Industrial Flame Monitoring (IFM)
FASA Glass and Quartz Fiber Optics
FASA extends the optical path between a flame and its viewing head where direct sighting or temperature conditions prevent normal mounting.
FASA extends the optical path between a flame and its viewing head where direct sighting or temperature conditions prevent normal mounting. Glass fibers address oil and coal flames; quartz addresses all fuel types. Custom carriers, lenses and purge adapters adapt the assembly to the burner and required viewing angle.
Features & Benefits
- Cooling/Purge Air Option
- 10 SCFM at 10 in WC (0.25 m³/min at 25.4 mm WC)|Oil and moisture-free, < 40 deg C
- Viewing Head Connection
- 1/2 in NPT on viewing head flange (model dependent)
- Transmission Distance
- Up to 25 feet (approximately 8 meters)
- Environmental Rating
- NEMA 4X (IP56), lens end sealed for hazardous locations
- Mounting Dimensions
- 3 in NPT mounting via 3 locking screws|Outer carrier: 3.375 in OD x 9 in long
- Temperature Rating
- -40 to +662 deg F (-40 to +350 deg C)
- Construction
- Corrosion-resistant stainless steel
- Functions
- Extends flame detector viewing capability in hostile or obstructed environments
- Optical extension permits sensing where direct head mounting is impractical.
Applications
- Indirect flame viewing where access or temperature prevents direct head installation
Detailed capabilities
Extending the optical path
The fiber system places the viewing head away from a difficult sighting location while carrying flame radiation to the sensor. This addresses inaccessible geometry, temperatures beyond the head rating or a need to observe closer to the flame. Glass fiber is described for oil/coal monitoring, whereas quartz serves the full stated fuel range. Transmission distance depends on the application, so it is not a universal cable-length rating.
Custom carriers, lenses and connections
An assembly may combine a fiber bundle with inner and outer carriers, using rigid sections, flexible sections or both. Stainless construction and layered protection address heat, vibration and corrosion. The FOLC-SC lens looks straight ahead; FOLC-9C provides the stated nine-degree offset. Purged or unpurged viewing-end adapters and half- or one-inch NPT head connections adapt the assembly. Compatibility includes Honeywell processors and the U2 integrated head arrangement named in the source.
Features and benefits
- Optical extension permits sensing where direct head mounting is impractical.
Published application context
- Indirect flame viewing where access or temperature prevents direct head installation
Air & Combustion Air Specifications
- Cooling/Purge Air Option
- 10 SCFM at 10 in WC (0.25 m³/min at 25.4 mm WC); Oil and moisture-free, < 40 deg C
Connections & Interfaces
- Viewing Head Connection
- 1/2 in NPT on viewing head flange (model dependent)
Inputs, Outputs & Interface Signals
- Transmission Distance
- Up to 25 feet (approximately 8 meters)
Environmental Conditions
- Environmental Rating
- NEMA 4X (IP56), lens end sealed for hazardous locations
Dimensions & Weight
- Mounting Dimensions
- 3 in NPT mounting via 3 locking screws; Outer carrier: 3.375 in OD x 9 in long
Temperature Control/Measurement
- Temperature Rating
- -40 to +662 deg F (-40 to +350 deg C)
Product Overview & Classification
- Construction
- Corrosion-resistant stainless steel
Applications & Compatibility
- Applications
- Tilting burners (±30 deg movement), Low NOx coal burners, Gas and oil-fired turbine generators, Situations with obstructed flame view or high vibration/temperature, Corner-fired units with parallel fuel flow
Control, Logic & Functional Behavior
- Functions
- Extends flame detector viewing capability in hostile or obstructed environments
| Parameter | Published value / configuration |
|---|---|
| Cooling/Purge Air Option | 10 SCFM at 10 in WC (0.25 m³/min at 25.4 mm WC); Oil and moisture-free, < 40 deg C |
| Viewing Head Connection | 1/2 in NPT on viewing head flange (model dependent) |
| Transmission Distance | Up to 25 feet (approximately 8 meters) |
| Environmental Rating | NEMA 4X (IP56), lens end sealed for hazardous locations |
| Mounting Dimensions | 3 in NPT mounting via 3 locking screws; Outer carrier: 3.375 in OD x 9 in long |
| Temperature Rating | -40 to +662 deg F (-40 to +350 deg C) |
| Construction | Corrosion-resistant stainless steel |
| Applications | Tilting burners (±30 deg movement), Low NOx coal burners, Gas and oil-fired turbine generators, Situations with obstructed flame view or high vibration/temperature, Corner-fired units with parallel fuel flow |
| Functions | Extends flame detector viewing capability in hostile or obstructed environments |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 50107568-001 | FO ADPT BDY LENS | Request quotation |
| FASA | FIBER OPTIC VH EXTENSION ASSEMBLY | Request quotation |
| FASA-INT | FIBER OPTIC INTERNAL EXTENSION ASSEMBLY | Request quotation |
| FOLC-9C | FIBER OPTIC LENS CARTR/COUPLR (9 DEGR) | Request quotation |
| FOLC-HS | .5"NPT CONN FO LENS CART | Request quotation |
| FOLC-SC | FIBER OPTIC LENS CARTR/COUPLR (STRAIGHT) | Request quotation |
| S550FOAD | FIBER OPTICS FOR S55XB/BE | Request quotation |
| S550FOADY-FT | FIBER OPTICS W.AIRPURGE FOR S55XB/BE | Request quotation |
| S592-PC | FIBER ASSY QRTZ LENS FOR S592/S593 | Request quotation |
| S592-PP | PLANO/PLANO WINDOW FOR S592/S593 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
lens1_sml · Manufacturer ownership retained; republication licence not independently confirmed
foad_sml · Manufacturer ownership retained; republication licence not independently confirmed
lens3x_sml · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.