Controllers
Experion® Process, Machinery and Drives (PMD) - FCE Controller
Experion PMD FCE combines process, machinery and drive-control capabilities with fieldbus integration.
Experion PMD FCE combines process, machinery and drive-control capabilities with fieldbus integration. Published arrangements include Profibus or Profinet interfaces and connections for legacy TotalPlant Alcont I/O, supporting migration of an installed system. Heat-pipe cooling avoids fans, while channel diagnostics and alarms are presented consistently through the automation system for operators and maintenance teams.
Features & Benefits
- Cooling
- Heat pipe
- Integration
- Fieldbus and TotalPlant Alcont I/O links
- Supports migration and centralized diagnostics
Applications
- Pulp and paper
- Metals
- Chemicals
- Pharmaceuticals
- Food and beverage
Detailed capabilities
Product and configuration
Experion PMD FCE combines process, machinery and drive-control capabilities with fieldbus integration. Published arrangements include Profibus or Profinet interfaces and connections for legacy TotalPlant Alcont I/O, supporting migration of an installed system. Heat-pipe cooling avoids fans, while channel diagnostics and alarms are presented consistently through the automation system for operators and maintenance teams.
- Cooling: Heat pipe
- Integration: Fieldbus and TotalPlant Alcont I/O links
Operation and integration
The updated FCE connects plant Ethernet with fieldbus and legacy TotalPlant Alcont I/O extension racks. Heat-pipe cooling avoids fans, while channel status and diagnostics enter the system's common alarm and display mechanisms. The newer PMD narrative describes Profibus or Profinet interfaces and migration toward Experion PKS capabilities.
Application and selection
It provides a modernization route for TPA installations while retaining application and graphics investments through conversion. Updated controllers and Experion features address obsolescence, spare-part uncertainty and lifecycle support. Interface availability must follow the relevant release rather than assuming all FCE generations have identical fieldbus support.
Others
- Environmental Classification
- G2 (Gas, Corrosion); IEC 60721-3-3 Class IE33
- Application Memory Space
- 16 MB
- Calendar Clock Accuracy
- 0.5 s/day
- Power Supply Connector
- 3-Pin Screw-Locked
- Fieldbus Changeability
- Profibus interfaces removable via front panel
- Operating Temperature
- +5 to +40°C
- System Net Interface
- 10/100/1000 Mbit/s; 2X RJ45; Ethernet FTE A & B
- Redundancy Interface
- 10/100/1000 Mbit/s; 1X RJ45; Ethernet
- Profibus Interfaces
- 9-Pin D-Connector (Female); EN 50170; Max 2; RS485
- Non-Volatile Memory
- Compact Flash >1 GB
- Operating Voltage
- 24 V ±10% volt
- Controller Models
- PD-CFFCE22: With Profibus Interface; PD-CFFCE31: With Profinet Interface
- UPLINE Interface
- 1, 2, 4 Mbit/s; 75 Ω Transmission; BNC Connectors
- Indicator Lights
- Green (Communication); Yellow (1000 Mbit/s Bus Rate)
- Heat Dissipation
- < 36 W
- Function Display
- 128 x 64 pixel LCD
- Cabinet Capacity
- Up to 20 Controllers/Cabinet
- Controller Type
- FC (Field Controller); FCE (Field Controller Express)
- Mounting Shelf
- 19 in Wide; 2U High; Holds Two Controllers
- Reset Options
- Cold Boot (>4 sec); Warm Boot (1 to 4 sec)
- EMC Standards
- EN61000-6-2:2005 (Immunity); EN61000-6-4:2007 (Emissions)
- Push Buttons
- 3 under the display for menu control
- Power Switch
- Separate Switch beside Connector
- I/O Capacity
- 4999 I/O Channels per FCE-PN Controller
- Dimensions
- 220 x 68 x 220 mm
- Standards
- EN50170, DP/VO V1, V2, Class 1 and 2 Master
- Processor
- Intel Celeron 1.06 GHz or Equivalent
- IP Rating
- IP43
- LCD Type
- 128 x 64 Pixel Graphics LCD; FSTN Technique; LED Backlight
| Parameter | Published value / configuration |
|---|---|
| Environmental Classification | G2 (Gas, Corrosion); IEC 60721-3-3 Class IE33 |
| Application Memory Space | 16 MB |
| Calendar Clock Accuracy | 0.5 s/day |
| Power Supply Connector | 3-Pin Screw-Locked |
| Fieldbus Changeability | Profibus interfaces removable via front panel |
| Operating Temperature | +5 to +40°C |
| System Net Interface | 10/100/1000 Mbit/s; 2X RJ45; Ethernet FTE A & B |
| Redundancy Interface | 10/100/1000 Mbit/s; 1X RJ45; Ethernet |
| Profibus Interfaces | 9-Pin D-Connector (Female); EN 50170; Max 2; RS485 |
| Non-Volatile Memory | Compact Flash >1 GB |
| Operating Voltage | 24 V ±10% volt |
| Controller Models | PD-CFFCE22: With Profibus Interface; PD-CFFCE31: With Profinet Interface |
| UPLINE Interface | 1, 2, 4 Mbit/s; 75 Ω Transmission; BNC Connectors |
| Indicator Lights | Green (Communication); Yellow (1000 Mbit/s Bus Rate) |
| Heat Dissipation | < 36 W |
| Function Display | 128 x 64 pixel LCD |
| Cabinet Capacity | Up to 20 Controllers/Cabinet |
| Controller Type | FC (Field Controller); FCE (Field Controller Express) |
| Mounting Shelf | 19 in Wide; 2U High; Holds Two Controllers |
| Reset Options | Cold Boot (>4 sec); Warm Boot (1 to 4 sec) |
| EMC Standards | EN61000-6-2:2005 (Immunity); EN61000-6-4:2007 (Emissions) |
| Push Buttons | 3 under the display for menu control |
| Power Switch | Separate Switch beside Connector |
| I/O Capacity | 4999 I/O Channels per FCE-PN Controller |
| Dimensions | 220 x 68 x 220 mm |
| Standards | EN50170, DP/VO V1, V2, Class 1 and 2 Master |
| Processor | Intel Celeron 1.06 GHz or Equivalent |
| IP Rating | IP43 |
| LCD Type | 128 x 64 Pixel Graphics LCD; FSTN Technique; LED Backlight |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
Last source check: 2026-11-02
FCE Controller Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.