SmartLine Wireless Transmitters
SmartLine Wireless Differential Pressure
SmartLine wireless differential-pressure transmitters provide measurements from remote and hazardous plant locations through OneWireless infrastructure.
SmartLine wireless differential-pressure transmitters provide measurements from remote and hazardous plant locations through OneWireless infrastructure. Series 700 and 800 offer different model ranges, including low differential-pressure service and higher-pressure duties. Honeywell identifies combustion airflow as a use, with the selected range and network arrangement determining the instrument's role in the monitoring application.
Models: STDW810, STDW820, STDW830, STDW870, STDW720, STDW730, STDW770
Features & Benefits
- Series
- 700 and 800
- Measurement
- Differential pressure
- Reduces wiring needs for remote measurements
Applications
- Combustion airflow and differential-pressure monitoring
Detailed capabilities
Differential model and range selection
Series 700 offers STDW720, STDW730 and STDW770, while Series 800 adds STDW810/820/830/870. Their ranges are model-specific, from the low differential span of STDW810 through the high-pressure group. The source table must remain the selection reference; the whole family cannot be described as one pressure range merely because it shares a wireless network and enclosure concept.
How Does It Work?
OneWireless carries the pressure data over the described multiprotocol network, with half-second publication and anti-alias filtering available as options in this generation. ISA100 Wireless and WirelessHART coexist in the network alongside the stated legacy/future connectivity paths. The passage describes deterministic, scalable infrastructure, not a claim that any unconfigured radio link is automatically suitable for a particular safety or control task.
What Problems Does It Solve?
Remote/hazardous points become easier to instrument without a new wired route, reducing installation barriers and startup work. The page highlights commodity batteries, optional field DC power and reduced-noise operation for control applications. Model range and the selected update/power arrangement remain separate engineering choices, with the existing XYR6000 integration path supporting staged network expansion.
Product videos
Processing & Performance Metrics
- Accuracy
- STDW720/730: ±0.065%; STDW770: ±0.175%; STDW810/820: ±0.0375% of span or URV; STDW830: ±0.065%; STDW870: ±0.125%
I/O Capabilities
- Zero Suppression
- -5 to +100% URL
Communication & Protocols
- Wireless Protocol
- ISA100 Wireless (2.4 GHz ISM band, DSSS, IEEE 802.15.4)
Environmental Conditions
- Temperature Effect
- STDW720/730: Zero ±0.15 to 0.2%, Combined ±0.225 to 0.275%; STDW770: Zero ±0.2%, Combined ±0.3%; STDW810/820: Zero ±0.2% of span per 28 deg C, Combined ±0.225%; STDW830: Zero ±0.05%, Combined ±0.075%; STDW870: Zero ±0.1%, Combined ±0.15%
- Signal Range
- Up to 350 m (1150 ft) with 4 dBi antenna (line of sight)
- Shock/Vibration
- Shock: Max 40g; Vibration: Max 4g over 15 to 200Hz
- Relative Humidity
- 0 to 100% RH (Non-Condensing)
- Operating Temperature Range
- -40 to +85 deg C (-40 to +185 deg F)
Electrical Specifications
- Power Supply
- 3.6 V Lithium thionyl chloride (LiSOCl2), D Size, Non-Rechargeable (24 VDC Option)
Overview
- Models
