Gas Analysis Equipment
EnCal 3000
EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography.
EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography. Sample gas is separated into components in a column and detected for composition and energy calculations. Published versions address heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and odorant measurement, so the analytical purpose must be matched to the selected configuration.
Models: EnCal 3000
Features & Benefits
- Technology
- MEMS-based gas chromatography
- Variants
- C6/C9 heating value, biogas, e-Gas, H2S and odorization analysis
- Provides composition information for gas energy measurement
Applications
- Gas transmission, distribution and major gas consumers
Detailed capabilities
EnCal 3000 — purpose and deployment
EnCal 3000 determines natural-gas constituents using microtechnology-based gas chromatography. Sample gas is separated into components in a column and detected for composition and energy calculations. Published versions address heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and odorant measurement, so the analytical purpose must be matched to the selected configuration.
Chromatographic measurement
The analyzer injects a sample into a carrier-gas stream and separates its components in a column. A calibrated detector records peaks whose areas correspond to component concentration. The collected composition information is then used to calculate heating value, Wobbe index and density, connecting the analysis with gas energy billing and plant control.
Analytical versions
Published versions include C6/C9 natural-gas heating value, biogas, hydrogen-enriched natural gas, hydrogen sulfide and THT/TBM odorant analysis. Those are distinct measurement configurations rather than a statement that every EnCal3000 performs every analysis. Transmission, distribution and major gas users select the variant according to the constituents and energy information needed.
Environmental Conditions
- Analysis Range
- Full composition up to C6+ or C9+ (option)
- Operating Temperature Range
- -5 to +130 deg F
- Gas Composition Range
- N₂: 0 to 22%, CH₄: 55 to 100%, CO₂: 0 to 20%, C₂H: 0 to 14%, C₃: 0 to 10%, C₄: 0 to 10%, neo-C₅: 0 to 0.25%, C₅: 0 to 0.25%, C₆: 0 to 0.20%, C₇: 0 to 0.1%, C₈: 0 to 0.05%, C₉+: 0 to 0.05%
I/O Capabilities
- Technology Base
- MEMS-based components with capillary column
- Outputs
- Full Gas Composition (Up To C6+ Or C9+), Heating Value, Density, Wobbe Index
- Detection Limit
- C5:5 ppm
- Analysis Time
- 3 min (C6+), 5 min (C9+)
Overview
- Series
- Elster® EnCal 3000
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- < 0.005% on BTU
Electrical Specifications
- Power Supply
- 24 VDC, 120 W nominal (170 W peak, heated); 24 VDC, 18 W nominal (50 W peak, non-heated)
Processing & Performance Metrics
- PC Requirement
- Windows 2000 or Windows XP professional edition (Service Pack 1 or higher), 1000 MHz processor, 512 MB RAM, CD-rom player, free Ethernet port
Standards & Certifications
- Metrological Approvals
- PTB Certificate Reference No. PTB-3.31-4016861
- Approvals
- ATEX II2G E Ex d IIB T4, KEMA 05ATEX2191, FM Class I Div. 1 Group B, C, D (Pending), IP66, IEC 60068-2-31/64, EN 61000-6-2/4,
Communication Interfaces
- Interfaces
- Ethernet UTP 10 Base-T (TCP/IP), Two RS232/485 Ports (Modbus RTU/ASCII)
Dimensions & Weight
- Dimensions
- 37 cm Base Dia x 37 cm H (14 in Dia x 14 in H)
Communication & Protocols
- Data Logging
- 35 days Local Storage (Analysis, Events, Alarms, Averages, Chromatogram, Calibration), API 21.1, XML Format Available
Software & Interface
- Configuration Software
- RGC 3000
Applications & Compatibility
- Applications
- Natural Gas Energy Measurement, Gas Quality Control, Quantitative Analysis
| Parameter | Published value / configuration |
|---|---|
| Analysis Range | Full composition up to C6+ or C9+ (option) |
| Operating Temperature Range | -5 to +130 deg F |
| Gas Composition Range | N₂: 0 to 22%, CH₄: 55 to 100%, CO₂: 0 to 20%, C₂H: 0 to 14%, C₃: 0 to 10%, C₄: 0 to 10%, neo-C₅: 0 to 0.25%, C₅: 0 to 0.25%, C₆: 0 to 0.20%, C₇: 0 to 0.1%, C₈: 0 to 0.05%, C₉+: 0 to 0.05% |
| Technology Base | MEMS-based components with capillary column |
| Outputs | Full Gas Composition (Up To C6+ Or C9+), Heating Value, Density, Wobbe Index |
| Detection Limit | C5:5 ppm |
| Analysis Time | 3 min (C6+), 5 min (C9+) |
| Series | Elster® EnCal 3000 |
| Repeatability | < 0.005% on BTU |
| Power Supply | 24 VDC, 120 W nominal (170 W peak, heated); 24 VDC, 18 W nominal (50 W peak, non-heated) |
| PC Requirement | Windows 2000 or Windows XP professional edition (Service Pack 1 or higher), 1000 MHz processor, 512 MB RAM, CD-rom player, free Ethernet port |
| Metrological Approvals | PTB Certificate Reference No. PTB-3.31-4016861 |
| Approvals | ATEX II2G E Ex d IIB T4, KEMA 05ATEX2191, FM Class I Div. 1 Group B, C, D (Pending), IP66, IEC 60068-2-31/64, EN 61000-6-2/4, |
| Interfaces | Ethernet UTP 10 Base-T (TCP/IP), Two RS232/485 Ports (Modbus RTU/ASCII) |
| Dimensions | 37 cm Base Dia x 37 cm H (14 in Dia x 14 in H) |
| Data Logging | 35 days Local Storage (Analysis, Events, Alarms, Averages, Chromatogram, Calibration), API 21.1, XML Format Available |
| Configuration Software | RGC 3000 |
| Applications | Natural Gas Energy Measurement, Gas Quality Control, Quantitative Analysis |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
6 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1.875.241 | BASE PLATE ENCAL 3000 | Request quotation |
| 73023652 | Adapt-cable CPU-Intercon DI IO EnCal3000 | Request quotation |
| 73025087 | Encal3000_Quad Assembly Heating ICB V2.2 | Request quotation |
| 8754-871800-98 | WRAP BEZEL V3,SHORT,PC,DUBAI42,40K | Request quotation |
| 8754-871801-01 | FPC BTB 70PIN 31MM CN80 NEW STIFFENER | Request quotation |
| 8754-871801-05FRE | FRE,13MP AR1337 AF CAMERA,HKT5106 | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/gas/transmission/gas-analysis-equipment/encal-3000