Portable Gauging
HERMetic UTImeter Gtex for Closed Operation
HERMetic UTImeter Gtex performs ullage, temperature and oil-water interface measurements through a gas-tight connection.
HERMetic UTImeter Gtex performs ullage, temperature and oil-water interface measurements through a gas-tight connection. The portable gauge serves hydrocarbons and chemicals, with gasket and weighted-probe choices for corrosive or viscous liquids. Interchangeable adaptors support different vapor-control valves, while factory sensor calibration and replaceable components assist ongoing cargo checks and custody-transfer work.
Features & Benefits
- Measurements
- Ullage, temperature and oil-water interface
- Supports gas-tight tank measurements
Applications
- Marine cargo control
- Custody transfer
- Free-water detection
Detailed capabilities
Product and configuration
HERMetic UTImeter Gtex performs ullage, temperature and oil-water interface measurements through a gas-tight connection. The portable gauge serves hydrocarbons and chemicals, with gasket and weighted-probe choices for corrosive or viscous liquids. Interchangeable adaptors support different vapor-control valves, while factory sensor calibration and replaceable components assist ongoing cargo checks and custody-transfer work.
- Measurements: Ullage, temperature and oil-water interface
Operation and integration
A factory-calibrated sensing assembly stores the RTD characteristics and sends temperature values to the electronics, so replacement of the tape or sensor does not require a new system calibration. Standard Gtex uses FKM sealing for the stated hydrocarbon duties; Chem uses FFKM and its associated connector for corrosive liquids. Visc versions add a two-inch sensing-probe load for viscous cargo, with cleaning and protection parts supplied as described.
Application and selection
The source identifies static level verification, continuous temperature indication and oil-water interface detection for marine cargo and custody work. Its listed IMO, ISO, API and approval references belong to the published product configurations and include historical directives; the applicable certificate and cargo compatibility must follow the selected version rather than the family name alone.
Software & Interface
- Display
- LCD, 8 Characters, Backlit
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D T4/Class I, Zone 0 Ex ia IIB T4/Zone 0, Ex ia IIB T4
- Approvals
- API MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards
Processing & Performance Metrics
- Ullage/Interface Accuracy
- ±2 mm (±0.08 in)
- Temperature Accuracy
- ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
- Temperature Units
- deg C or deg F selectable
- Tape Accuracy
- ±1.5 mm/30 m (±1/16 in/100 ft)
Technical Specifications
- Temperature Resolution
- 0.01 or 0.1 deg selectable
- Tape Resolution
- 1 mm/1/16 in
Environmental Conditions
- Temperature Range
- Sensor: -40 to 90 deg C (-40 to 194 deg F)
Overview
- Special Features
- Continuous Temperature Reading, High Accuracy, Chemically Resistant (Chem Version), Modular Design, Easy Maintenance, Tape Cleaning Device, Window Wiper, Interchangeable Adapters, Tape protection sleeve. Millimeter-PRD
I/O Capabilities
- Tape Graduation
- Metric/English
- Indication
- Audible and Visible
Applications & Compatibility
- Typical Uses
- Custody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems
- Applications
- Portable, gas‑tight gauging of ullage, temperature, oil‑water interface for hydrocarbons and chemicals on marine vessels and shore tanks
Electrical Specifications
- Power Supply
- Approved 9V Batteries
Network & Connectivity Infrastructure
- Tape Length
- 15, 30, 35 m (50, 100, 115 ft)
Others
- Maximum Tank Overpressure
- 0.3 bar; 4.4 psi
- Ambient Temperature Range
- -20 to 50 deg C; -4 to 122 deg F
| Parameter | Published value / configuration |
|---|---|
| Display | LCD, 8 Characters, Backlit |
| Hazardous Location Approvals | ATEX II 1 G Ex ia IIB T4/FM Class I, Div 1, C&D T4/Class I, Zone 0 Ex ia IIB T4/Zone 0, Ex ia IIB T4 |
| Approvals | API MPMS Chap 3.1A, ISO 4512, API MPMS Chap 7, ISO 4268, IP PMM Part IV, IMO, SOLAS, MARPOL, OCIMF Standards |
| Ullage/Interface Accuracy | ±2 mm (±0.08 in) |
| Temperature Accuracy | ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F) |
| Temperature Units | deg C or deg F selectable |
| Tape Accuracy | ±1.5 mm/30 m (±1/16 in/100 ft) |
| Temperature Resolution | 0.01 or 0.1 deg selectable |
| Tape Resolution | 1 mm/1/16 in |
| Temperature Range | Sensor: -40 to 90 deg C (-40 to 194 deg F) |
| Special Features | Continuous Temperature Reading, High Accuracy, Chemically Resistant (Chem Version), Modular Design, Easy Maintenance, Tape Cleaning Device, Window Wiper, Interchangeable Adapters, Tape protection sleeve. Millimeter-PRD |
| Tape Graduation | Metric/English |
| Indication | Audible and Visible |
| Typical Uses | Custody Transfer, Inventory Control, Free Water Detection, Calibration/Verification of Automatic Gauging Systems |
| Applications | Portable, gas‑tight gauging of ullage, temperature, oil‑water interface for hydrocarbons and chemicals on marine vessels and shore tanks |
| Power Supply | Approved 9V Batteries |
| Tape Length | 15, 30, 35 m (50, 100, 115 ft) |
| Maximum Tank Overpressure | 0.3 bar; 4.4 psi |
| Ambient Temperature Range | -20 to 50 deg C; -4 to 122 deg F |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 10100 | Earth strap w/clamp assy | Request quotation |
| TS 10122 | Quick connect FKM | Request quotation |
| TS 10182 | Storage tube S2-Q2 with load standard | Request quotation |
| TS 10183 | Storage tube S1-Q2 standard | Request quotation |
| TS 10184 | Storage tube 1'' S1-Q1 standard | Request quotation |
| TS 10186 | Storage tube 1'' S1-Q1 chemical | Request quotation |
| TS 10187 | Storage tube S1-Q2 chemical for UTImeter | Request quotation |
| TS 10188 | Storage tube S2-Q2 with load | Request quotation |
| TS 10189 | Battery holder assy | Request quotation |
| TS 10190 | Electronic box assy | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex for Closed Operation image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.