- STDW810: 0 to 10 in H₂O (0 to 25 mbar), STDW820: 0 to 400 in H₂O (0 to 1000 mbar), STDW830: 0 to 100 psi (0 to 7 bar), STDW870: 0 to 3000 psi (0 to 210 bar), STDW720: 0 to 400 in H₂O (0 to 1000 mbar), STDW730: 0 to 100 psi (0 to 7 bar), STDW770: 0 to 3000 psi (0 to 210 bar)
Material Specifications
- Housing Material
- Epoxy-Polyester Coated Aluminum, 316 Stainless Steel (CF8M)
Mechanical & Physical Properties
- Enclosure
- Type 4X, IP66/IP67
Standards & Certifications
- Approvals
- CE Conformity ETSI EN 300 328 V2.1.1, EN61326-1 2013, CSA, FM, ATEX, IECEx
Technical Specifications
- Series
- Models | Operating Range
- 700
- STDW720 | 0-400 in H2O (0-1000 mbar)
- STDW730
- 0-100 psi (0-7 bar)
- STDW770
- 0-3000 psi (0-210 bar)
- 800
- STDW810 | 0-10 in H2O (0-25 mbar)
- STDW820
- 0-400 in H2O (0-1000 mbar)
- STDW830
- 0-100 psi (0-7 bar)
- STDW870
- 0-3000 psi (0-210 bar)
| Parameter | Published value / configuration |
|---|---|
| Accuracy | STDW720/730: ±0.065%; STDW770: ±0.175%; STDW810/820: ±0.0375% of span or URV; STDW830: ±0.065%; STDW870: ±0.125% |
| Zero Suppression | -5 to +100% URL |
| Wireless Protocol | ISA100 Wireless (2.4 GHz ISM band, DSSS, IEEE 802.15.4) |
| Temperature Effect | STDW720/730: Zero ±0.15 to 0.2%, Combined ±0.225 to 0.275%; STDW770: Zero ±0.2%, Combined ±0.3%; STDW810/820: Zero ±0.2% of span per 28 deg C, Combined ±0.225%; STDW830: Zero ±0.05%, Combined ±0.075%; STDW870: Zero ±0.1%, Combined ±0.15% |
| Signal Range | Up to 350 m (1150 ft) with 4 dBi antenna (line of sight) |
| Shock/Vibration | Shock: Max 40g; Vibration: Max 4g over 15 to 200Hz |
| Relative Humidity | 0 to 100% RH (Non-Condensing) |
| Operating Temperature Range | -40 to +85 deg C (-40 to +185 deg F) |
| Power Supply | 3.6 V Lithium thionyl chloride (LiSOCl2), D Size, Non-Rechargeable (24 VDC Option) |
| Models | STDW810: 0 to 10 in H₂O (0 to 25 mbar), STDW820: 0 to 400 in H₂O (0 to 1000 mbar), STDW830: 0 to 100 psi (0 to 7 bar), STDW870: 0 to 3000 psi (0 to 210 bar), STDW720: 0 to 400 in H₂O (0 to 1000 mbar), STDW730: 0 to 100 psi (0 to 7 bar), STDW770: 0 to 3000 psi (0 to 210 bar) |
| Housing Material | Epoxy-Polyester Coated Aluminum, 316 Stainless Steel (CF8M) |
| Enclosure | Type 4X, IP66/IP67 |
| Approvals | CE Conformity ETSI EN 300 328 V2.1.1, EN61326-1 2013, CSA, FM, ATEX, IECEx |
| Series | Models | Operating Range |
| 700 | STDW720 | 0-400 in H2O (0-1000 mbar) |
| STDW730 | 0-100 psi (0-7 bar) |
| STDW770 | 0-3000 psi (0-210 bar) |
| 800 | STDW810 | 0-10 in H2O (0-25 mbar) |
| STDW820 | 0-400 in H2O (0-1000 mbar) |
| STDW830 | 0-100 psi (0-7 bar) |
| STDW870 | 0-3000 psi (0-210 bar) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 50000547-501 | PLUG KIT DH M20 SS | Request quotation |
| 50000547-502 | PLUG KIT DH M20 CS | Request quotation |
| 50018278-501 | 1.0M LIG PROT CABLE B-TYP N-N | Request quotation |
| 50018278-503 | 3.0M LIT PROT CABLE B-TYPE N-N | Request quotation |
| 50018278-510 | 10.0M LIT PRO CABLE B-TYPE N-N | Request quotation |
| 50018279-590 | REMOTE SURGE ARRESTOR FHSS ANT | Request quotation |
| 50018414-501 | 8 DBI REMOTE OMNI FHSS ANTENNA | Request quotation |
| 50018415-501 | REMOTE DIRECTIONAL 14DBI ANTEN | Request quotation |
| 50021832-501 | KIT PLUG PIPE HEADLESS SKT | Request quotation |
| 50021832-502 | CONDUIT PLUG 1/2NPT(SS) | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Smartline_Wireless_Pressure-Differential Transmitter Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.