Portable Gauging
HERMetic UTImeter Rtex for Restricted Operation
UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions.
UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions. It connects to a HERMetic vapor-control valve and provides interchangeable adaptors, tape protection and accessible battery replacement. Stored RTD characteristics support replacement of the sensor or tape without recalibrating the measurement system, simplifying routine cargo-monitoring maintenance.
Features & Benefits
- Measurements
- Ullage, temperature and oil-water interface
- Allows sensor or tape changes without recalibration
Applications
- Restricted marine cargo gauging
- Custody transfer
- Free-water detection
Detailed capabilities
Product and configuration
UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions. It connects to a HERMetic vapor-control valve and provides interchangeable adaptors, tape protection and accessible battery replacement. Stored RTD characteristics support replacement of the sensor or tape without recalibrating the measurement system, simplifying routine cargo-monitoring maintenance.
- Measurements: Ullage, temperature and oil-water interface
Operation and integration
Rtex attaches to a compatible tank vapor-control valve for the source's restricted operating method. It combines ullage and interface detection with continuous RTD temperature readings; factory-stored sensor characteristics mean a tape or sensor change does not require system recalibration. Interchangeable valve adaptors, accessible batteries and tape-cleaning/protection parts support ongoing portable measurement.
Application and selection
The purpose is petroleum-cargo verification, custody measurement and free-water detection under restricted conditions. The manufacturer's historical IMO, ISO, API and approval references describe the documented equipment, not a blanket authorization for closed operation. This restricted instrument must remain distinct from the gas-tight Gtex family when selecting the allowed shipboard method.
Software & Interface
- Display
- LCD, 8 Characters, Backlit
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D, T4 Class I, Zone 0, AEx ia IIB T4/IECEx Zone 0 Ex ia IIB T4
- Approvals
- API MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards
Processing & Performance Metrics
- Ullage/Interface Accuracy
- ±2 mm (±0.08 in)
- Temperature Accuracy
- ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
- Temperature Units
- deg C or deg F selectable
- Tape Accuracy
- ±1.5 mm/30 m (±1/16 in/100 ft)
Technical Specifications
- Temperature Resolution
- 0.01 or 0.1 deg selectable
- Tape Resolution
- 1 mm/1/16 in
Environmental Conditions
- Temperature Range
- Sensor: -40 to 90 deg C (-40 to 194 deg F)
Overview
- Special Features
- Modular design, easy tape/sensor replacement, low maintenance, audible/visible indication, suitable for restricted gauging Millimeter-PRD
I/O Capabilities
- Tape Graduation
- Metric/English
- Indication
- Audible and Visible
Applications & Compatibility
- Typical Uses
- Custody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems
- Applications
- Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks
Electrical Specifications
- Power Supply
- Approved 9V Batteries
Network & Connectivity Infrastructure
- Tape Length
- 15, 30, 35 m (50, 100, 115 ft)
Others
- Maximum Tank Overpressure
- 0.3 bar; 4.4 psi
- Ambient Temperature Range
- -20 to 50 deg C; -4 to 122 deg F
| Parameter | Published value / configuration |
|---|---|
| Display | LCD, 8 Characters, Backlit |
| Hazardous Location Approvals | ATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D, T4 Class I, Zone 0, AEx ia IIB T4/IECEx Zone 0 Ex ia IIB T4 |
| Approvals | API MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards |
| Ullage/Interface Accuracy | ±2 mm (±0.08 in) |
| Temperature Accuracy | ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F) |
| Temperature Units | deg C or deg F selectable |
| Tape Accuracy | ±1.5 mm/30 m (±1/16 in/100 ft) |
| Temperature Resolution | 0.01 or 0.1 deg selectable |
| Tape Resolution | 1 mm/1/16 in |
| Temperature Range | Sensor: -40 to 90 deg C (-40 to 194 deg F) |
| Special Features | Modular design, easy tape/sensor replacement, low maintenance, audible/visible indication, suitable for restricted gauging Millimeter-PRD |
| Tape Graduation | Metric/English |
| Indication | Audible and Visible |
| Typical Uses | Custody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems |
| Applications | Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks |
| Power Supply | Approved 9V Batteries |
| Tape Length | 15, 30, 35 m (50, 100, 115 ft) |
| Maximum Tank Overpressure | 0.3 bar; 4.4 psi |
| Ambient Temperature Range | -20 to 50 deg C; -4 to 122 deg F |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
3 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 11268 | Frame Rtex | Request quotation |
| TS 20048 | Bottle 0.43 l. | Request quotation |
| TS 20049 | Seat | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic UTImeter Rtex for Restricted Operation image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Rtex for Restricted Operation image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.