Pre-Mix Equipment
Mini Pre-Mix Blower Mixers
Mini PREMIX blower mixers combine a blower, adjustable air shutter and adjustable fuel orifice.
Mini PREMIX blower mixers combine a blower, adjustable air shutter and adjustable fuel orifice. Fuel flow can be matched to airflow for ratio firing or shifted toward oxidizing or reducing conditions within the connected burner's limits. The product is a mixture-supply assembly rather than a complete burner-management system.
Features & Benefits
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
- Back Pressure Limitation
- Not suitable above specified back pressure limits
- Fresh Air Requirement
- ≥25 SCFM per 100,000 Btu/hr
- Burner Compatibility
- STICKTITE™, PILOTPAK™, SN Sealed Nozzles, LINOFLAME® Burners, INFRAWAVE®
- Gas Pressure Range
- On‑ratio: ~3 in-wc; Rich firing: ≥6 in-wc (open air only)
- Air Velocity Range
- 500 to 1500 SFPM (for air heating)
- Miniature Mixers
- M-series (no ratio valve, for on-off firing)
- Capacity Range
- Up to ~500,000 Btu/hr (model dependent)
- Motor Voltage
- Multiple voltages available (model dependent)
- Mixing Method
- Forced‑draft premix using integral blower
- Product Type
- Compact air/gas premixing blower mixer
- Flame Length
- Varies by nozzle and firing condition
- Motor Type
- Totally enclosed electric motor
- Mixer Type
- M, PL, PM, PH
- Fuel Type
- Natural Gas (standard), Propane, Butane
- Approvals
- ANSI Standard B2.1
- Fuel flow can be matched to airflow for ratio firing or shifted toward oxidizing or reducing conditions within the connected burner's limits.
Applications
- Air/fuel mixture supply to compatible premix burners
Air/Exhaust/Flue Gas Temperatures
- Maximum Return Air Temperature
- 500 deg F (260 deg C)
Pressure Specifications
- Back Pressure Limitation
- Not suitable above specified back pressure limits
- Gas Pressure Range
- On‑ratio: ~3 in-wc; Rich firing: ≥6 in-wc (open air only)
Air & Combustion Air Specifications
- Fresh Air Requirement
- ≥25 SCFM per 100,000 Btu/hr
- Air Velocity Range
- 500 to 1500 SFPM (for air heating)
Applications & Compatibility
- Burner Compatibility
- STICKTITE™, PILOTPAK™, SN Sealed Nozzles, LINOFLAME® Burners, INFRAWAVE®
- Applications
- On‑off fired systems, small burners, compact heating systems
Product Design & Configuration
- Miniature Mixers
- M-series (no ratio valve, for on-off firing)
Processing & Performance Metrics
- Capacity Range
- Up to ~500,000 Btu/hr (model dependent)
Electrical Specifications
- Motor Voltage
- Multiple voltages available (model dependent)
Combustion, Mixing & Fuel Dynamics
- Mixing Method
- Forced‑draft premix using integral blower
Overview
- Product Type
- Compact air/gas premixing blower mixer
Burner/Flame‑Related Lengths
- Flame Length
- Varies by nozzle and firing condition
Motor Specifications
- Motor Type
- Totally enclosed electric motor
Mixing & Combustion Sub‑Components
- Mixer Type
- M, PL, PM, PH
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas (standard), Propane, Butane
Standards & Certifications
- Approvals
- ANSI Standard B2.1
| Parameter | Published value / configuration |
|---|---|
| Maximum Return Air Temperature | 500 deg F (260 deg C) |
| Back Pressure Limitation | Not suitable above specified back pressure limits |
| Gas Pressure Range | On‑ratio: ~3 in-wc; Rich firing: ≥6 in-wc (open air only) |
| Fresh Air Requirement | ≥25 SCFM per 100,000 Btu/hr |
| Air Velocity Range | 500 to 1500 SFPM (for air heating) |
| Burner Compatibility | STICKTITE™, PILOTPAK™, SN Sealed Nozzles, LINOFLAME® Burners, INFRAWAVE® |
| Applications | On‑off fired systems, small burners, compact heating systems |
| Miniature Mixers | M-series (no ratio valve, for on-off firing) |
| Capacity Range | Up to ~500,000 Btu/hr (model dependent) |
| Motor Voltage | Multiple voltages available (model dependent) |
| Mixing Method | Forced‑draft premix using integral blower |
| Product Type | Compact air/gas premixing blower mixer |
| Flame Length | Varies by nozzle and firing condition |
| Motor Type | Totally enclosed electric motor |
| Mixer Type | M, PL, PM, PH |
| Fuel Type | Natural Gas (standard), Propane, Butane |
| Approvals | ANSI Standard B2.1 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
9 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1033976 | GAYLORD M500 MINI PREMIX W/+ | Request quotation |
| 1034008 | REED OVEN M250 MINI PREMIX+ | Request quotation |
| 1037911 | M100 MINI PREMIX ASY,L/MTR | Request quotation |
| 18410I | MXN flame Rod | Request quotation |
| 44353 | M100 MINI PREMIX ASY | Request quotation |
| 44354 | M250 MINI PREMIX ASY | Request quotation |
| 44355 | M500 MINI PREMIX ASY | Request quotation |
| 50117975-001 | M500 MINI PREMIX ASY W/3PH MTR | Request quotation |
| 53505 | M-500 MINI PREMIX STK ASY | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Mini Pre-Mix Blower Mixers product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.