Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Hauck Asphalt Burners

MegaStar

MegaStar uses variable-frequency airflow control with measured fuel flow for asphalt and sand-drying duties.

MegaStar uses variable-frequency airflow control with measured fuel flow for asphalt and sand-drying duties. It accepts several gas and liquid fuels, with atomization arrangements selected for fuel grade and altitude. Adjustable flame geometry, standard or extended lengths and a compact serviceable package support different drums; BCS7000 provides the associated control option.

Features & Benefits

Primary Application
Rotary drying systems
Main Air Pressure
Model dependent (up to ~18.5 in. wc)
Maximum Capacity
Gas: Up to ~166 MMBTU/hr (45.2 MW), model dependent|Oil: Up to ~153 MMBTU/hr (41.5 MW), model dependent
Supported Fuels
Natural Gas, Vaporous Propane, Liquid Propane (LP), Light Fuel Oil (No. 2), Heavy Fuel Oil (No. 4/5/6), Waste/Recycled Oil
Product Series
MS (MS‑25 to MS‑150)
Mounting Types
Drum centerline, same pitch as drum
Main Air Flow
Model dependent (up to ~1,960,000 scfh)
Burner Design
Total air aggregate drying burner
Product Type
Rotary dryer burner
Approvals
Designed for NFPA‑compliant fuel trains
  • VFD airflow control lowers electrical demand and starting current.
  • Reduced linkage and moving parts simplify maintenance.

Applications

  • Asphalt production
  • Sand drying
  • Warm-mix duties with custom burner length

Detailed capabilities

Airflow control and combustion-zone matching

MegaStar uses a variable-frequency drive to regulate combustion air, combining the airflow response with real-time fuel measurement. Flame shape can be adjusted around the drum's required combustion zone so material does not quench an incompletely burned flame. The manufacturer links this arrangement to reduced NOx, CO and VOC production, while avoiding the implication that every fuel and installation will achieve one fixed emissions result.

Manufacturer reference ↗

Fuel, length and control selections

Light oil and liquid propane use the stated low-pressure atomization arrangement. Heavy oil or high-elevation applications can use compressed-air atomization. Standard and long-nose versions, plus custom lengths for warm-mix duty, address different plant layouts. The compact package reduces mechanical linkages and moving parts, with BCS7000 available for burner/process control. Nominal size groups cover 25–150 million Btu/hr for the published application-temperature limit.

Manufacturer reference ↗

Features and benefits

  • VFD airflow control lowers electrical demand and starting current.
  • Reduced linkage and moving parts simplify maintenance.

Manufacturer reference ↗

Published application context

  • Asphalt production
  • Sand drying
  • Warm-mix duties with custom burner length

Manufacturer reference ↗

Specifications

Overview

Models
MS‑25, MS‑50, MS‑75, MS‑100, MS‑125, MS‑150
Product Type
Rotary dryer burner

Applications & Compatibility

Primary Application
Rotary drying systems

Pressure Specifications

Main Air Pressure
Model dependent (up to ~18.5 in. wc)

Processing & Performance Metrics

Maximum Capacity
Gas: Up to ~166 MMBTU/hr (45.2 MW), model dependent; Oil: Up to ~153 MMBTU/hr (41.5 MW), model dependent

Actuation, Valve & Motion Control Specifications

Supported Fuels
Natural Gas, Vaporous Propane, Liquid Propane (LP), Light Fuel Oil (No. 2), Heavy Fuel Oil (No. 4/5/6), Waste/Recycled Oil

Product Overview & Classification

Product Series
MS (MS‑25 to MS‑150)

Installation & Mounting Specifications

Mounting Types
Drum centerline, same pitch as drum

Air & Combustion Air Specifications

Main Air Flow
Model dependent (up to ~1,960,000 scfh)

Product Design & Configuration

Burner Design
Total air aggregate drying burner

Standards & Certifications

Approvals
Designed for NFPA‑compliant fuel trains
MegaStar — manufacturer page values
ParameterPublished value / configuration
ModelsMS‑25, MS‑50, MS‑75, MS‑100, MS‑125, MS‑150
Product TypeRotary dryer burner
Primary ApplicationRotary drying systems
Main Air PressureModel dependent (up to ~18.5 in. wc)
Maximum CapacityGas: Up to ~166 MMBTU/hr (45.2 MW), model dependent; Oil: Up to ~153 MMBTU/hr (41.5 MW), model dependent
Supported FuelsNatural Gas, Vaporous Propane, Liquid Propane (LP), Light Fuel Oil (No. 2), Heavy Fuel Oil (No. 4/5/6), Waste/Recycled Oil
Product SeriesMS (MS‑25 to MS‑150)
Mounting TypesDrum centerline, same pitch as drum
Main Air FlowModel dependent (up to ~1,960,000 scfh)
Burner DesignTotal air aggregate drying burner
ApprovalsDesigned for NFPA‑compliant fuel trains

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
HK303341IMPLR,AIRFOIL SLD NOSE BLD,CW CHICAGO 22Request quotation
HK303342CONE,MS 50 CHICAGO 2214 W/SCREENRequest quotation
HK303637CONE,MS 125 & 150 INLT CHICAGO 4014 D190Request quotation
HK303638CONE,MS 75 & 100 INLT CHICAGO 3612 D1902Request quotation
HK402649X008-001KIT ASSY,MS50 HVY OIL INS HTR 8Request quotation
HK406788PLT ASSY,MS50 HEATSHIELDRequest quotation
HK406802INS,OIL,MS,MS50Request quotation
HK406803TEE ASSY,MS50 OIL INSRequest quotation
HK406804INS,COMP AIR/OIL,MS,MS50Request quotation
HK406834ATTENUATOR UNIT ASSY,MS50 SOUNDRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/hauck-asphalt-burners/megastar

Last source check: 2026-11-02

MegaStar Primary IMage · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.