VersaFlow clamp-on meters measure liquid flow using sensors mounted outside an existing pipe.
VersaFlow clamp-on meters measure liquid flow using sensors mounted outside an existing pipe. They suit installations where cutting into the line is undesirable or impractical, with configurations spanning DN15 to DN4000 and designs rated to 200°C. Honeywell identifies liquids containing limited amounts of solids or gas as the intended measurement medium.
Features & Benefits
- Pipe sizes
- DN15–DN4000
- Design temperature
- Up to 200°C
- Avoids cutting the process pipe for installation
Applications
- Liquid flow measurement with limited solids or gas
Software & Interface
- Display
- Graphic LCD, Backlit; Languages: English, French, German
I/O Capabilities
- Measurement Configurations
- Single Path/Single Pipe Or Dual Path/Dual Pipe (standard)
- Recommended Mounting
- Inlet run: ~10DN straight length; Outlet run: ~5DN straight length
Environmental Conditions
- Process Temperature Range
- -40 to 120 deg C (-40 to 284 deg F) Standard; -40 to 200 deg C (-40 to 392 deg F) XT Version (option)
Communication & Protocols
- Pipe Materials Supported
- Internal/external coatings/liners fully bonded to pipe wall; Metal, plastic, ceramic, asbestos cement
- Communication
- Control Input (Standard); Current; HART® Communication; Modbus RS485 (Option); Pulse and Status Output (Standard)
Processing & Performance Metrics
- Maximum Liner Thickness
- < 20 mm (0.79 in)
Network & Connectivity Infrastructure
- Sensor Cable Length
- 6 m (18 ft), 10 m (30 ft) Fixed; Up to 25 m (75 ft) with Extension Cable and Splitter Box
Standards & Certifications
- Protection Category
- Converter: IP66/67 (NEMA6); Flow Sensor: IP66/67 (NEMA6), IP68 (optional)
- Approvals
- Ex zone 1 (ATEX and IECEx, option); QPS (US/Canada) Class I DIV 1 (option)
Technical Specifications
- Cable Connections
- 1/2 in NPT (option); M20 x 1.5 (standard); PF 1/2 in (option)
Measurement & Sensor Related (Measurement Capabilities)
- Measured Values
- Actual Volume Flow Rate; Flow Direction; Flow Speed; Mass Flow; Quality Of Signal; Signal-To-Noise Ratio; Speed Of Sound; Totalized Volume
Mechanical & Physical Properties
- Wall Thickness
- ≤ 200 mm (7.87 in)
Electrical Specifications
- Power Supply
- 100 to 230 VAC (-15/+10%); 22 VA; 24 VAC/DC (Option); 50/60 Hz (Standard); Power Consumption: DC 12 W
Applications & Compatibility
- Applications
- Acids/Corrosives; Chemical Addition; Cooling Water; Heat/Energy Measurement; Hydrocarbons; Leak Detection; Potable/Deionized/Demin Water; Process Control; Purified Water; Sanitary Flow
- Sensor Type
- Large: DN200 to DN4000 (8 to 160 in); Medium: DN50 to DN400 (2 to 16 in); Small: DN15 to DN100 (1/2 to 4 in); X-mode: DN200 to DN1250 (8 to 50 in)
Industries / Applications & Compatibility
- Industries
- Chemicals, Petrochemical, Power Plants, Water, Oil and Gas, Semiconductor, Food and Beverage, Pharmaceuticals
Others
- Storage Temperature Range
- -50 to 70 deg C; -58 to 158 deg F
- Ambient Temperature Range
- -40 to 140 deg F; -40 to 60 deg C
| Parameter | Published value / configuration |
|---|---|
| Display | Graphic LCD, Backlit; Languages: English, French, German |
| Measurement Configurations | Single Path/Single Pipe Or Dual Path/Dual Pipe (standard) |
| Recommended Mounting | Inlet run: ~10DN straight length; Outlet run: ~5DN straight length |
| Process Temperature Range | -40 to 120 deg C (-40 to 284 deg F) Standard; -40 to 200 deg C (-40 to 392 deg F) XT Version (option) |
| Pipe Materials Supported | Internal/external coatings/liners fully bonded to pipe wall; Metal, plastic, ceramic, asbestos cement |
| Communication | Control Input (Standard); Current; HART® Communication; Modbus RS485 (Option); Pulse and Status Output (Standard) |
| Maximum Liner Thickness | < 20 mm (0.79 in) |
| Sensor Cable Length | 6 m (18 ft), 10 m (30 ft) Fixed; Up to 25 m (75 ft) with Extension Cable and Splitter Box |
| Protection Category | Converter: IP66/67 (NEMA6); Flow Sensor: IP66/67 (NEMA6), IP68 (optional) |
| Approvals | Ex zone 1 (ATEX and IECEx, option); QPS (US/Canada) Class I DIV 1 (option) |
| Cable Connections | 1/2 in NPT (option); M20 x 1.5 (standard); PF 1/2 in (option) |
| Measured Values | Actual Volume Flow Rate; Flow Direction; Flow Speed; Mass Flow; Quality Of Signal; Signal-To-Noise Ratio; Speed Of Sound; Totalized Volume |
| Wall Thickness | ≤ 200 mm (7.87 in) |
| Power Supply | 100 to 230 VAC (-15/+10%); 22 VA; 24 VAC/DC (Option); 50/60 Hz (Standard); Power Consumption: DC 12 W |
| Applications | Acids/Corrosives; Chemical Addition; Cooling Water; Heat/Energy Measurement; Hydrocarbons; Leak Detection; Potable/Deionized/Demin Water; Process Control; Purified Water; Sanitary Flow |
| Sensor Type | Large: DN200 to DN4000 (8 to 160 in); Medium: DN50 to DN400 (2 to 16 in); Small: DN15 to DN100 (1/2 to 4 in); X-mode: DN200 to DN1250 (8 to 50 in) |
| Industries | Chemicals, Petrochemical, Power Plants, Water, Oil and Gas, Semiconductor, Food and Beverage, Pharmaceuticals |
| Storage Temperature Range | -50 to 70 deg C; -58 to 158 deg F |
| Ambient Temperature Range | -40 to 140 deg F; -40 to 60 deg C |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
4 parts
| Part Number | Description | Enquiry |
|---|---|---|
| SM10 | SONIC 1000-FIXED, SIZE 1/2" - 160" | Request quotation |
| SM11 | TWS 9000 CONVERTER - BASIC I/O | Request quotation |
| SM12 | TWS 9000 CONVERTER - MODULAR I/O | Request quotation |
| SM20 | SONIC 2000-PORTABLE, SIZE 1/2" - 60" | Request quotation |