Honeywell Process Measurement & Control

Industrial Flame Monitoring (IFM)

Signal Processors Model P531 or P532

P531/P532 supports simultaneous monitoring using two S55XBE heads and one S70X head.

P531/P532 supports simultaneous monitoring using two S55XBE heads and one S70X head. A detachable P532UI interface supports configuration and separate UV/IR display where specified. Independent flame relays, automatic setup and selectable configuration files support multi-head applications such as the published tangential-boiler main-burner and igniter arrangement.

Features & Benefits

Design and operation
P531/P532 supports simultaneous monitoring using two S55XBE heads and one S70X head.
  • A shared detachable interface can reduce cost across multiple processors.

Applications

  • Tangentially fired boiler main-burner and igniter monitoring

Detailed capabilities

Different viewing roles within one processor

The P531 arrangement can observe two S55XBE heads plus one S70X head simultaneously. Honeywell describes tangential boiler firing, where two heads cover the main burner and the S70X observes a side or horn igniter. Flame relays are independent but the fault relay is shared. With the specified S550BE/interface combination, UV and IR counts can be displayed separately rather than merged into one reading.

Manufacturer reference ↗

Setup files and detachable operator interface

Programming uses P532UI, FlameTools or the stated optional PDA arrangement. A detachable interface can serve installations where permanently fitting an interface to every processor is unnecessary. Each head has two selectable configuration files; automatic gain, sequencing and filtering support initial setup. Marginal-alarm relays can provide an additional indication as flame count falls. Temperature reporting excludes S70X, and FlameTools PC/HMI network limits differ as explicitly published.

Manufacturer reference ↗

Features and benefits

  • A shared detachable interface can reduce cost across multiple processors.

Manufacturer reference ↗

Published application context

  • Tangentially fired boiler main-burner and igniter monitoring

Manufacturer reference ↗

Part Number

Published part numbers

5 parts

Part NumberDescriptionEnquiry
P531ACAC SIGNAL PROCESSR W.BASE/TRM (3CHNL)Request quotation
P531DCDC SIGNAL PROCESSR W.BASE/TRM (3CHNL)Request quotation
P532ACAC SIGNAL PROCSSR W.BASE/TRM (3CH+DISPL)Request quotation
P532DCDC SIGNAL PROCSSR W.BASE/TRM (3CH+DISPL)Request quotation
P532UIPROGRAMMING UI FOR P531 SIGNAL PROCESSRSRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/industrial-flame-monitoring-ifm/signal-processors-model-p531-or-p532

Last source check: 2026-11-02

Signal Processors Model P531 or P532 Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.