MG tubes combine fuel-jet, vortex and swirl mixing at low air and fuel pressures.

MG tubes combine fuel-jet, vortex and swirl mixing at low air and fuel pressures. Standard and special inserts address natural gas, LPG and other gas combinations for single or multiple burners. Flanged connections and carbon-steel or optional stainless construction support piping requirements across the published size and capacity range.

Features & Benefits

Series
Series “MG”
Combustion Air Differential Pressure
Δp between upstream air and downstream mixture pressure
Maintenance Interval
Visual inspections + annual thorough check
Air Pressure Drop
Up to 10.63 in wc
Connection Type
Air Inlet, Mixture Outlet - Flanged PN10 (DIN 2576), Gas Inlet ≤ 2 - Threaded (ISO 7), Gas Inlet > 2 in - Flanged PN10 (DIN 2576)
Turndown Ratio
1:5 of max rated flow
Nominal Sizes
MG‑50 to MG‑400
Paint Finish
Indoor corrosion protection; outdoor finish optional
Construction
Fitting - Carbon Steel, Flexible Hose - Stainless steel with malleable cast iron nipples, Body - 100% stainless steel (AISI 304 - 1.4301 and others)
Air Factor
n = 1.0 (stoich), n = 1.1+, supported
Fuel Type
Natural Gas, Propane, Butane, LPG
Approvals
PN10 DIN2576
Material
Seamless carbon steel tubes and fittings
  • Combined mixing mechanisms promote a homogeneous mixture.

Applications

  • Air/fuel mixing for single- or multiple-burner installations

Specifications

Overview

Series
Series “MG”

Pressure Specifications

Combustion Air Differential Pressure
Δp between upstream air and downstream mixture pressure

Electrical Specifications

Maintenance Interval
Visual inspections + annual thorough check

Air & Combustion Air Specifications

Air Pressure Drop
Up to 10.63 in wc
Air Factor
n = 1.0 (stoich), n = 1.1+, supported

Connections & Interfaces

Connection Type
Air Inlet, Mixture Outlet - Flanged PN10 (DIN 2576), Gas Inlet ≤ 2 - Threaded (ISO 7), Gas Inlet > 2 in - Flanged PN10 (DIN 2576)

Performance, Flow & Capacity

Turndown Ratio
1:5 of max rated flow

Dimensions & Size Specifications

Nominal Sizes
MG‑50 to MG‑400

Mechanical Design & Hardware Details

Paint Finish
Indoor corrosion protection; outdoor finish optional

Product Overview & Classification

Construction
Fitting - Carbon Steel, Flexible Hose - Stainless steel with malleable cast iron nipples, Body - 100% stainless steel (AISI 304 - 1.4301 and others)

Applications & Compatibility

Applications
Industrial combustion systems

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane, LPG

Standards & Certifications

Approvals
PN10 DIN2576

Material Specifications

Material
Seamless carbon steel tubes and fittings
MG Mixing Tubes — manufacturer page values
ParameterPublished value / configuration
SeriesSeries “MG”
Combustion Air Differential PressureΔp between upstream air and downstream mixture pressure
Maintenance IntervalVisual inspections + annual thorough check
Air Pressure DropUp to 10.63 in wc
Air Factorn = 1.0 (stoich), n = 1.1+, supported
Connection TypeAir Inlet, Mixture Outlet - Flanged PN10 (DIN 2576), Gas Inlet ≤ 2 - Threaded (ISO 7), Gas Inlet > 2 in - Flanged PN10 (DIN 2576)
Turndown Ratio1:5 of max rated flow
Nominal SizesMG‑50 to MG‑400
Paint FinishIndoor corrosion protection; outdoor finish optional
ConstructionFitting - Carbon Steel, Flexible Hose - Stainless steel with malleable cast iron nipples, Body - 100% stainless steel (AISI 304 - 1.4301 and others)
ApplicationsIndustrial combustion systems
Fuel TypeNatural Gas, Propane, Butane, LPG
ApprovalsPN10 DIN2576
MaterialSeamless carbon steel tubes and fittings

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
301626_VMIXER MG-150 NATURAL GASRequest quotation
301731_VMIXER MG-300 NATURAL GASRequest quotation
MG-100AIR INLET MIXTURE OUTLET CONN.DN100/PN10Request quotation
MG-125AIR INLET MIXTURE OUTLET CONN.DN125/PN10Request quotation
MG-150AIR INLET MIXTURE OUTLET CONN.DN150/PN10Request quotation
MG-200AIR INLET MIXTURE OUTLET CONN.DN200/PN10Request quotation
MG-250AIR INLET MIXTURE OUTLET CONN.DN250/PN10Request quotation
MG-300AIR INLET MIXTURE OUTLET CONN.DN300/PN10Request quotation
MG-400AIR INLET MIXTURE OUTLET CONN.DN400/PN10Request quotation
MG-65AIR INLET MIXTURE OUTLET CONN. DN65/PN10Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pre-mix-equipment/mg-mixing-tubes

Last source check: 2026-11-02

MG Mixing Tubes Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry