Flow Meters
VersaFlow Coriolis Flowmeter
VersaFlow Coriolis meters combine mass-flow measurement with density, temperature and concentration measurement.
VersaFlow Coriolis meters combine mass-flow measurement with density, temperature and concentration measurement. Honeywell offers four sensor families covering different line sizes and application demands, with straight-tube and bent-tube designs. Pairing the sensor with the TWC9400 converter adds entrained-gas measurement capability, allowing the system configuration to reflect the process fluid and installation requirements.
Features & Benefits
- Sensor families
- Coriolis 100, 1000, 200 and 6000
- Converter
- TWC9400 with EGM capability
Applications
- Mass and volumetric flow measurement
Processing & Performance Metrics
- Accuracy
- ±0.05% (Optional, not in SIL Mode) (Liquid); ±0.1% of Actual Measured Flow Rate (standard); ±0.35% of Actual Measured Flow Rate + Zero Stability (Gas)
- Zero Stability
- As low as ±0.004% of max flow (Titanium, 1000), ±0.01% (100), see model for details
- Maximum Flow Rate
- Up to 170,000 kg/h (Coriolis 100) gallons per minute; Up to 420,000 kg/h (Coriolis 200) gallons per minute; Up to 550,000 kg/h (Coriolis 6000) gallons per minute; Up to 560,000 kg/h (Coriolis 1000) gallons per minute
Material Specifications
- Tube Material
- Stainless Steel, Hastelloy®, Titanium, Tantalum, Super Duplex (model dependent)
Environmental Conditions
- Temperature Range
- Coriolis 100: -40 to +130 deg C, Coriolis 1000: -40 to +150 deg C (Ti), 0 to +100 deg C (SS), Coriolis 200: -45 to +130 deg C, Coriolis 6000: -200 to +400 deg C (extended)
- Nominal Pressure
- Up to 100 barg (others) bar (air pressure); Up to 180 barg (Coriolis 200, Super Duplex) bar (air pressure); Up to 200 barg (Coriolis 6000, Hastelloy) bar (air pressure)
- Ambient Temperature Range
- -40 to +55 deg C (Compact Stainless Steel); -40 to +65 deg C (Remote); -40 to +65 deg C (Standard, Compact Aluminum)
Overview
- Sensor Models
- Coriolis 100 (General Purpose, Twin Tube), Coriolis 1000 (Straight Tube, High Purity/Chemicals), Coriolis 200 (Bulk, Large Diameter, Oil and Gas), Coriolis 6000 (Twin V-Tube, Extended Temp, Cryogenic)
Functional & Control Features
- Self-Diagnostics
- NAMUR NE107, Advanced Diagnostics, Entrained Gas Management (EGM), Redundant Calibration
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- Liquid: better than 0.05% + zero stability, Gas: better than 0.2% + zero stability
- Measured Variables
- Mass Flow, Density, Temperature (Direct); Volume, Concentration, Velocity (Calculated)
- Converter
- TWC9400 (compact or remote, Ex/non-Ex, HART/Modbus)
Standards & Certifications
- Protection Category
- IP67 (NEMA 4X) (All models)
- Approvals
- CE Mark with PED, FM/CSA (Class I/II/III Div 1/2), IECEx, ATEX, OIML R117-1 (Custody Transfer), NACE, CRN
Technical Specifications
- Process Connections
- Flanges: DIN, ASME, JIS (various ratings), Hygienic: Tri-clamp, DIN 32676, ISO 2852, DIN 11864-2, SMS, IDF/ISS, RJT (model dependent)
- Density
- 100 to 3000 kg/m³ (6000), 400 to 2500 kg/m³ (100/1000)
I/O Capabilities
- Outputs/Comms
- Current (Active/Passive, HART®), Pulse, Frequency, Status, Modbus, Limit Switch, Control Input
- Installation
- Can be mounted at angle, horizontal, or vertical (prefer uphill flow); No straight runs required
Electrical Specifications
- Nominal Sizes
- Coriolis 100: DN15 to DN50 (1/2 to 2 in), Coriolis 1000: DN04 to DN80 (1/8 to 3 in), Coriolis 200: DN100 to DN150 (4 to 6 in), Coriolis 6000: DN08 to DN200 (3/8 to 8 in)
Applications & Compatibility
- Mounting
- Compact (Integral Converter) or Remote (Field/Wall/Rack Mount, up to 300 m Cable)
- Applications
- Bulk Loading/Unloading, Custody Transfer, Pipeline Measurement, Allocation Metering, Viscous/Cryogenic Fluids, Slurries, Highly Corrosive Fluids, Products With Entrained Solids/Gas
Industries / Applications & Compatibility
- Industries
- Oil and Gas, Chemical, Petrochemical, Water and Wastewater, Food and Beverage, Pharmaceutical, Power, Mining
Software & Interface
- Display
- Graphic LCD, Backlit, Rotatable, Pushbutton/Optical Keys, IR Interface
| Parameter | Published value / configuration |
|---|---|
| Accuracy | ±0.05% (Optional, not in SIL Mode) (Liquid); ±0.1% of Actual Measured Flow Rate (standard); ±0.35% of Actual Measured Flow Rate + Zero Stability (Gas) |
