MULTI-RATIO mixers supply blended, preproportioned air and clean low-pressure gas to MAXON premix burners.
MULTI-RATIO mixers supply blended, preproportioned air and clean low-pressure gas to MAXON premix burners. Capacity choices support localized single- or multiple-burner systems. The manufacturer groups their low-pressure function with LG mixing tubes and distinguishes it from HG tubes, which use the energy of higher gas pressure.
Features & Benefits
- Air Differential Pressure Range
- Measured at mixer inlet
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
- Compatible Burner Types
- STICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO®
- Pressure Sensitivity
- Back pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15%
- Air Velocity Range
- 500 to 1500 SFPM for recirculating systems
- Primary Function
- Accurately mixes and controls air and gas to maintain a consistent ratio
- Mixing Principle
- Mechanical proportional control using cam‑driven air and gas valves
- Mixing Accuracy
- Designed for stable combustion over wide firing range
- Control Method
- Mechanical linkage (cam springs and plunger assembly)
- Product Type
- Proportional air/gas premixing valve
- Construction
- Metallic mixer body with internal air and gas control components
- Mixer Type
- LG = Mixing Tube, RM = MULTI-RATIO™ Mixer
- Fuel Type
- Natural Gas, Propane, Butane
- Approvals
- ANSI Standard B2.1
Applications
- Low-pressure gas premixing for MAXON burners
Detailed capabilities
Localized mixture supply to one or several burners
MULTI-RATIO blends preproportioned air and clean low-pressure gas for MAXON premix systems. Capacity options permit localized mixing close to a single burner or a burner group. The source contrasts this low-pressure function with HG's use of higher gas pressure, so these references describe different mixing approaches rather than alternate names for the same pressure requirement.
Published application context
- Low-pressure gas premixing for MAXON burners
Air & Combustion Air Specifications
- Air Differential Pressure Range
- Measured at mixer inlet
- Air Velocity Range
- 500 to 1500 SFPM for recirculating systems
Air/Exhaust/Flue Gas Temperatures
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
Applications & Compatibility
- Compatible Burner Types
- STICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO®
- Applications
- Industrial Burners, Ovens, Furnaces, Kilns, Air Heaters
Pressure Specifications
- Pressure Sensitivity
- Back pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15%
Product Overview & Classification
- Primary Function
- Accurately mixes and controls air and gas to maintain a consistent ratio
- Construction
- Metallic mixer body with internal air and gas control components
Combustion, Mixing & Fuel Dynamics
- Mixing Principle
- Mechanical proportional control using cam‑driven air and gas valves
- Mixing Accuracy
- Designed for stable combustion over wide firing range
Control, Logic & Functional Behavior
- Control Method
- Mechanical linkage (cam springs and plunger assembly)
Overview
- Product Type
- Proportional air/gas premixing valve
Mixing & Combustion Sub‑Components
- Mixer Type
- LG = Mixing Tube, RM = MULTI-RATIO™ Mixer
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane
Standards & Certifications
- Approvals
- ANSI Standard B2.1
| Parameter | Published value / configuration |
|---|---|
| Air Differential Pressure Range | Measured at mixer inlet |
| Air Velocity Range | 500 to 1500 SFPM for recirculating systems |
| Maximum Return Air Temperature | 500 deg F (260 deg C) |
| Compatible Burner Types | STICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO® |
| Applications | Industrial Burners, Ovens, Furnaces, Kilns, Air Heaters |
| Pressure Sensitivity | Back pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15% |
| Primary Function | Accurately mixes and controls air and gas to maintain a consistent ratio |
| Construction | Metallic mixer body with internal air and gas control components |
| Mixing Principle | Mechanical proportional control using cam‑driven air and gas valves |
| Mixing Accuracy | Designed for stable combustion over wide firing range |
| Control Method | Mechanical linkage (cam springs and plunger assembly) |
| Product Type | Proportional air/gas premixing valve |
| Mixer Type | LG = Mixing Tube, RM = MULTI-RATIO™ Mixer |
| Fuel Type | Natural Gas, Propane, Butane |
| Approvals | ANSI Standard B2.1 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 00824 | 4" SHTR | Request quotation |
| 00831 | 4" SPUD | Request quotation |
| 00909 | 2",3" END PLT | Request quotation |
| 00910 | 2",3" SHTR | Request quotation |
| 00911 | 2" VENTURI TB | Request quotation |
| 00926 | 1.5" VENTURI TB | Request quotation |
| 00928 | 1" VENTURI TB | Request quotation |
| 00936 | 2",2.5" SPUD | Request quotation |
| 012007 | MR300-106 MULTIRATIO MIXER ANS | Request quotation |
| 01764 | 1"-1.5" END PLT | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Multi Ratio Mixers Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.