V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines.

V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines. Their sealed copper registers resist condensation and water ingress, while an inductive target supports bidirectional pulse reading. The optional InVISION module provides encoded output, enabling the selected meter to join a remote-reading system without changing its underlying displacement measurement principle.

Models: V200, V210

Features & Benefits

Maximum temperature
50 °C
Maximum pressure
16 bar
Register protection
IP68
Options
Bidirectional inductive pulse or InVISION encoded output
  • Simple addition of remote-reading modules

Applications

  • Residential water consumption measurement

Detailed capabilities

V200/V210 — purpose and arrangement

V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines. Their sealed copper registers resist condensation and water ingress, while an inductive target supports bidirectional pulse reading. The optional InVISION module provides encoded output, enabling the selected meter to join a remote-reading system without changing its underlying displacement measurement principle.

Manufacturer reference ↗

Sealed register and communication options

V200/V210 use a grooved piston and a hermetically sealed copper register to resist condensation and meet the stated IP68 protection. An inductive target accepts a tamper-resistant bidirectional pulse transmitter, or an InVISION module provides an encoded reading. The module is an option added to the volumetric platform rather than a standard radio built into every meter.

Manufacturer reference ↗

Mounting and published limits

Horizontal, vertical and inclined pipelines are allowed. The page names OIML R49, EN14154 and ISO4064 and gives fifty-degree maximum water temperature and sixteen-bar pressure. Its historic European directive reference remains a source statement rather than a substitute for the selected meter’s current approval documentation.

Manufacturer reference ↗

Specifications

Dimensions & Sizes

Sizes
15 mm, 20 mm (High Accuracy Range); DN15 to DN40 (Standard Range R160)

Operating Conditions

Maximum Water Temperature
30 deg C

Measurement

Measurement Principle
Volumetric (high accuracy at low flow)
Flow Rate
High Accuracy Range: Overload Flow (Q4) - 3.125 to 5 m³/h, Permanent Flow (Q3) - 2.5 to 4 m³/h, Transitional Flow (Q2) - 10 to 20.32 l/h, Minimum Flow (Q1) - 6.25 to 12.7 l/h; Standard Range R160: Permanent Flow (Q3) - 2.5 to 16 m³/h, Overload Flow (Q4) - 3.125 to 20 m³/h, Transitional Flow (Q2) - 25 to 160 l/h, Minimum Flow (Q1) - 15.6 to 100 l/h

Performance

Accuracy Class (AC)
Exceeds Class D equivalent (high precision)

Pressure Ratings

Working Pressure
16 bar

General Overview

Applications
Domestic/commercial water metering
Meter Types
Volumetric water meters (rotary piston principle)

Physical

Dimensions
~94 to 181 mm (depending on size) Diameter x ~111 to 166 mm Height x ~110 to 300 mm Length

Safety & Compliance

Approvals
MID 2014/32/EU, OIML R49, EN14154, ISO4064

Connection Options

Models
V200 and V210
V200/V210 — manufacturer page values
ParameterPublished value / configuration
Sizes15 mm, 20 mm (High Accuracy Range); DN15 to DN40 (Standard Range R160)
Maximum Water Temperature30 deg C
Measurement PrincipleVolumetric (high accuracy at low flow)
Flow RateHigh Accuracy Range: Overload Flow (Q4) - 3.125 to 5 m³/h, Permanent Flow (Q3) - 2.5 to 4 m³/h, Transitional Flow (Q2) - 10 to 20.32 l/h, Minimum Flow (Q1) - 6.25 to 12.7 l/h; Standard Range R160: Permanent Flow (Q3) - 2.5 to 16 m³/h, Overload Flow (Q4) - 3.125 to 20 m³/h, Transitional Flow (Q2) - 25 to 160 l/h, Minimum Flow (Q1) - 15.6 to 100 l/h
Accuracy Class (AC)Exceeds Class D equivalent (high precision)
Working Pressure16 bar
ApplicationsDomestic/commercial water metering
Meter TypesVolumetric water meters (rotary piston principle)
Dimensions~94 to 181 mm (depending on size) Diameter x ~111 to 166 mm Height x ~110 to 300 mm Length
ApprovalsMID 2014/32/EU, OIML R49, EN14154, ISO4064
ModelsV200 and V210

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
46491-09SUB-METERING KIT, 20MM V200 DCVRequest quotation
46491-22SERVICE BOX ASSY, 20MM V100 DCVRequest quotation
46491-23SERVICE BOX ASSY, 20MM V200 DCVRequest quotation
46491-26SERVICE BOX ASSY, 20MM V200 DCVRequest quotation
50200/51METER, 20MM V200 DCV, N&TRequest quotation
50200/51LOMETER,20MM V200 DCV, N&T,(LOGAN)Request quotation
50200/51QUUMETER,20MM V200 DCV,N&T,(QUU S/N)Request quotation
50200/51UMETER, 20MM V200 DCV, N&TRequest quotation
50200/51UEMETER,20MM V200 DCV,N&T,(UE S/N)Request quotation
50200/51UE/LLMETER,20MM V200 DCV,N&T,(UE S/N)Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/water/residential-metering/volumetric-meters/v200-v210

Last source check: 2026-11-02

V200/V210 product image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.