HON 300 regulates gas pressure using an inlet-pressure-compensated diaphragm assembly.

HON 300 regulates gas pressure using an inlet-pressure-compensated diaphragm assembly. It is suited to dynamic duties such as gas furnaces and offers internal or external impulse connection choices. Replaceable functional cartridges simplify service, while optional safety shut-off, relief or safety-diaphragm arrangements depend on the selected regulating assembly and pressure range.

Models: HON 300

Features & Benefits

Maximum admissible pressure
16 bar
Outlet range
20 mbar–2 bar
Construction
Replaceable functional cartridge
  • Dynamic response supports changing process loads

Applications

  • Gas furnaces and pressure regulating lines

Detailed capabilities

HON 300 — operating design

HON 300 regulates gas pressure using an inlet-pressure-compensated diaphragm assembly. It is suited to dynamic duties such as gas furnaces and offers internal or external impulse connection choices. Replaceable functional cartridges simplify service, while optional safety shut-off, relief or safety-diaphragm arrangements depend on the selected regulating assembly and pressure range.

Manufacturer reference ↗

Replaceable regulating and safety assemblies

HON 300 has internal or external impulse choices and a compensated diaphragm for dynamic demand. Its normal assembly may include relief within the specified lower outlet range; alternatives include the HON 915 vent arrangement or a safety diaphragm. A shut-off can be included or omitted, with K1a or K2a control elements identified. Cartridge construction allows functional replacement without dismantling the entire station line.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 300. Version, size and option qualifications remain attached to each fact.

  • Maximum Permissible Pressure: 16 bar
  • Lock-up Pressure Zone Class: SZ 2.5
  • Temperature Range: -20 to +60 deg C
  • Connection Type: Class 150 (ANSI 16.5) on request; Flange PN 16
  • Pipe Size: DN 25
  • Suitable Gases: Gases per DVGW worksheet G 260; Neutral, non-aggressive gases; Other gases on request

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Maximum Permissible Pressure
16 bar

Mechanical & Physical Properties

Lock-up Pressure Zone Class
SZ 2.5

Standards & Certifications

Explosion Protection
All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.

Environmental Conditions

Temperature Range
-20 to +60 deg C

Technical Specifications

Connection Type
Class 150 (ANSI 16.5) on request; Flange PN 16
Pipe Size
DN 25

Software & Interface

Suitable Gases
Gases per DVGW worksheet G 260; Neutral, non-aggressive gases; Other gases on request

Material Specifications

Body Material
Cast Aluminum Alloy

Applications & Compatibility

Applications
Component for gas appliances (EC Directive 90/396/EEC); Direct acting gas pressure regulator for systems per DVGW G 491 (A), G 600 (A) (TRGI); Dynamic regulating lines (gas furnaces, burner switching, gas engine operation)
HON 300 — manufacturer page values
ParameterPublished value / configuration
Maximum Permissible Pressure16 bar
Lock-up Pressure Zone ClassSZ 2.5
Explosion ProtectionAll mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
Temperature Range-20 to +60 deg C
Connection TypeClass 150 (ANSI 16.5) on request; Flange PN 16
Pipe SizeDN 25
Suitable GasesGases per DVGW worksheet G 260; Neutral, non-aggressive gases; Other gases on request
Body MaterialCast Aluminum Alloy
ApplicationsComponent for gas appliances (EC Directive 90/396/EEC); Direct acting gas pressure regulator for systems per DVGW G 491 (A), G 600 (A) (TRGI); Dynamic regulating lines (gas furnaces, burner switching, gas engine operation)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

5 parts

Part NumberDescriptionEnquiry
BD305LPSERIES 305LP SAFETY CUT OFF VALVERequest quotation
BD305MPSERIES 305MP SAFETY CUT OFF VALVERequest quotation
HON300Gas Pressure Regulator HON 300Request quotation
HON300_DADiaphragm Assembly for HON 300Request quotation
HON_SSV_CARTRIDGESafety Shut Off CartridgeRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/medium-pressure-regulators-pn16-ansi-150/hon-300

Last source check: 2026-11-02

HON 300 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry