Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Hauck Asphalt Burners

NovaStar

NovaStar uses lean premixed combustion for low-NOx gaseous-fuel operation without the cited FGR or water-injection arrangements.

NovaStar uses lean premixed combustion for low-NOx gaseous-fuel operation without the cited FGR or water-injection arrangements. A compact flame completes combustion within the drum's combustion zone. VFD airflow control, modular construction and standard or long-nose versions support stationary and portable plants, with Hauck BCS controls providing process management.

Features & Benefits

Combustion Principle
Premixed air/gas with short compact flame
Primary Application
Aggregate and asphalt rotary drying
Pilot Fuel Pressure
15 to 25 psig
Flame Adjustability
Not adjustable (fixed compact flame)
Maximum Capacity
Up to ~150 MMBTU/hr (model dependent)
Supported Fuels
Natural Gas, Gaseous Propane
Product Series
NS
NOx Emissions
Ultra‑low NOx
Control Panel
Hauck BCS 6000
Burner Design
Lean premix gas burner
Product Type
Ultra‑low NOx rotary dryer gas burner
Control Type
PLC‑based with touchscreen HMI
Flame Type
Short, compact, high‑intensity flame
Approvals
Designed to meet NFPA requirements
  • Lean premixing provides low-NOx gas firing without the cited FGR equipment.
  • A compact modular package supports stationary or portable installations.

Applications

  • Stationary and portable asphalt plants

Detailed capabilities

Lean premixing and compact drum flame

NovaStar's lean-premix design targets very low NOx on natural gas or vaporized propane without FGR or water injection. Completing combustion inside a short zone avoids material-induced flame quenching. VFD airflow control reduces motor demand, and the sealed arrangement limits noise. Standard/extended noses and modular packaging suit the drum and stationary or portable plant, with Hauck BCS providing the control option.

Manufacturer reference ↗

Features and benefits

  • Lean premixing provides low-NOx gas firing without the cited FGR equipment.
  • A compact modular package supports stationary or portable installations.

Manufacturer reference ↗

Published application context

  • Stationary and portable asphalt plants

Manufacturer reference ↗

Specifications

Overview

Models
NS‑75, NS‑100, NS‑125, NS‑150
Product Type
Ultra‑low NOx rotary dryer gas burner

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Premixed air/gas with short compact flame

Applications & Compatibility

Primary Application
Aggregate and asphalt rotary drying

Pressure Specifications

Pilot Fuel Pressure
15 to 25 psig

Ignition, Flame & Supervision Specifications

Flame Adjustability
Not adjustable (fixed compact flame)
Flame Type
Short, compact, high‑intensity flame

Processing & Performance Metrics

Maximum Capacity
Up to ~150 MMBTU/hr (model dependent)
NOx Emissions
Ultra‑low NOx

Actuation, Valve & Motion Control Specifications

Supported Fuels
Natural Gas, Gaseous Propane

Product Overview & Classification

Product Series
NS

Control, Logic & Functional Behavior

Control Panel
Hauck BCS 6000
Control Type
PLC‑based with touchscreen HMI

Product Design & Configuration

Burner Design
Lean premix gas burner

Standards & Certifications

Approvals
Designed to meet NFPA requirements
NovaStar — manufacturer page values
ParameterPublished value / configuration
ModelsNS‑75, NS‑100, NS‑125, NS‑150
Product TypeUltra‑low NOx rotary dryer gas burner
Combustion PrinciplePremixed air/gas with short compact flame
Primary ApplicationAggregate and asphalt rotary drying
Pilot Fuel Pressure15 to 25 psig
Flame AdjustabilityNot adjustable (fixed compact flame)
Flame TypeShort, compact, high‑intensity flame
Maximum CapacityUp to ~150 MMBTU/hr (model dependent)
NOx EmissionsUltra‑low NOx
Supported FuelsNatural Gas, Gaseous Propane
Product SeriesNS
Control PanelHauck BCS 6000
Control TypePLC‑based with touchscreen HMI
Burner DesignLean premix gas burner
ApprovalsDesigned to meet NFPA requirements

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
HK405256TB SUB ASSY,NS100 FRNT FLMRequest quotation
HK405258CONE,NS100 FRNT FLM TBRequest quotation
HK405259CONE ASSY,NS100 FLM AIR HSGRequest quotation
HK405261CONE,NS75&100 REARRequest quotation
HK405263CONE,NS75&100 FLMRequest quotation
HK405265NZL ASSY,NS75&100 BRNRRequest quotation
HK405636CONE,NS75 FRNT FLM TBRequest quotation
HK405639CONE,NS75 REARRequest quotation
HK405641CONE,NS75 FLMRequest quotation
HK405887HEATSHIELD ASSY,NS75Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/hauck-asphalt-burners/novastar

Last source check: 2026-11-02

NovaStar Primary Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry