VersaFlow vortex meters measure steam, gases and low-viscosity liquids using a two-wire instrument design.

VersaFlow vortex meters measure steam, gases and low-viscosity liquids using a two-wire instrument design. Temperature compensation is built in, with pressure compensation available as an option. Wafer versions cover DN15–DN100, while flanged versions extend to DN300, giving users a choice of process connection and size for industrial flow measurement duties.

Features & Benefits

Compensation
Integrated temperature
Connections
Wafer DN15–DN100 or flanged DN15–DN300

Applications

  • Steam, gas and low-viscosity liquid flow measurement

Specifications

Mechanical & Physical Properties

Sizes
DN 15 to DN 300 (1/2 to 12 in)

Environmental Conditions

Operating Temperature Range
Medium: -40 to +240 deg C (-40 to +465 deg F); Ambient: -40 to +85 deg C (Non-Ex), -40 to +65 deg C (Ex)
Operating Pressure
Up to 100 bar (1450 psi), higher on request

Technical Specifications

Electrical Connections
2-wire, 12 to 36 VDC (Non-Ex), 12 to 30 VDC (Ex i), 12 to 36 VDC (Ex d)
Process Connections
ASME B16.5: 1/2 to 12 in, 150 to 600 lb), Sandwich (EN: DN 15 to 100, PN 100; ASME: 1/2 to 4 in, 600 lb); Flange (EN 1092-1: DN15 to 300, PN16 to 100
Measurable Media
Conductive and Non-Conductive Liquids, Gases, Vapors, Saturated and Superheated Steam

Standards & Certifications

Ingress Protection
IP66, IP67 (Compact and Remote Versions)
Approvals
ATEX: (Ex ia, Ex d ia, Ex nA, Ex tb), IECEx: Same as ATEX, QPS (USA and Canada): (IS, XP, NI, DIP)

Measurement & Sensor Related (Measurement Capabilities)

Repeatability
±0.1% of Measured Value

Electrical Specifications

Nominal Sizes
DN 15 to DN 300 (EN), 1/2 to 12 in (ASME)
Power Supply
Non-Ex: 12-36 VDC, Ex i: 12-30 VDC, Ex d: 12-36 VDC

Applications & Compatibility

Applications
Steam Boiler Monitoring, Compressor Output, Heat Metering, Industrial Gases, Compressed Air, SIP/CIP Processes
Mounting
Horizontal, Vertical Or Angled (With Restrictions For Steam/Liquid)

Industries / Applications & Compatibility

Industries
Oil and Gas, Chemical, Power, Metals, Pulp and Paper, Water, Automotive, Food and Beverage

Material Specifications

Materials
Option: Hastelloy® C-22 (Wetted Parts); Standard: 316L Stainless Steel (1.4404)

Processing & Performance Metrics

Accuracy
Gases/Steam: ±1.0% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000); Liquids: ±0.75% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000)

I/O Capabilities

Outputs
4 to 20 mA (Passive), Pulse, Frequency, Status, Limit Switch, HART® 7 Protocol
Inputs
4 to 20 mA (Passive)

Software & Interface

Display
Graphic display; Multilingual (German, English, French, Italian, Spanish, Russian, Chinese, Swedish, Danish, Czech, Polish)
VersaFlow Vortex Shedding Flow Meter — manufacturer page values
ParameterPublished value / configuration
SizesDN 15 to DN 300 (1/2 to 12 in)
Operating Temperature RangeMedium: -40 to +240 deg C (-40 to +465 deg F); Ambient: -40 to +85 deg C (Non-Ex), -40 to +65 deg C (Ex)
Operating PressureUp to 100 bar (1450 psi), higher on request
Electrical Connections2-wire, 12 to 36 VDC (Non-Ex), 12 to 30 VDC (Ex i), 12 to 36 VDC (Ex d)
Process ConnectionsASME B16.5: 1/2 to 12 in, 150 to 600 lb), Sandwich (EN: DN 15 to 100, PN 100; ASME: 1/2 to 4 in, 600 lb); Flange (EN 1092-1: DN15 to 300, PN16 to 100
Measurable MediaConductive and Non-Conductive Liquids, Gases, Vapors, Saturated and Superheated Steam
Ingress ProtectionIP66, IP67 (Compact and Remote Versions)
ApprovalsATEX: (Ex ia, Ex d ia, Ex nA, Ex tb), IECEx: Same as ATEX, QPS (USA and Canada): (IS, XP, NI, DIP)
Repeatability±0.1% of Measured Value
Nominal SizesDN 15 to DN 300 (EN), 1/2 to 12 in (ASME)
Power SupplyNon-Ex: 12-36 VDC, Ex i: 12-30 VDC, Ex d: 12-36 VDC
ApplicationsSteam Boiler Monitoring, Compressor Output, Heat Metering, Industrial Gases, Compressed Air, SIP/CIP Processes
MountingHorizontal, Vertical Or Angled (With Restrictions For Steam/Liquid)
IndustriesOil and Gas, Chemical, Power, Metals, Pulp and Paper, Water, Automotive, Food and Beverage
MaterialsOption: Hastelloy® C-22 (Wetted Parts); Standard: 316L Stainless Steel (1.4404)
AccuracyGases/Steam: ±1.0% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000); Liquids: ±0.75% (Re ≥ 20,000), ±2.0% (10,000 < Re < 20,000)
Outputs4 to 20 mA (Passive), Pulse, Frequency, Status, Limit Switch, HART® 7 Protocol
Inputs4 to 20 mA (Passive)
DisplayGraphic display; Multilingual (German, English, French, Italian, Spanish, Russian, Chinese, Swedish, Danish, Czech, Polish)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

2 parts

Part NumberDescriptionEnquiry
VM20VERSAFLOW VORTEX 200 FLANGEDRequest quotation
VM21VERSAFLOW VORTEX 200 SANDWICHRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/field-instruments/flow-meters/versaflow-vortex-shedding-flow-meter

Last source check: 2026-11-02

VersaFlow Vortex Shedding Flow Meter Image · Manufacturer ownership retained; republication licence not independently confirmed

VersaFlow Vortex Shedding Flow Meter Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry