Hauck Asphalt Burners
StarJet
StarJet recirculates hot gases to stabilize combustion without a refractory ignition tile or separate combustion chamber.
StarJet recirculates hot gases to stabilize combustion without a refractory ignition tile or separate combustion chamber. The flame can be adjusted from a short drum-mixing shape to a longer profile. Broad turndown supports reduced-production duties, and the listed fuels include oils, natural gas, liquid propane and landfill gas.
Features & Benefits
- Blower Pressure Options
- 24 osig or 36 osig
- Multi‑Fuel Operation
- Any two fuels in combination (except liquid LP and fuel oil together)
- Air Entry Orientation
- 45 deg air entry at 3, 6, 9, or 12 o’clock
- Combustion Principle
- Internal hot‑gas recirculation for flame stability
- Turndown Capability
- Wide turndown ratio (useful for low production rates)
- Primary Application
- Rotary drying (asphalt production)
- Maximum Capacity
- Approximately 12 to 200 MMBTU/hr (model dependent)
- Supported Fuels
- Heavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas
- Product Series
- SJ/SJC
- Burner Design
- Open‑fired, no combustion chamber required
- Product Type
- Open‑fired rotary dryer burner
- Flame Type
- High‑intensity, rapid heat release
- Approvals
- NFPA‑compliant fuel manifolds
- Recirculation stabilizes the flame without a refractory ignition tile.
- Wide turndown supports lower production rates.
Applications
- Drum mixing
- Reduced-production and cold-patch asphalt duties
Overview
- Models
- SJ075 to SJ980
- Product Type
- Open‑fired rotary dryer burner
Pressure Specifications
- Blower Pressure Options
- 24 osig or 36 osig
Fuel, Gas & Media Specifications
- Multi‑Fuel Operation
- Any two fuels in combination (except liquid LP and fuel oil together)
Air & Combustion Air Specifications
- Air Entry Orientation
- 45 deg air entry at 3, 6, 9, or 12 o’clock
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Internal hot‑gas recirculation for flame stability
Processing & Performance Metrics
- Turndown Capability
- Wide turndown ratio (useful for low production rates)
- Maximum Capacity
- Approximately 12 to 200 MMBTU/hr (model dependent)
Applications & Compatibility
- Primary Application
- Rotary drying (asphalt production)
Actuation, Valve & Motion Control Specifications
- Supported Fuels
- Heavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas
Product Overview & Classification
- Product Series
- SJ/SJC
Product Design & Configuration
- Burner Design
- Open‑fired, no combustion chamber required
Ignition, Flame & Supervision Specifications
- Flame Type
- High‑intensity, rapid heat release
Standards & Certifications
- Approvals
- NFPA‑compliant fuel manifolds
| Parameter | Published value / configuration |
|---|---|
| Models | SJ075 to SJ980 |
| Product Type | Open‑fired rotary dryer burner |
| Blower Pressure Options | 24 osig or 36 osig |
| Multi‑Fuel Operation | Any two fuels in combination (except liquid LP and fuel oil together) |
| Air Entry Orientation | 45 deg air entry at 3, 6, 9, or 12 o’clock |
| Combustion Principle | Internal hot‑gas recirculation for flame stability |
| Turndown Capability | Wide turndown ratio (useful for low production rates) |
| Maximum Capacity | Approximately 12 to 200 MMBTU/hr (model dependent) |
| Primary Application | Rotary drying (asphalt production) |
| Supported Fuels | Heavy fuel oil, light fuel oil, natural gas, liquid propane (LP), landfill gas |
| Product Series | SJ/SJC |
| Burner Design | Open‑fired, no combustion chamber required |
| Flame Type | High‑intensity, rapid heat release |
| Approvals | NFPA‑compliant fuel manifolds |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 101029648 | MNFLD ASSY,GAS,SJ200 260,9 & 12 O CLOCK | Request quotation |
| 101029649 | MNFLD ASSY,GAS,SJ200 260,3 & 6 O CLOCK A | Request quotation |
| 101029650 | KIT,SJ4200 4260,GAS VLV MTRG,3 & 6 O CLO | Request quotation |
| 101029651 | KIT,SJ4200 4260,GAS VLV MTRG,9 & 12 O CL | Request quotation |
| 101029710 | KIT,SJ4360 4580,GAS VLV,3 AND 6 OCLOCK B | Request quotation |
| 101029712 | KIT,SJ4360 4580,GAS VLV,9 AND 12 OCLOCK | Request quotation |
| 101029713 | MNFLD, ASY,SJ 360 580 90°,3 AND 6 OCLOCK | Request quotation |
| 101031090 | MNFLD,LP,SJ4520 & 4580,3 AND 6 OCLOCK,W | Request quotation |
| 101031091 | MNFLD,LP,SJ4520 & 4580,9 AND 12 OCLOCK,W | Request quotation |
| 101031350 | MNFLD,ASY,OIL,SJ4360,3 AND 6 OCLOCK | Request quotation |
Manufacturer sources