Gas Analysis Equipment
EnCal 3000 proChain
EnCal 3000 proChain is an online gas chromatograph for natural-gas composition and heating-value measurement.
EnCal 3000 proChain is an online gas chromatograph for natural-gas composition and heating-value measurement. Its MEMS-based measuring arrangement minimizes internal volume to reduce helium use. The manufacturer emphasizes a design with one moving part and low maintenance needs, addressing reliable measurement where custody transfer and industrial energy accounting depend on gas quality information.
Models: EnCal 3000 proChain
Features & Benefits
- Technology
- MEMS-based chromatography
- Mechanical design
- One moving part
- Low helium consumption reduces bottle replacement and operating effort
Applications
- Custody transfer, gas transmission and distribution, industrial energy users
Detailed capabilities
EnCal 3000 proChain — purpose and deployment
EnCal 3000 proChain is an online gas chromatograph for natural-gas composition and heating-value measurement. Its MEMS-based measuring arrangement minimizes internal volume to reduce helium use. The manufacturer emphasizes a design with one moving part and low maintenance needs, addressing reliable measurement where custody transfer and industrial energy accounting depend on gas quality information.
Low-volume MEMS chromatography
The proChain measuring design reduces internal volume and helium use. The source describes a typical bottle replacement interval of seven years and a single moving part to reduce wear. These published operating comparisons support lower servicing effort, but their wording remains typical or conditional rather than a guaranteed interval at every installation.
Secure data and service-life benefits
Secure development, controlled configuration and protected communication are identified as means of preserving measurement data. The source also claims that extended asset service can defer replacement by up to five years. The intended applications include fiscal measurement, incoming gas-quality checks, burner control and industrial energy management alongside transmission and distribution.
Who uses the measurements
Transmission and distribution operators, industrial energy users and custody-transfer service teams are the published audience. The final section links lower-maintenance composition analysis with billing accuracy, unaccounted gas and methane-reporting pressures. It supplies measurement information for those tasks without claiming that the chromatograph itself measures methane emissions directly.
Environmental Conditions
- Analysis Range
- Up to C6+
- Operating Temperature Range
- Safety: -40 to +60 deg C; Metrology: -25 to +55 deg C
- Gas Composition Range
- CH4: 55 to 100%, N2: 0 to 20%, CO2: 0 to 20%, C2H6: 0 to 30%, C3H8: 0 to 20%, i-C4H10: 0 to 3%, n-C4H10: 0 to 3%, neo to C5H12: 0 to 1%, i-C5H12: 0 to 1%, n-C5H12: 0 to 1%, C6+: 0 to 0.5
Overview
- Series
- Elster® EnCal 3000
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- =0.015% for calculated Heating values
Electrical Specifications
- Power Supply
- No Heating: 24 VDC/3 A (16 W Typical, 30 W Max, 60 W Peak); With Heaters: 24 VDC/5A (max 120 W)
Processing & Performance Metrics
- PC Requirement
- Windows 7+, 1024x768 graphics, 10GB HDD, 1GB RAM, Java SE 8
Standards & Certifications
- Metrological Approvals
- NMi Approval According OIML R140 Class A
- Approvals
- ATEX/IECEx/NEPSI: Exd Zone 1 IIC T6; EMC EN 61000-6-2/4; cCSAus: Class I/Div 1 BCD
Communication Interfaces
- Interfaces
- Internal/External USB, Ethernet (ModBus/Config), 2x RS485 (ModBus), Digital I/O
Dimensions & Weight
- Dimensions
- 37 cm Base Dia x 37 cm H (14 in Dia x 14 in H)
Communication & Protocols
- Data Logging
- 2000 chromatograms (~4 days); Local storage: last 100 days (analysis%, events%, alarms%, averages%, calibration)
Analytical / Technical Specifications
- Analytical Hardware
- 2 MEMS Columns/single Column Train, Backflush-to-detector Configuration, Temperature Ramped
I/O Capabilities
- Analysis Time
- 3 min for C6+ Analysis
| Parameter | Published value / configuration |
|---|---|
| Analysis Range | Up to C6+ |
| Operating Temperature Range | Safety: -40 to +60 deg C; Metrology: -25 to +55 deg C |
| Gas Composition Range | CH4: 55 to 100%, N2: 0 to 20%, CO2: 0 to 20%, C2H6: 0 to 30%, C3H8: 0 to 20%, i-C4H10: 0 to 3%, n-C4H10: 0 to 3%, neo to C5H12: 0 to 1%, i-C5H12: 0 to 1%, n-C5H12: 0 to 1%, C6+: 0 to 0.5 |
| Series | Elster® EnCal 3000 |
| Repeatability | =0.015% for calculated Heating values |
| Power Supply | No Heating: 24 VDC/3 A (16 W Typical, 30 W Max, 60 W Peak); With Heaters: 24 VDC/5A (max 120 W) |
| PC Requirement | Windows 7+, 1024x768 graphics, 10GB HDD, 1GB RAM, Java SE 8 |
| Metrological Approvals | NMi Approval According OIML R140 Class A |
| Approvals | ATEX/IECEx/NEPSI: Exd Zone 1 IIC T6; EMC EN 61000-6-2/4; cCSAus: Class I/Div 1 BCD |
| Interfaces | Internal/External USB, Ethernet (ModBus/Config), 2x RS485 (ModBus), Digital I/O |
| Dimensions | 37 cm Base Dia x 37 cm H (14 in Dia x 14 in H) |
| Data Logging | 2000 chromatograms (~4 days); Local storage: last 100 days (analysis%, events%, alarms%, averages%, calibration) |
| Analytical Hardware | 2 MEMS Columns/single Column Train, Backflush-to-detector Configuration, Temperature Ramped |
| Analysis Time | 3 min for C6+ Analysis |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
EnCal 3000 proChain image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.