Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Hauck Asphalt Burners

StarJet

StarJet recirculates hot gases to stabilize combustion without a refractory ignition tile or separate combustion chamber.

StarJet recirculates hot gases to stabilize combustion without a refractory ignition tile or separate combustion chamber. The flame can be adjusted from a short drum-mixing shape to a longer profile. Broad turndown supports reduced-production duties, and the listed fuels include oils, natural gas, liquid propane and landfill gas.

Features & Benefits

Blower Pressure Options
24 osig or 36 osig
Multi‑Fuel Operation
Any two fuels in combination (except liquid LP and fuel oil together)
Air Entry Orientation
45 deg air entry at 3, 6, 9, or 12 o’clock
Combustion Principle
Internal hot‑gas recirculation for flame stability
Turndown Capability
Wide turndown ratio (useful for low production rates)
Primary Application
Rotary drying (asphalt production)
Maximum Capacity
Approximately 12 to 200 MMBTU/hr (model dependent)
Supported Fuels
Heavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas
Product Series
SJ/SJC
Burner Design
Open‑fired, no combustion chamber required
Product Type
Open‑fired rotary dryer burner
Flame Type
High‑intensity, rapid heat release
Approvals
NFPA‑compliant fuel manifolds
  • Recirculation stabilizes the flame without a refractory ignition tile.
  • Wide turndown supports lower production rates.

Applications

  • Drum mixing
  • Reduced-production and cold-patch asphalt duties

Specifications

Overview

Models
SJ075 to SJ980
Product Type
Open‑fired rotary dryer burner

Pressure Specifications

Blower Pressure Options
24 osig or 36 osig

Fuel, Gas & Media Specifications

Multi‑Fuel Operation
Any two fuels in combination (except liquid LP and fuel oil together)

Air & Combustion Air Specifications

Air Entry Orientation
45 deg air entry at 3, 6, 9, or 12 o’clock

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Internal hot‑gas recirculation for flame stability

Processing & Performance Metrics

Turndown Capability
Wide turndown ratio (useful for low production rates)
Maximum Capacity
Approximately 12 to 200 MMBTU/hr (model dependent)

Applications & Compatibility

Primary Application
Rotary drying (asphalt production)

Actuation, Valve & Motion Control Specifications

Supported Fuels
Heavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas

Product Overview & Classification

Product Series
SJ/SJC

Product Design & Configuration

Burner Design
Open‑fired, no combustion chamber required

Ignition, Flame & Supervision Specifications

Flame Type
High‑intensity, rapid heat release

Standards & Certifications

Approvals
NFPA‑compliant fuel manifolds
StarJet — manufacturer page values
ParameterPublished value / configuration
ModelsSJ075 to SJ980
Product TypeOpen‑fired rotary dryer burner
Blower Pressure Options24 osig or 36 osig
Multi‑Fuel OperationAny two fuels in combination (except liquid LP and fuel oil together)
Air Entry Orientation45 deg air entry at 3, 6, 9, or 12 o’clock
Combustion PrincipleInternal hot‑gas recirculation for flame stability
Turndown CapabilityWide turndown ratio (useful for low production rates)
Maximum CapacityApproximately 12 to 200 MMBTU/hr (model dependent)
Primary ApplicationRotary drying (asphalt production)
Supported FuelsHeavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas
Product SeriesSJ/SJC
Burner DesignOpen‑fired, no combustion chamber required
Flame TypeHigh‑intensity, rapid heat release
ApprovalsNFPA‑compliant fuel manifolds

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
101029648MNFLD ASSY,GAS,SJ200 260,9 & 12 O CLOCKRequest quotation
101029649MNFLD ASSY,GAS,SJ200 260,3 & 6 O CLOCK ARequest quotation
101029650KIT,SJ4200 4260,GAS VLV MTRG,3 & 6 O CLORequest quotation
101029651KIT,SJ4200 4260,GAS VLV MTRG,9 & 12 O CLRequest quotation
101029710KIT,SJ4360 4580,GAS VLV,3 AND 6 OCLOCK BRequest quotation
101029712KIT,SJ4360 4580,GAS VLV,9 AND 12 OCLOCKRequest quotation
101029713MNFLD, ASY,SJ 360 580 90°,3 AND 6 OCLOCKRequest quotation
101031090MNFLD,LP,SJ4520 & 4580,3 AND 6 OCLOCK,WRequest quotation
101031091MNFLD,LP,SJ4520 & 4580,9 AND 12 OCLOCK,WRequest quotation
101031350MNFLD,ASY,OIL,SJ4360,3 AND 6 OCLOCKRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/hauck-asphalt-burners/starjet

Last source check: 2026-11-02

StarJet Primary Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry