Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Gauging

HERMetic UTImeter Rtex for Restricted Operation

UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions.

UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions. It connects to a HERMetic vapor-control valve and provides interchangeable adaptors, tape protection and accessible battery replacement. Stored RTD characteristics support replacement of the sensor or tape without recalibrating the measurement system, simplifying routine cargo-monitoring maintenance.

Features & Benefits

Measurements
Ullage, temperature and oil-water interface
  • Allows sensor or tape changes without recalibration

Applications

  • Restricted marine cargo gauging
  • Custody transfer
  • Free-water detection

Detailed capabilities

Product and configuration

UTImeter Rtex measures ullage, temperature and oil-water interface for petroleum cargoes under restricted operating conditions. It connects to a HERMetic vapor-control valve and provides interchangeable adaptors, tape protection and accessible battery replacement. Stored RTD characteristics support replacement of the sensor or tape without recalibrating the measurement system, simplifying routine cargo-monitoring maintenance.

  • Measurements: Ullage, temperature and oil-water interface

Manufacturer reference ↗

Operation and integration

Rtex attaches to a compatible tank vapor-control valve for the source's restricted operating method. It combines ullage and interface detection with continuous RTD temperature readings; factory-stored sensor characteristics mean a tape or sensor change does not require system recalibration. Interchangeable valve adaptors, accessible batteries and tape-cleaning/protection parts support ongoing portable measurement.

Manufacturer reference ↗

Application and selection

The purpose is petroleum-cargo verification, custody measurement and free-water detection under restricted conditions. The manufacturer's historical IMO, ISO, API and approval references describe the documented equipment, not a blanket authorization for closed operation. This restricted instrument must remain distinct from the gas-tight Gtex family when selecting the allowed shipboard method.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Product Catalog - Honeywell Tanksystem for Marine Applications

View resource ↗
Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Software & Interface

Display
LCD, 8 Characters, Backlit

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D, T4 Class I, Zone 0, AEx ia IIB T4/IECEx Zone 0 Ex ia IIB T4
Approvals
API MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards

Processing & Performance Metrics

Ullage/Interface Accuracy
±2 mm (±0.08 in)
Temperature Accuracy
±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
Temperature Units
deg C or deg F selectable
Tape Accuracy
±1.5 mm/30 m (±1/16 in/100 ft)

Technical Specifications

Temperature Resolution
0.01 or 0.1 deg selectable
Tape Resolution
1 mm/1/16 in

Environmental Conditions

Temperature Range
Sensor: -40 to 90 deg C (-40 to 194 deg F)

Overview

Special Features
Modular design, easy tape/sensor replacement, low maintenance, audible/visible indication, suitable for restricted gauging Millimeter-PRD

I/O Capabilities

Tape Graduation
Metric/English
Indication
Audible and Visible

Applications & Compatibility

Typical Uses
Custody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems
Applications
Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks

Electrical Specifications

Power Supply
Approved 9V Batteries

Network & Connectivity Infrastructure

Tape Length
15, 30, 35 m (50, 100, 115 ft)

Others

Maximum Tank Overpressure
0.3 bar; 4.4 psi
Ambient Temperature Range
-20 to 50 deg C; -4 to 122 deg F
HERMetic UTImeter Rtex for Restricted Operation — manufacturer page values
ParameterPublished value / configuration
DisplayLCD, 8 Characters, Backlit
Hazardous Location ApprovalsATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D, T4 Class I, Zone 0, AEx ia IIB T4/IECEx Zone 0 Ex ia IIB T4
ApprovalsAPI MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards
Ullage/Interface Accuracy±2 mm (±0.08 in)
Temperature Accuracy±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
Temperature Unitsdeg C or deg F selectable
Tape Accuracy±1.5 mm/30 m (±1/16 in/100 ft)
Temperature Resolution0.01 or 0.1 deg selectable
Tape Resolution1 mm/1/16 in
Temperature RangeSensor: -40 to 90 deg C (-40 to 194 deg F)
Special FeaturesModular design, easy tape/sensor replacement, low maintenance, audible/visible indication, suitable for restricted gauging Millimeter-PRD
Tape GraduationMetric/English
IndicationAudible and Visible
Typical UsesCustody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems
ApplicationsPortable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks
Power SupplyApproved 9V Batteries
Tape Length15, 30, 35 m (50, 100, 115 ft)
Maximum Tank Overpressure0.3 bar; 4.4 psi
Ambient Temperature Range-20 to 50 deg C; -4 to 122 deg F

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

3 parts

Part NumberDescriptionEnquiry
TS 11268Frame RtexRequest quotation
TS 20048Bottle 0.43 l.Request quotation
TS 20049SeatRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/portable-gauging/hermetic-utimeter-rtex-for-restricted-operation

Last source check: 2026-11-02

HERMetic UTImeter Rtex for Restricted Operation image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic UTImeter Rtex for Restricted Operation image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.