Pre-Mix Equipment
HG Mixing Tubes
HG mixing tubes use higher gas pressure to blend fuel and air while allowing a lower-pressure combustion-air blower.
HG mixing tubes use higher gas pressure to blend fuel and air while allowing a lower-pressure combustion-air blower. Combined with MICRO-RATIO control, they provide localized mixture supply to one or several burners. The source distinguishes these high-pressure mixing tubes from LG and MULTI-RATIO equipment intended for low-pressure gas.
Features & Benefits
- Series
- HG
- Combustion Air Differential Pressure
- Measured at HG inlet
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
- Gas Orifice Drill Size
- Stamped on casting
- Gas Orifice Quantity
- Size‑dependent (fixed per HG size)
- Air Velocity Range
- 500 to 1500 SFPM (for air heating applications)
- Connection Type
- NPT (ANSI B2.1)
- Turndown Ratio
- Up to 15:1 (with natural gas)
- Nominal Sizes
- 2 in, 3 in, 4 in, 6 in, 8 in
- Mixer Type
- Venturi-type premixing tube
- Fuel Type
- Natural Gas, Propane, Butane
- Approvals
- ANSI Standard B2.1
- Material
- Cast Metal
- Using gas-jet energy permits a lower-pressure air blower.
Applications
- Premix supply to single or multiple burners using higher-pressure gas
Detailed capabilities
Higher-pressure gas supplies mixing energy
HG uses gas-jet momentum to blend fuel with air, allowing a lower-pressure combustion-air blower than an arrangement that relies on blower pressure alone. A MICRO-RATIO valve sets preproportioning for localized single- or multiple-burner supply. Most clean gases are described. This high-pressure operating principle distinguishes HG from the low-pressure LG/MULTI-RATIO products named alongside it.
Features and benefits
- Using gas-jet energy permits a lower-pressure air blower.
Published application context
- Premix supply to single or multiple burners using higher-pressure gas
Overview
- Series
- HG
Pressure Specifications
- Combustion Air Differential Pressure
- Measured at HG inlet
Air/Exhaust/Flue Gas Temperatures
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
Dimensions & Size Specifications
- Gas Orifice Drill Size
- Stamped on casting
- Nominal Sizes
- 2 in, 3 in, 4 in, 6 in, 8 in
Combustion, Mixing & Fuel Dynamics
- Gas Orifice Quantity
- Size‑dependent (fixed per HG size)
Air & Combustion Air Specifications
- Air Velocity Range
- 500 to 1500 SFPM (for air heating applications)
Connections & Interfaces
- Connection Type
- NPT (ANSI B2.1)
Performance, Flow & Capacity
- Turndown Ratio
- Up to 15:1 (with natural gas)
Applications & Compatibility
- Applications
- Burners: LINOFLAME®, INFRAWAVE®, AIRFLO®, COMBUSTIFUME®, LO‑NOX™, Nozzle: STICKTITE™, Series “SN”
Mixing & Combustion Sub‑Components
- Mixer Type
- Venturi-type premixing tube
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane
Standards & Certifications
- Approvals
- ANSI Standard B2.1
Material Specifications
- Material
- Cast Metal
| Parameter | Published value / configuration |
|---|---|
| Series | HG |
| Combustion Air Differential Pressure | Measured at HG inlet |
| Maximum Return Air Temperature | 500 deg F (260 deg C) |
| Gas Orifice Drill Size | Stamped on casting |
| Nominal Sizes | 2 in, 3 in, 4 in, 6 in, 8 in |
| Gas Orifice Quantity | Size‑dependent (fixed per HG size) |
| Air Velocity Range | 500 to 1500 SFPM (for air heating applications) |
| Connection Type | NPT (ANSI B2.1) |
| Turndown Ratio | Up to 15:1 (with natural gas) |
| Applications | Burners: LINOFLAME®, INFRAWAVE®, AIRFLO®, COMBUSTIFUME®, LO‑NOX™, Nozzle: STICKTITE™, Series “SN” |
| Mixer Type | Venturi-type premixing tube |
| Fuel Type | Natural Gas, Propane, Butane |
| Approvals | ANSI Standard B2.1 |
| Material | Cast Metal |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 012139E | 2" SERIES HG MIXING TUBE DIN | Request quotation |
| 012140E | 3" SERIES HG MIXING TUBE DIN | Request quotation |
| 015673E | 6" SERIES HG MIXING TUBE DIN | Request quotation |
| 021535E | 4" SERIES HG MIXING TUBE DIN | Request quotation |
| 11984 | MR-100-22 MULTI-RATIO MXR | Request quotation |
| 11985 | MR-100-25 MULTI-RATIO MXR | Request quotation |
| 11988 | MR-125-28 MULTI-RATIO MXR | Request quotation |
| 11994 | MR-150-51 MULTI-RATIO MXR | Request quotation |
| 11999 | MR-200-66 MULTI-RATIO MXR | Request quotation |
| 301622 | MIXER MG-50 NATURAL GAS | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HG Mixing Tubes Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.