes support mixture supply to premix burner nozzles, with partial premixing also described for AIRFLO systems. The published fuel-heating-value range and pressure-dependent mixing principle must be matched to the intended burner duty.

Features & Benefits

Primary Air Inspiration
50 to 80% depending on chamber pressure
Compatible Burner Types
STICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66)
Air Supply Requirement
High Pressure Version: Not required|Low Pressure Version: 5 to 60 psig compressed air
Maximum Heat Release
Up to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners)
Gas Pressure Range
High Pressure Version: 5 to 25 psig|Low Pressure Version: 0.2 in wc to 8 osi
Outlet Connection
Standard threaded pipe (ANSI B2.1)
Air Inspiration
Varies by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative)
Pressure Range
Up to 30 psig (higher possible with noise considerations)
Equipment Type
Gas‑driven inspirator/air‑gas mixer
Capacity Range
High Pressure Version: 250,000 to 500,000 Btu/hr|Low Pressure Version: 210,000 to 475,000 Btu/hr
Orifice Drill
High Pressure Version: #33 (natural gas), #43 (propane)|Low Pressure Version: #33 (natural gas), #43 (propane)
Size Range
1 to 8 in
Fuel Type
Natural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³)
Approvals
ANSI Standard B2.1
  • The venturi arrangement provides mixture supply without a separate mixing drive.

Applications

  • Premix burner mixture supply
  • Partial premixing for AIRFLO systems

Specifications

Air & Combustion Air Specifications

Primary Air Inspiration
50 to 80% depending on chamber pressure
Air Supply Requirement
High Pressure Version: Not required; Low Pressure Version: 5 to 60 psig compressed air
Air Inspiration
Varies by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative)

Applications & Compatibility

Compatible Burner Types
STICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66)
Applications
Open‑port burners, immersion tubes, ovens, furnaces, air heaters; Uses fuel gas pressure to induce and mix primary combustion air

Performance, Flow & Capacity

Maximum Heat Release
Up to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners)

Pressure Specifications

Gas Pressure Range
High Pressure Version: 5 to 25 psig; Low Pressure Version: 0.2 in wc to 8 osi
Pressure Range
Up to 30 psig (higher possible with noise considerations)

Connections & Interfaces

Outlet Connection
Standard threaded pipe (ANSI B2.1)

Product Overview & Classification

Equipment Type
Gas‑driven inspirator/air‑gas mixer

Processing & Performance Metrics

Capacity Range
High Pressure Version: 250,000 to 500,000 Btu/hr; Low Pressure Version: 210,000 to 475,000 Btu/hr

Actuation, Valve & Motion Control Specifications

Orifice Drill
High Pressure Version: #33 (natural gas), #43 (propane); Low Pressure Version: #33 (natural gas), #43 (propane)

Dimensions & Size Specifications

Size Range
1 to 8 in

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³)

Standards & Certifications

Approvals
ANSI Standard B2.1
VENTITE™ Inspirators — manufacturer page values
ParameterPublished value / configuration
Primary Air Inspiration50 to 80% depending on chamber pressure
Air Supply RequirementHigh Pressure Version: Not required; Low Pressure Version: 5 to 60 psig compressed air
Air InspirationVaries by chamber pressure: 80% (balanced), 65% (slightly negative), 50% (high negative)
Compatible Burner TypesSTICKTITE™, Sealed Nozzles (SN), LINOFLAME® (A, B, VF), AIRFLO® (Series 66)
ApplicationsOpen‑port burners, immersion tubes, ovens, furnaces, air heaters; Uses fuel gas pressure to induce and mix primary combustion air
Maximum Heat ReleaseUp to 525,000 Btu/hr per lineal foot (LINOFLAME® Burners)
Gas Pressure RangeHigh Pressure Version: 5 to 25 psig; Low Pressure Version: 0.2 in wc to 8 osi
Pressure RangeUp to 30 psig (higher possible with noise considerations)
Outlet ConnectionStandard threaded pipe (ANSI B2.1)
Equipment TypeGas‑driven inspirator/air‑gas mixer
Capacity RangeHigh Pressure Version: 250,000 to 500,000 Btu/hr; Low Pressure Version: 210,000 to 475,000 Btu/hr
Orifice DrillHigh Pressure Version: #33 (natural gas), #43 (propane); Low Pressure Version: #33 (natural gas), #43 (propane)
Size Range1 to 8 in
Fuel TypeNatural Gas (1000 Btu/ft³), Propane (2500 Btu/ft³)
ApprovalsANSI Standard B2.1

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1.25VENTITE/NZL1.25" VENTITE NZLRequest quotation
1.5VENTITE/NZL1.5" VENTITE NZLRequest quotation
1042548ZINC CORP END PLT ASYRequest quotation
10479122" STR HP AL HAND TRCH L/+Request quotation
11153262" 90DEG HP AL HAND TRCHRequest quotation
125982" STR HP AL HAND TRCHRequest quotation
125992" 45DEG HP AL HAND TRCHRequest quotation
129022" STR LP AL HAND TRCHRequest quotation
129032" 45DEG LP AL HAND TRCHRequest quotation
129042" 90DEG LP AL HAND TRCHRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pre-mix-equipment/ventite-inspirators

Last source check: 2026-11-02

VENTITE Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry