V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines.
V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines. Their sealed copper registers resist condensation and water ingress, while an inductive target supports bidirectional pulse reading. The optional InVISION module provides encoded output, enabling the selected meter to join a remote-reading system without changing its underlying displacement measurement principle.
Models: V200, V210
Features & Benefits
- Maximum temperature
- 50 °C
- Maximum pressure
- 16 bar
- Register protection
- IP68
- Options
- Bidirectional inductive pulse or InVISION encoded output
- Simple addition of remote-reading modules
Applications
- Residential water consumption measurement
Detailed capabilities
V200/V210 — purpose and arrangement
V200 and V210 measure water volumetrically in horizontal, vertical or inclined pipelines. Their sealed copper registers resist condensation and water ingress, while an inductive target supports bidirectional pulse reading. The optional InVISION module provides encoded output, enabling the selected meter to join a remote-reading system without changing its underlying displacement measurement principle.
Sealed register and communication options
V200/V210 use a grooved piston and a hermetically sealed copper register to resist condensation and meet the stated IP68 protection. An inductive target accepts a tamper-resistant bidirectional pulse transmitter, or an InVISION module provides an encoded reading. The module is an option added to the volumetric platform rather than a standard radio built into every meter.
Mounting and published limits
Horizontal, vertical and inclined pipelines are allowed. The page names OIML R49, EN14154 and ISO4064 and gives fifty-degree maximum water temperature and sixteen-bar pressure. Its historic European directive reference remains a source statement rather than a substitute for the selected meter’s current approval documentation.
Dimensions & Sizes
- Sizes
- 15 mm, 20 mm (High Accuracy Range); DN15 to DN40 (Standard Range R160)
Operating Conditions
- Maximum Water Temperature
- 30 deg C
Measurement
- Measurement Principle
- Volumetric (high accuracy at low flow)
- Flow Rate
- High Accuracy Range: Overload Flow (Q4) - 3.125 to 5 m³/h, Permanent Flow (Q3) - 2.5 to 4 m³/h, Transitional Flow (Q2) - 10 to 20.32 l/h, Minimum Flow (Q1) - 6.25 to 12.7 l/h; Standard Range R160: Permanent Flow (Q3) - 2.5 to 16 m³/h, Overload Flow (Q4) - 3.125 to 20 m³/h, Transitional Flow (Q2) - 25 to 160 l/h, Minimum Flow (Q1) - 15.6 to 100 l/h
Performance
- Accuracy Class (AC)
- Exceeds Class D equivalent (high precision)
Pressure Ratings
- Working Pressure
- 16 bar
General Overview
- Applications
- Domestic/commercial water metering
- Meter Types
- Volumetric water meters (rotary piston principle)
Physical
- Dimensions
- ~94 to 181 mm (depending on size) Diameter x ~111 to 166 mm Height x ~110 to 300 mm Length
Safety & Compliance
- Approvals
- MID 2014/32/EU, OIML R49, EN14154, ISO4064
Connection Options
- Models
- V200 and V210
| Parameter | Published value / configuration |
|---|---|
| Sizes | 15 mm, 20 mm (High Accuracy Range); DN15 to DN40 (Standard Range R160) |
| Maximum Water Temperature | 30 deg C |
| Measurement Principle | Volumetric (high accuracy at low flow) |
| Flow Rate | High Accuracy Range: Overload Flow (Q4) - 3.125 to 5 m³/h, Permanent Flow (Q3) - 2.5 to 4 m³/h, Transitional Flow (Q2) - 10 to 20.32 l/h, Minimum Flow (Q1) - 6.25 to 12.7 l/h; Standard Range R160: Permanent Flow (Q3) - 2.5 to 16 m³/h, Overload Flow (Q4) - 3.125 to 20 m³/h, Transitional Flow (Q2) - 25 to 160 l/h, Minimum Flow (Q1) - 15.6 to 100 l/h |
| