Industrial Flame Monitoring (IFM)
Signal Processors Model P522
P522 supervises two switched S55XBE viewing heads with separate sensor-gain adjustment and selectable infrared flicker settings.
P522 supervises two switched S55XBE viewing heads with separate sensor-gain adjustment and selectable infrared flicker settings. A digital display, LEDs and bar graph show operating status. Configuration can be local or through FlameTools, with two selectable files, an adjustable switching threshold and a scalable analog output.
Features & Benefits
- Flame Failure Response Time (FFRT)
- 1, 2, or 3 seconds
- Safe Failure Fraction (SFF)
- >99%
- Viewing Head Compatibility
- S55XBE series
- Analog Flame Signal Output
- User-selectable 0 to 20 mA or 4 to 20 mA (360 Ohm max)
- Ambient Temperature Range
- 0 to +50 deg C (32 to +122 deg F)
- Self-Check Relay Output
- 1 Form C Contact (SPDT)
- Communication Registers
- 23 Holding Registers (4X) and 5 Discrete Registers (0X) including flame count, gain, UV/IR settings, temperature, relay status, selections, firmware revision. (Modbus)
- Battery Backup Voltage
- +100 mA per additional viewing head|22 to 26 VDC, 300 mA
- Serial Communication
- RS-422, 4800 or 9600 baud, 4-wire/2 twisted pair
- Channel Select Input
- 7.5-30 VDC, 3900 Ohm input resistance
- System Architecture
- 1oo1 (one out of one)
- Remote Meter Output
- 0 to 20 mA or 4 to 20 mA (switchable)
- Proof Test Interval
- 1 to 5 years
- Mounting Dimensions
- 7.2 in H x 4.25 in W x 6.4 in D (approximately)
- Viewing Head Power
- +26 VDC max, fused 0.25 A; +14.3 VDC pulsing (0.2 s ON, 0.8 s OFF)
- IR Filter Settings
- 8 options: 16, 24, 33, 52, 75, 100, 155, 215 Hz
- Flame Signal Input
- 7.5-30 VDC, 3900 Ohm input resistance
- Flame Relay Output
- 2 Form C Contacts (DPDT)
- UV Gain Range
- 0 to 99
- IR Gain Range
- 0 to 699 (default: 450)
- Relay Rating
- Max 60 W, 125 VAC; Max 220 VDC/250 VAC; Max 2 A
- Approvals
- WEEE Directive 2012/19/EU - Electronic waste compliance, CSA Certified (Yes), SIL 3 (Safety Integrity Level), FM Approved
- Independent gain and infrared settings improve application discrimination.
Applications
- High-discrimination flame monitoring with switched S55XBE heads
Overview
- Models
- P522AC, P522DC
Ignition, Flame & Supervision Specifications
- Flame Failure Response Time (FFRT)
- 1, 2, or 3 seconds
- Analog Flame Signal Output
- User-selectable 0 to 20 mA or 4 to 20 mA (360 Ohm max)
- IR Filter Settings
- 8 options: 16, 24, 33, 52, 75, 100, 155, 215 Hz
- Flame Signal Input
- 7.5-30 VDC, 3900 Ohm input resistance
- Flame Relay Output
- 2 Form C Contacts (DPDT)
- UV Gain Range
- 0 to 99
- IR Gain Range
- 0 to 699 (default: 450)
Safety, Protection & Reliability
- Safe Failure Fraction (SFF)
- >99%
Applications & Compatibility
- Viewing Head Compatibility
- S55XBE series
Environmental Conditions
- Ambient Temperature Range
- 0 to +50 deg C (32 to +122 deg F)
Control, Logic & System Behavior
- Self-Check Relay Output
- 1 Form C Contact (SPDT)
Communication & Interfaces
- Communication Registers
- 23 Holding Registers (4X) and 5 Discrete Registers (0X) including flame count, gain, UV/IR settings, temperature, relay status, selections, firmware revision. (Modbus)
- Serial Communication
- RS-422, 4800 or 9600 baud, 4-wire/2 twisted pair
Electrical Specifications
- Battery Backup Voltage
- +100 mA per additional viewing head; 22 to 26 VDC, 300 mA
- Proof Test Interval
- 1 to 5 years
- Viewing Head Power
- +26 VDC max, fused 0.25 A; +14.3 VDC pulsing (0.2 s ON, 0.8 s OFF)
Inputs, Outputs & Signal Interfaces
- Channel Select Input
- 7.5-30 VDC, 3900 Ohm input resistance
- Relay Rating
- Max 60 W, 125 VAC; Max 220 VDC/250 VAC; Max 2 A
Actuation, Valve & Motion Control Specifications
- System Architecture
- 1oo1 (one out of one)
Inputs, Outputs & Interface Signals
- Remote Meter Output
- 0 to 20 mA or 4 to 20 mA (switchable)
Dimensions & Weight
- Mounting Dimensions
- 7.2 in H x 4.25 in W x 6.4 in D (approximately)
Standards & Certifications
- Approvals
- WEEE Directive 2012/19/EU - Electronic waste compliance, CSA Certified (Yes), SIL 3 (Safety Integrity Level), FM Approved
| Parameter | Published value / configuration |
|---|---|
| Models | P522AC, P522DC |
| Flame Failure Response Time (FFRT) | 1, 2, or 3 seconds |
| Analog Flame Signal Output | User-selectable 0 to 20 mA or 4 to 20 mA (360 Ohm max) |
| IR Filter Settings | 8 options: 16, 24, 33, 52, 75, 100, 155, 215 Hz |
| Flame Signal Input | 7.5-30 VDC, 3900 Ohm input resistance |
| Flame Relay Output | 2 Form C Contacts (DPDT) |
| UV Gain Range | 0 to 99 |
| IR Gain Range | 0 to 699 (default: 450) |
| Safe Failure Fraction (SFF) | >99% |
| Viewing Head Compatibility | S55XBE series |
| Ambient Temperature Range | 0 to +50 deg C (32 to +122 deg F) |
| Self-Check Relay Output | 1 Form C Contact (SPDT) |
| Communication Registers | 23 Holding Registers (4X) and 5 Discrete Registers (0X) including flame count, gain, UV/IR settings, temperature, relay status, selections, firmware revision. (Modbus) |
| Serial Communication | RS-422, 4800 or 9600 baud, 4-wire/2 twisted pair |
| Battery Backup Voltage | +100 mA per additional viewing head; 22 to 26 VDC, 300 mA |
| Proof Test Interval | 1 to 5 years |
| Viewing Head Power | +26 VDC max, fused 0.25 A; +14.3 VDC pulsing (0.2 s ON, 0.8 s OFF) |
| Channel Select Input | 7.5-30 VDC, 3900 Ohm input resistance |
| Relay Rating | Max 60 W, 125 VAC; Max 220 VDC/250 VAC; Max 2 A |
| System Architecture | 1oo1 (one out of one) |
| Remote Meter Output | 0 to 20 mA or 4 to 20 mA (switchable) |
| Mounting Dimensions | 7.2 in H x 4.25 in W x 6.4 in D (approximately) |
| Approvals | WEEE Directive 2012/19/EU - Electronic waste compliance, CSA Certified (Yes), SIL 3 (Safety Integrity Level), FM Approved |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| P522AC | AC SERIES 500 PROCESSOR UNIT (2CHNL) | Request quotation |
| P522DC | DC SERIES 500 PROCESSOR UNIT (2CHNL) | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Model P522 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.