| Zero Stability | As low as ±0.004% of max flow (Titanium, 1000), ±0.01% (100), see model for details |
| Maximum Flow Rate | Up to 170,000 kg/h (Coriolis 100) gallons per minute; Up to 420,000 kg/h (Coriolis 200) gallons per minute; Up to 550,000 kg/h (Coriolis 6000) gallons per minute; Up to 560,000 kg/h (Coriolis 1000) gallons per minute |
| Tube Material | Stainless Steel, Hastelloy®, Titanium, Tantalum, Super Duplex (model dependent) |
| Temperature Range | Coriolis 100: -40 to +130 deg C, Coriolis 1000: -40 to +150 deg C (Ti), 0 to +100 deg C (SS), Coriolis 200: -45 to +130 deg C, Coriolis 6000: -200 to +400 deg C (extended) |
| Nominal Pressure | Up to 100 barg (others) bar (air pressure); Up to 180 barg (Coriolis 200, Super Duplex) bar (air pressure); Up to 200 barg (Coriolis 6000, Hastelloy) bar (air pressure) |
| Ambient Temperature Range | -40 to +55 deg C (Compact Stainless Steel); -40 to +65 deg C (Remote); -40 to +65 deg C (Standard, Compact Aluminum) |
| Sensor Models | Coriolis 100 (General Purpose, Twin Tube), Coriolis 1000 (Straight Tube, High Purity/Chemicals), Coriolis 200 (Bulk, Large Diameter, Oil and Gas), Coriolis 6000 (Twin V-Tube, Extended Temp, Cryogenic) |
| Self-Diagnostics | NAMUR NE107, Advanced Diagnostics, Entrained Gas Management (EGM), Redundant Calibration |
| Repeatability | Liquid: better than 0.05% + zero stability, Gas: better than 0.2% + zero stability |
| Measured Variables | Mass Flow, Density, Temperature (Direct); Volume, Concentration, Velocity (Calculated) |
| Converter | TWC9400 (compact or remote, Ex/non-Ex, HART/Modbus) |
| Protection Category | IP67 (NEMA 4X) (All models) |
| Approvals | CE Mark with PED, FM/CSA (Class I/II/III Div 1/2), IECEx, ATEX, OIML R117-1 (Custody Transfer), NACE, CRN |
| Process Connections | Flanges: DIN, ASME, JIS (various ratings), Hygienic: Tri-clamp, DIN 32676, ISO 2852, DIN 11864-2, SMS, IDF/ISS, RJT (model dependent) |
| Density | 100 to 3000 kg/m³ (6000), 400 to 2500 kg/m³ (100/1000) |
| Outputs/Comms | Current (Active/Passive, HART®), Pulse, Frequency, Status, Modbus, Limit Switch, Control Input |
| Installation | Can be mounted at angle, horizontal, or vertical (prefer uphill flow); No straight runs required |
| Nominal Sizes | Coriolis 100: DN15 to DN50 (1/2 to 2 in), Coriolis 1000: DN04 to DN80 (1/8 to 3 in), Coriolis 200: DN100 to DN150 (4 to 6 in), Coriolis 6000: DN08 to DN200 (3/8 to 8 in) |
| Mounting | Compact (Integral Converter) or Remote (Field/Wall/Rack Mount, up to 300 m Cable) |
| Applications | Bulk Loading/Unloading, Custody Transfer, Pipeline Measurement, Allocation Metering, Viscous/Cryogenic Fluids, Slurries, Highly Corrosive Fluids, Products With Entrained Solids/Gas |
| Industries | Oil and Gas, Chemical, Petrochemical, Water and Wastewater, Food and Beverage, Pharmaceutical, Power, Mining |
| Display | Graphic LCD, Backlit, Rotatable, Pushbutton/Optical Keys, IR Interface |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| CM01 | VFC 100 ST STEEL SIZE 1/2"-DUAL TUBE | Request quotation |
| CM02 | VFC 100 ST STEEL SIZE 1"-DUAL TUBE | Request quotation |
| CM03 | VFC 100 ST STEEL SIZE 1-1/2"-DUAL TUBE | Request quotation |
| CM04 | VFC 100 ST STEEL SIZE 2"-DUAL TUBE | Request quotation |
| CM16 | VFC 1000 TITANIUM SIZE 3"-SGL TUBE | Request quotation |
| CM20 | VFC 1000 ST STEEL SIZE 1/8"-SGL TUBE | Request quotation |
| CM41 | VFC 200 ST STEEL SIZE 4"-DUAL TUBE | Request quotation |
| CM71 | VFC 6000 SS/HASTC SIZE 1/4"-BENT TUBE | Request quotation |
| CM72 | VFC 6000 SS/HASTC SIZE 3/8"-BENT TUBE | Request quotation |
| CM73 | VFC 6000 SS/HASTC SIZE 1/2"-BENT TUBE | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
VersaFlow-Coriolis-Converter-SS-Image · Manufacturer ownership retained; republication licence not independently confirmed
VersaFlow Coriolis Image · Manufacturer ownership retained; republication licence not independently confirmed
VersaFlow Coriolis 1000 Image · Manufacturer ownership retained; republication licence not independently confirmed
VersaFlow Coriolis Converter Image · Manufacturer ownership retained; republication licence not independently confirmed
VersaFlow Coriolis 6000 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.