Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Gauging

HERMetic UTImeter Gtex N Series for Closed Operation

The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface.

The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface. Hydrocarbon, chemical and viscosity-oriented versions differ in seals and probe loading, allowing selection for the cargo. The system includes tape-cleaning and protection components and can use interchangeable valve adaptors, supporting repeated onboard measurements while containing tank vapors.

Features & Benefits

Versions
Standard, Chem, Visc and Chem Visc
  • Enables three tank checks in one operation

Applications

  • Marine closed cargo gauging and custody transfer

Detailed capabilities

Product and configuration

The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface. Hydrocarbon, chemical and viscosity-oriented versions differ in seals and probe loading, allowing selection for the cargo. The system includes tape-cleaning and protection components and can use interchangeable valve adaptors, supporting repeated onboard measurements while containing tank vapors.

  • Versions: Standard, Chem, Visc and Chem Visc

Manufacturer reference ↗

Operation and integration

Gtex N stores its temperature-sensor characteristics within the sensing assembly, preserving calibration when the tape or sensor is replaced. The standard, Chem, Visc and Chem Visc arrangements differ in seals, tape connector and probe loading. The one-inch sensing probe can carry the published two-inch load for viscous products, while a window wiper, tape cleaner and protection components support repeated closed measurements.

Manufacturer reference ↗

Application and selection

This N-series page covers marine hydrocarbon or chemical gauging, free-water/interface checks and temperature verification. Use the Chem and viscosity-oriented arrangements only as specified for the medium. The source includes historical standards and certificate listings; they do not establish unrestricted approval for every current cargo or an interchangeable configuration with older Gtex versions.

Manufacturer reference ↗

Case studies & further resources

Specifications

Processing & Performance Metrics

Ullage/Interface Accuracy
±2 mm (±0.08 in)
Temperature Units
deg C or deg F selectable
Temperature Accuracy
±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
Tape Accuracy
±1.5 mm/30 m (±1/16 in/100 ft)

Technical Specifications

Temperature Resolution
0.01 or 0.1 deg selectable
Tape Resolution
1 mm/1/16 in

Environmental Conditions

Temperature Range
Sensor: -40 to 90 deg C (-40 to 194 deg F)

Network & Connectivity Infrastructure

Tape Length
15, 25, 35, 50, 55, 60 m

I/O Capabilities

Tape Graduation
Metric/English
Indication
Audible and Visible

Electrical Specifications

Power Supply
Approved 9V Batteries

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G Ex ia IIC T4 Ga/IECEx Ex ia IIC T4 Ga/FM Class I, Div 1, GP A, B, C & D, T4, Class I, Zone 0, AEx ia IIC T4
Approvals
API MPMS Chap 3.1A, ISO 4512, ISO 4268, IP PMM Part IV, IMO Solas 74, MARPOL 73/78

Software & Interface

Display
LCD, 8 Characters, Backlit

Applications & Compatibility

Applications
Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks

Others

Ambient Temperature Range
-20 to 50 deg C; -4 to 122 deg F
Maximum Tank Overpressure
0.3 bar; 4.4 psi
HERMetic UTImeter Gtex N Series for Closed Operation — manufacturer page values
ParameterPublished value / configuration
Ullage/Interface Accuracy±2 mm (±0.08 in)
Temperature Unitsdeg C or deg F selectable
Temperature Accuracy±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
Tape Accuracy±1.5 mm/30 m (±1/16 in/100 ft)
Temperature Resolution0.01 or 0.1 deg selectable
Tape Resolution1 mm/1/16 in
Temperature RangeSensor: -40 to 90 deg C (-40 to 194 deg F)
Tape Length15, 25, 35, 50, 55, 60 m
Tape GraduationMetric/English
IndicationAudible and Visible
Power SupplyApproved 9V Batteries
Hazardous Location ApprovalsATEX II 1 G Ex ia IIC T4 Ga/IECEx Ex ia IIC T4 Ga/FM Class I, Div 1, GP A, B, C & D, T4, Class I, Zone 0, AEx ia IIC T4
ApprovalsAPI MPMS Chap 3.1A, ISO 4512, ISO 4268, IP PMM Part IV, IMO Solas 74, MARPOL 73/78
DisplayLCD, 8 Characters, Backlit
ApplicationsPortable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks
Ambient Temperature Range-20 to 50 deg C; -4 to 122 deg F
Maximum Tank Overpressure0.3 bar; 4.4 psi

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
TS 10250TAPE 15M IIB STAND. ASSY OTEX NRequest quotation
TS 10251TAPE 25M IIB STAND. ASSY OTEX NRequest quotation
TS 10252TAPE 35M IIB STAND. ASSY OTEX NRequest quotation
TS 10253TAPE 15M IIB CHEM. ASSY OTEX NRequest quotation
TS 10254TAPE 25M IIB CHEM. ASSY OTEX NRequest quotation
TS 10255TAPE 35M IIB CHEM. ASSY OTEX NRequest quotation
TS 10256TAPE 15M IIB CHEM. ASSY GTEX NRequest quotation
TS 10257TAPE 25M IIB CHEM. ASSY GTEX NRequest quotation
TS 10258TAPE 35M IIB CHEM. ASSY GTEX NRequest quotation
TS 11053KnobRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/portable-gauging/hermetic-utimeter-gtex-n-series-for-closed-operation

Last source check: 2026-11-02

HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.