Portable Gauging
HERMetic UTImeter Gtex N Series for Closed Operation
The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface.
The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface. Hydrocarbon, chemical and viscosity-oriented versions differ in seals and probe loading, allowing selection for the cargo. The system includes tape-cleaning and protection components and can use interchangeable valve adaptors, supporting repeated onboard measurements while containing tank vapors.
Features & Benefits
- Versions
- Standard, Chem, Visc and Chem Visc
- Enables three tank checks in one operation
Applications
- Marine closed cargo gauging and custody transfer
Detailed capabilities
Product and configuration
The Gtex N Series provides portable closed gauging of tank ullage, liquid temperature and oil-water interface. Hydrocarbon, chemical and viscosity-oriented versions differ in seals and probe loading, allowing selection for the cargo. The system includes tape-cleaning and protection components and can use interchangeable valve adaptors, supporting repeated onboard measurements while containing tank vapors.
- Versions: Standard, Chem, Visc and Chem Visc
Operation and integration
Gtex N stores its temperature-sensor characteristics within the sensing assembly, preserving calibration when the tape or sensor is replaced. The standard, Chem, Visc and Chem Visc arrangements differ in seals, tape connector and probe loading. The one-inch sensing probe can carry the published two-inch load for viscous products, while a window wiper, tape cleaner and protection components support repeated closed measurements.
Application and selection
This N-series page covers marine hydrocarbon or chemical gauging, free-water/interface checks and temperature verification. Use the Chem and viscosity-oriented arrangements only as specified for the medium. The source includes historical standards and certificate listings; they do not establish unrestricted approval for every current cargo or an interchangeable configuration with older Gtex versions.
Processing & Performance Metrics
- Ullage/Interface Accuracy
- ±2 mm (±0.08 in)
- Temperature Units
- deg C or deg F selectable
- Temperature Accuracy
- ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
- Tape Accuracy
- ±1.5 mm/30 m (±1/16 in/100 ft)
Technical Specifications
- Temperature Resolution
- 0.01 or 0.1 deg selectable
- Tape Resolution
- 1 mm/1/16 in
Environmental Conditions
- Temperature Range
- Sensor: -40 to 90 deg C (-40 to 194 deg F)
Network & Connectivity Infrastructure
- Tape Length
- 15, 25, 35, 50, 55, 60 m
I/O Capabilities
- Tape Graduation
- Metric/English
- Indication
- Audible and Visible
Electrical Specifications
- Power Supply
- Approved 9V Batteries
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G Ex ia IIC T4 Ga/IECEx Ex ia IIC T4 Ga/FM Class I, Div 1, GP A, B, C & D, T4, Class I, Zone 0, AEx ia IIC T4
- Approvals
- API MPMS Chap 3.1A, ISO 4512, ISO 4268, IP PMM Part IV, IMO Solas 74, MARPOL 73/78
Software & Interface
- Display
- LCD, 8 Characters, Backlit
Applications & Compatibility
- Applications
- Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks
Others
- Ambient Temperature Range
- -20 to 50 deg C; -4 to 122 deg F
- Maximum Tank Overpressure
- 0.3 bar; 4.4 psi
| Parameter | Published value / configuration |
|---|---|
| Ullage/Interface Accuracy | ±2 mm (±0.08 in) |
| Temperature Units | deg C or deg F selectable |
| Temperature Accuracy | ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F) |
| Tape Accuracy | ±1.5 mm/30 m (±1/16 in/100 ft) |
| Temperature Resolution | 0.01 or 0.1 deg selectable |
| Tape Resolution | 1 mm/1/16 in |
| Temperature Range | Sensor: -40 to 90 deg C (-40 to 194 deg F) |
| Tape Length | 15, 25, 35, 50, 55, 60 m |
| Tape Graduation | Metric/English |
| Indication | Audible and Visible |
| Power Supply | Approved 9V Batteries |
| Hazardous Location Approvals | ATEX II 1 G Ex ia IIC T4 Ga/IECEx Ex ia IIC T4 Ga/FM Class I, Div 1, GP A, B, C & D, T4, Class I, Zone 0, AEx ia IIC T4 |
| Approvals | API MPMS Chap 3.1A, ISO 4512, ISO 4268, IP PMM Part IV, IMO Solas 74, MARPOL 73/78 |
| Display | LCD, 8 Characters, Backlit |
| Applications | Portable restricted gauging of ullage, temperature, oil‑water interface of petroleum products on marine vessels and shore tanks |
| Ambient Temperature Range | -20 to 50 deg C; -4 to 122 deg F |
| Maximum Tank Overpressure | 0.3 bar; 4.4 psi |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 10250 | TAPE 15M IIB STAND. ASSY OTEX N | Request quotation |
| TS 10251 | TAPE 25M IIB STAND. ASSY OTEX N | Request quotation |
| TS 10252 | TAPE 35M IIB STAND. ASSY OTEX N | Request quotation |
| TS 10253 | TAPE 15M IIB CHEM. ASSY OTEX N | Request quotation |
| TS 10254 | TAPE 25M IIB CHEM. ASSY OTEX N | Request quotation |
| TS 10255 | TAPE 35M IIB CHEM. ASSY OTEX N | Request quotation |
| TS 10256 | TAPE 15M IIB CHEM. ASSY GTEX N | Request quotation |
| TS 10257 | TAPE 25M IIB CHEM. ASSY GTEX N | Request quotation |
| TS 10258 | TAPE 35M IIB CHEM. ASSY GTEX N | Request quotation |
| TS 11053 | Knob | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.