Honeywell Process Measurement & Control

Gas Analysis Equipment

GasLab Q2

GasLab Q2 continuously determines natural-gas quality without a flame, carrier gas or combustion-air supply.

GasLab Q2 continuously determines natural-gas quality without a flame, carrier gas or combustion-air supply. Infrared absorption and thermal-conductivity measurements establish parameters such as calorific value, Wobbe index, density and carbon dioxide. Its compact arrangement supports both fiscal measurement and process-control tasks where timely knowledge of changing gas quality is useful.

Models: GasLab Q2

Features & Benefits

Measurement
Infrared absorption and thermal conductivity
Parameters
Calorific value, Wobbe index, density, CO2 and methane number
  • Avoids carrier and mixed calibration gas supplies

Applications

  • Fiscal metering, turbine and burner control, biogas and gas blending

Detailed capabilities

GasLab Q2 — purpose and deployment

GasLab Q2 continuously determines natural-gas quality without a flame, carrier gas or combustion-air supply. Infrared absorption and thermal-conductivity measurements establish parameters such as calorific value, Wobbe index, density and carbon dioxide. Its compact arrangement supports both fiscal measurement and process-control tasks where timely knowledge of changing gas quality is useful.

Manufacturer reference ↗

Correlative sensor principle

GasLab Q2 measures infrared absorption associated with hydrocarbons and carbon dioxide and the mixture’s thermal conductivity. A correlated evaluation of these measurements establishes target quality values, including information about infrared-inactive components such as nitrogen. This differs from separating individual constituents in a carrier-gas chromatography column.

Manufacturer reference ↗

Continuous control information

No flame, carrier supply, mixed calibration gas or combustion air is required in the described arrangement. The analyzer supplies fast quality information for fiscal metering, gas blending, biogas and turbine or burner control. The source associates fuel-mixture optimization with efficiency and reduced downtime, while the actual gas composition remains relevant to the correlation method.

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Analysis Rate
1 Hz
Measured Parameters
Calorific Value (Superior/Inferior), Wobbe Index, density, CO2 Concentration, Methane Number, Relative Density/Specific Gravity, Model Gas Composition (CH4…C8H18, N2)

Software & Interface

Suitable Gases
Generic Natural Gases: Methane (70 to 100 mol%), Ethane+ (0 to 20 mol%), CO2 (0 to 20 mol%), Nitrogen (0 to 30 mol%), Water/O2/H2/He (<0.1 mol%)
Display Interface
7-Channel Capacitive Touch Panel, PC Software (enSuite) for Configuration, Logging, and Display

Overview

Series
Elster® GasLab

I/O Capabilities

Response Time
≤ 6 sec millisecond
Calibration Gas
Binary mixture (CH₄/CO₂), with Automatic calibration cycle

Measurement & Sensor Related (Measurement Capabilities)

Repeatability
CO₂ ≤ 0.1 mol%; Hs, Ws, ρ ≤ 0.1%
Density
0.7168 to 1.063 (0.7175 to 1.005) kg/m³, 0.04232 to 0.06277 (0.04236 to 0.05931) lbm/ft³

Environmental Conditions

Relative Humidity
0 to 95% RH (Non-Condensing)
Operational Pressure
150 to 300 kPa (22-43 psi)

Electrical Specifications

Power Supply
24 VDC ±15%, 96 W Max, 60 W Nominal
Gas Consumption
20 to 300 l/h (0.7 to 1.1 scf/hr, including adjustable bypass flow)
Flow Rate
20 to 300 l/h (0.7 to 1.1 scf/hr)

Standards & Certifications

Metrological Approvals
NMi Approval According OIML R140 Class A
Approvals
Zone 1: Ex II 2G Ex d IIC T4 Gb/Class I Div 2 Groups ABCD T4, KC Mark (Korea), TS Mark (Taiwan), TIIS (Japan) pending

Communication Interfaces

Interfaces
1x TCP/IP, 2x RS485, (4) Digital Outputs, (2) Digital Inputs, (4) Analog Outputs, Modbus via TCP/IP and Serial

Communication & Protocols

Data Logging
Integrated logging of mean values (e.g., hourly), current values, system status, external events

Applications & Compatibility

Applications
Fiscal metering, gas turbine control, burner control, biogas, gas blending

Others

Temperature Range
-13 to +131 deg F; -25 to +55 deg C
GasLab Q2 — manufacturer page values
ParameterPublished value / configuration
Analysis Rate1 Hz
Measured ParametersCalorific Value (Superior/Inferior), Wobbe Index, density, CO2 Concentration, Methane Number, Relative Density/Specific Gravity, Model Gas Composition (CH4…C8H18, N2)
Suitable GasesGeneric Natural Gases: Methane (70 to 100 mol%), Ethane+ (0 to 20 mol%), CO2 (0 to 20 mol%), Nitrogen (0 to 30 mol%), Water/O2/H2/He (<0.1 mol%)
Display Interface7-Channel Capacitive Touch Panel, PC Software (enSuite) for Configuration, Logging, and Display
SeriesElster® GasLab
Response Time≤ 6 sec millisecond
Calibration GasBinary mixture (CH₄/CO₂), with Automatic calibration cycle
RepeatabilityCO₂ ≤ 0.1 mol%; Hs, Ws, ρ ≤ 0.1%
Density0.7168 to 1.063 (0.7175 to 1.005) kg/m³, 0.04232 to 0.06277 (0.04236 to 0.05931) lbm/ft³
Relative Humidity0 to 95% RH (Non-Condensing)
Operational Pressure150 to 300 kPa (22-43 psi)
Power Supply24 VDC ±15%, 96 W Max, 60 W Nominal
Gas Consumption20 to 300 l/h (0.7 to 1.1 scf/hr, including adjustable bypass flow)
Flow Rate20 to 300 l/h (0.7 to 1.1 scf/hr)
Metrological ApprovalsNMi Approval According OIML R140 Class A
ApprovalsZone 1: Ex II 2G Ex d IIC T4 Gb/Class I Div 2 Groups ABCD T4, KC Mark (Korea), TS Mark (Taiwan), TIIS (Japan) pending
Interfaces1x TCP/IP, 2x RS485, (4) Digital Outputs, (2) Digital Inputs, (4) Analog Outputs, Modbus via TCP/IP and Serial
Data LoggingIntegrated logging of mean values (e.g., hourly), current values, system status, external events
ApplicationsFiscal metering, gas turbine control, burner control, biogas, gas blending
Temperature Range-13 to +131 deg F; -25 to +55 deg C

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

2 parts

Part NumberDescriptionEnquiry
73023525SQ2 CPU3CORE BOARD Spare partRequest quotation
73024268SQ2 Particle filter Spare partRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/transmission/gas-analysis-equipment/gaslab-q2

Last source check: 2026-11-02

GasLab Q2 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry