Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pre-Mix Equipment

MULTI-RATIO™ Mixers

MULTI-RATIO mixers supply blended, preproportioned air and clean low-pressure gas to MAXON premix burners.

MULTI-RATIO mixers supply blended, preproportioned air and clean low-pressure gas to MAXON premix burners. Capacity choices support localized single- or multiple-burner systems. The manufacturer groups their low-pressure function with LG mixing tubes and distinguishes it from HG tubes, which use the energy of higher gas pressure.

Features & Benefits

Air Differential Pressure Range
Measured at mixer inlet
Maximum Return Air Temperature
500 deg F (260 deg C)
Compatible Burner Types
STICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO®
Pressure Sensitivity
Back pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15%
Air Velocity Range
500 to 1500 SFPM for recirculating systems
Primary Function
Accurately mixes and controls air and gas to maintain a consistent ratio
Mixing Principle
Mechanical proportional control using cam‑driven air and gas valves
Mixing Accuracy
Designed for stable combustion over wide firing range
Control Method
Mechanical linkage (cam springs and plunger assembly)
Product Type
Proportional air/gas premixing valve
Construction
Metallic mixer body with internal air and gas control components
Mixer Type
LG = Mixing Tube, RM = MULTI-RATIO™ Mixer
Fuel Type
Natural Gas, Propane, Butane
Approvals
ANSI Standard B2.1

Applications

  • Low-pressure gas premixing for MAXON burners

Detailed capabilities

Localized mixture supply to one or several burners

MULTI-RATIO blends preproportioned air and clean low-pressure gas for MAXON premix systems. Capacity options permit localized mixing close to a single burner or a burner group. The source contrasts this low-pressure function with HG's use of higher gas pressure, so these references describe different mixing approaches rather than alternate names for the same pressure requirement.

Manufacturer reference ↗

Published application context

  • Low-pressure gas premixing for MAXON burners

Manufacturer reference ↗

Specifications

Air & Combustion Air Specifications

Air Differential Pressure Range
Measured at mixer inlet
Air Velocity Range
500 to 1500 SFPM for recirculating systems

Air/Exhaust/Flue Gas Temperatures

Maximum Return Air Temperature
500 deg F (260 deg C)

Applications & Compatibility

Compatible Burner Types
STICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO®
Applications
Industrial Burners, Ovens, Furnaces, Kilns, Air Heaters

Pressure Specifications

Pressure Sensitivity
Back pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15%

Product Overview & Classification

Primary Function
Accurately mixes and controls air and gas to maintain a consistent ratio
Construction
Metallic mixer body with internal air and gas control components

Combustion, Mixing & Fuel Dynamics

Mixing Principle
Mechanical proportional control using cam‑driven air and gas valves
Mixing Accuracy
Designed for stable combustion over wide firing range

Control, Logic & Functional Behavior

Control Method
Mechanical linkage (cam springs and plunger assembly)

Overview

Product Type
Proportional air/gas premixing valve

Mixing & Combustion Sub‑Components

Mixer Type
LG = Mixing Tube, RM = MULTI-RATIO™ Mixer

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane

Standards & Certifications

Approvals
ANSI Standard B2.1
MULTI-RATIO™ Mixers — manufacturer page values
ParameterPublished value / configuration
Air Differential Pressure RangeMeasured at mixer inlet
Air Velocity Range500 to 1500 SFPM for recirculating systems
Maximum Return Air Temperature500 deg F (260 deg C)
Compatible Burner TypesSTICKTITE™, SEALED NOZZLE, LINOFLAME® (A, B, VF), INFRAWAVE®, LO-NOX™, COMBUSTIFUME®, AIRFLO®
ApplicationsIndustrial Burners, Ovens, Furnaces, Kilns, Air Heaters
Pressure SensitivityBack pressure of +0.15 in wc reduces capacity by 5%; +0.25 in wc by 15%
Primary FunctionAccurately mixes and controls air and gas to maintain a consistent ratio
ConstructionMetallic mixer body with internal air and gas control components
Mixing PrincipleMechanical proportional control using cam‑driven air and gas valves
Mixing AccuracyDesigned for stable combustion over wide firing range
Control MethodMechanical linkage (cam springs and plunger assembly)
Product TypeProportional air/gas premixing valve
Mixer TypeLG = Mixing Tube, RM = MULTI-RATIO™ Mixer
Fuel TypeNatural Gas, Propane, Butane
ApprovalsANSI Standard B2.1

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
008244" SHTRRequest quotation
008314" SPUDRequest quotation
009092",3" END PLTRequest quotation
009102",3" SHTRRequest quotation
009112" VENTURI TBRequest quotation
009261.5" VENTURI TBRequest quotation
009281" VENTURI TBRequest quotation
009362",2.5" SPUDRequest quotation
012007MR300-106 MULTIRATIO MIXER ANSRequest quotation
017641"-1.5" END PLTRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pre-mix-equipment/multi-ratio-mixers

Last source check: 2026-11-02

Multi Ratio Mixers Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry