VersaFlow vortex meters measure steam, gases and low-viscosity liquids using a two-wire instrument design.
VersaFlow vortex meters measure steam, gases and low-viscosity liquids using a two-wire instrument design. Temperature compensation is built in, with pressure compensation available as an option. Wafer versions cover DN15–DN100, while flanged versions extend to DN300, giving users a choice of process connection and size for industrial flow measurement duties.
Features & Benefits
- Compensation
- Integrated temperature
- Connections
- Wafer DN15–DN100 or flanged DN15–DN300
Applications
- Steam, gas and low-viscosity liquid flow measurement
Mechanical & Physical Properties
- Sizes
- DN 15 to DN 300 (1/2 to 12 in)
Environmental Conditions
- Operating Temperature Range
- Medium: -40 to +240 deg C (-40 to +465 deg F); Ambient: -40 to +85 deg C (Non-Ex), -40 to +65 deg C (Ex)
- Operating Pressure
- Up to 100 bar (1450 psi), higher on request
Technical Specifications
- Electrical Connections
- 2-wire, 12 to 36 VDC (Non-Ex), 12 to 30 VDC (Ex i), 12 to 36 VDC (Ex d)
- Process Connections
- ASME B16.5: 1/2 to 12 in, 150 to 600 lb), Sandwich (EN: DN 15 to 100, PN 100; ASME: 1/2 to 4 in, 600 lb); Flange (EN 1092-1: DN15 to 300, PN16 to 100
- Measurable Media
- Conductive and Non-Conductive Liquids, Gases, Vapors, Saturated and Superheated Steam
Standards & Certifications
- Ingress Protection
- IP66, IP67 (Compact and Remote Versions)
- Approvals
- ATEX: (Ex ia, Ex d ia, Ex nA, Ex tb), IECEx: Same as ATEX, QPS (USA and Canada): (IS, XP, NI, DIP)
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- ±0.1% of Measured Value
Electrical Specifications
- Nominal Sizes
- DN 15 to DN 300 (EN), 1/2 to 12 in (ASME)
- Power Supply
- Non-Ex: 12-36 VDC, Ex i: 12-30 VDC, Ex d: 12-36 VDC
Applications & Compatibility
- Applications
- Steam Boiler Monitoring, Compressor Output, Heat Metering, Industrial Gases, Compressed Air, SIP/CIP Processes
- Mounting
- Horizontal, Vertical Or Angled (With Restrictions For Steam/Liquid)
Industries / Applications & Compatibility
- Industries
- Oil and Gas, Chemical, Power, Metals, Pulp and Paper, Water, Automotive, Food and Beverage
Material Specifications
- Materials
- Option: Hastelloy® C-22 (Wetted Parts); Standard: 316L Stainless Steel (1.4404)
Processing & Performance Metrics
- Accuracy
- Gases/Steam: ±1.0% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000); Liquids: ±0.75% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000)
I/O Capabilities
- Outputs
- 4 to 20 mA (Passive), Pulse, Frequency, Status, Limit Switch, HART® 7 Protocol
- Inputs
- 4 to 20 mA (Passive)
Software & Interface
- Display
- Graphic display; Multilingual (German, English, French, Italian, Spanish, Russian, Chinese, Swedish, Danish, Czech, Polish)
| Parameter | Published value / configuration |
|---|---|
| Sizes | DN 15 to DN 300 (1/2 to 12 in) |
| Operating Temperature Range | Medium: -40 to +240 deg C (-40 to +465 deg F); Ambient: -40 to +85 deg C (Non-Ex), -40 to +65 deg C (Ex) |
| Operating Pressure | Up to 100 bar (1450 psi), higher on request |
| Electrical Connections | 2-wire, 12 to 36 VDC (Non-Ex), 12 to 30 VDC (Ex i), 12 to 36 VDC (Ex d) |
| Process Connections | ASME B16.5: 1/2 to 12 in, 150 to 600 lb), Sandwich (EN: DN 15 to 100, PN 100; ASME: 1/2 to 4 in, 600 lb); Flange (EN 1092-1: DN15 to 300, PN16 to 100 |
| Measurable Media | Conductive and Non-Conductive Liquids, Gases, Vapors, Saturated and Superheated Steam |
| Ingress Protection | IP66, IP67 (Compact and Remote Versions) |
| Approvals | ATEX: (Ex ia, Ex d ia, Ex nA, Ex tb), IECEx: Same as ATEX, QPS (USA and Canada): (IS, XP, NI, DIP) |
| Repeatability | ±0.1% of Measured Value |
| Nominal Sizes | DN 15 to DN 300 (EN), 1/2 to 12 in (ASME) |
| Power Supply | Non-Ex: 12-36 VDC, Ex i: 12-30 VDC, Ex d: 12-36 VDC |
| Applications | Steam Boiler Monitoring, Compressor Output, Heat Metering, Industrial Gases, Compressed Air, SIP/CIP Processes |
| Mounting | Horizontal, Vertical Or Angled (With Restrictions For Steam/Liquid) |
| Industries | Oil and Gas, Chemical, Power, Metals, Pulp and Paper, Water, Automotive, Food and Beverage |
| Materials | Option: Hastelloy® C-22 (Wetted Parts); Standard: 316L Stainless Steel (1.4404) |
| Accuracy | Gases/Steam: ±1.0% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000); Liquids: ±0.75% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000) |
| Outputs | 4 to 20 mA (Passive), Pulse, Frequency, Status, Limit Switch, HART® 7 Protocol |
| Inputs | 4 to 20 mA (Passive) |
| Display | Graphic display; Multilingual (German, English, French, Italian, Spanish, Russian, Chinese, Swedish, Danish, Czech, Polish) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| VM20 | VERSAFLOW VORTEX 200 FLANGED | Request quotation |
| VM21 | VERSAFLOW VORTEX 200 SANDWICH | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
VersaFlow Vortex Shedding Flow Meter Image · Manufacturer ownership retained; republication licence not independently confirmed
VersaFlow Vortex Shedding Flow Meter Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.