EnCal 3000

EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography.

EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography. Sample gas is separated into components in a column and detected for composition and energy calculations. Published versions address heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and odorant measurement, so the analytical purpose must be matched to the selected configuration.

Models: EnCal 3000

Features & Benefits

Technology
MEMS-based gas chromatography
Variants
C6/C9 heating value, biogas, e-Gas, H2S and odorization analysis
  • Provides composition information for gas energy measurement

Applications

  • Gas transmission, distribution and major gas consumers

Detailed capabilities

EnCal 3000 — purpose and deployment

EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography. Sample gas is separated into components in a column and detected for composition and energy calculations. Published versions address heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and odorant measurement, so the analytical purpose must be matched to the selected configuration.

Manufacturer reference ↗

Chromatographic measurement

The analyzer injects a sample into a carrier-gas stream and separates its components in a column. A calibrated detector records peaks whose areas correspond to component concentration. The collected composition information is then used to calculate heating value, Wobbe index and density, connecting the analysis with gas energy billing and plant control.

Manufacturer reference ↗

Analytical versions

Published versions include C6/C9 natural-gas heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and THT/TBM odorant analysis. Those are distinct measurement configurations rather than a statement that every EnCal3000 performs every analysis. Transmission, distribution and major gas users select the variant according to the constituents and energy information needed.

Manufacturer reference ↗

Specifications

Environmental Conditions

Analysis Range
Full composition up to C6+ or C9+ (option)
Operating Temperature Range
-5 to +130 deg F
Gas Composition Range
N₂: 0 to 22%, CH₄: 55 to 100%, CO₂: 0 to 20%, C₂H: 0 to 14%, C₃: 0 to 10%, C₄: 0 to 10%, neo-C₅: 0 to 0.25%, C₅: 0 to 0.25%, C₆: 0 to 0.20%, C₇: 0 to 0.1%, C₈: 0 to 0.05%, C₉+: 0 to 0.05%

I/O Capabilities

Technology Base
MEMS-based components with capillary column
Outputs
Full Gas Composition (Up To C6+ Or C9+), Heating Value, Density, Wobbe Index
Detection Limit
C5:5 ppm
Analysis Time
3 min (C6+), 5 min (C9+)

Overview

Series
Elster® EnCal 3000

Measurement & Sensor Related (Measurement Capabilities)

Repeatability
< 0.005% on BTU

Electrical Specifications

Power Supply
24 VDC, 120 W nominal (170 W peak, heated); 24 VDC, 18 W nominal (50 W peak, non-heated)

Processing & Performance Metrics

PC Requirement
Windows 2000 or Windows XP professional edition (Service Pack 1 or higher), 1000 MHz processor, 512 MB RAM, CD-rom player, free Ethernet port

Standards & Certifications

Metrological Approvals
PTB Certificate Reference No. PTB-3.31-4016861
Approvals
ATEX II2G E Ex d IIB T4, KEMA 05ATEX2191, FM Class I Div. 1 Group B, C, D (Pending), IP66, IEC 60068-2-31/64, EN 61000-6-2/4,

Communication Interfaces

Interfaces
Ethernet UTP 10 Base-T (TCP/IP), Two RS232/485 Ports (Modbus RTU/ASCII)

Dimensions & Weight

Dimensions
37 cm Base Dia x 37 cm H (14 in Dia x 14 in H)

Communication & Protocols

Data Logging
35 days Local Storage (Analysis, Events, Alarms, Averages, Chromatogram, Calibration), API 21.1, XML Format Available

Software & Interface

Configuration Software
RGC 3000

Applications & Compatibility

Applications
Natural Gas Energy Measurement, Gas Quality Control, Quantitative Analysis
EnCal 3000 — manufacturer page values
ParameterPublished value / configuration
Analysis RangeFull composition up to C6+ or C9+ (option)
Operating Temperature Range-5 to +130 deg F
Gas Composition RangeN₂: 0 to 22%, CH₄: 55 to 100%, CO₂: 0 to 20%, C₂H: 0 to 14%, C₃: 0 to 10%, C₄: 0 to 10%, neo-C₅: 0 to 0.25%, C₅: 0 to 0.25%, C₆: 0 to 0.20%, C₇: 0 to 0.1%, C₈: 0 to 0.05%, C₉+: 0 to 0.05%
Technology BaseMEMS-based components with capillary column
OutputsFull Gas Composition (Up To C6+ Or C9+), Heating Value, Density, Wobbe Index
Detection LimitC5:5 ppm
Analysis Time3 min (C6+), 5 min (C9+)
SeriesElster® EnCal 3000
Repeatability< 0.005% on BTU
Power Supply24 VDC, 120 W nominal (170 W peak, heated); 24 VDC, 18 W nominal (50 W peak, non-heated)
PC RequirementWindows 2000 or Windows XP professional edition (Service Pack 1 or higher), 1000 MHz processor, 512 MB RAM, CD-rom player, free Ethernet port
Metrological ApprovalsPTB Certificate Reference No. PTB-3.31-4016861
ApprovalsATEX II2G E Ex d IIB T4, KEMA 05ATEX2191, FM Class I Div. 1 Group B, C, D (Pending), IP66, IEC 60068-2-31/64, EN 61000-6-2/4,
InterfacesEthernet UTP 10 Base-T (TCP/IP), Two RS232/485 Ports (Modbus RTU/ASCII)
Dimensions37 cm Base Dia x 37 cm H (14 in Dia x 14 in H)
Data Logging35 days Local Storage (Analysis, Events, Alarms, Averages, Chromatogram, Calibration), API 21.1, XML Format Available
Configuration SoftwareRGC 3000
ApplicationsNatural Gas Energy Measurement, Gas Quality Control, Quantitative Analysis

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

6 parts

Part NumberDescriptionEnquiry
1.875.241BASE PLATE ENCAL 3000Request quotation
73023652Adapt-cable CPU-Intercon DI IO EnCal3000Request quotation
73025087Encal3000_Quad Assembly Heating ICB V2.2Request quotation
8754-871800-98WRAP BEZEL V3,SHORT,PC,DUBAI42,40KRequest quotation
8754-871801-01FPC BTB 70PIN 31MM CN80 NEW STIFFENERRequest quotation
8754-871801-05FREFRE,13MP AR1337 AF CAMERA,HKT5106Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/transmission/gas-analysis-equipment/encal-3000

Last source check: 2026-11-02

EnCal 3000 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.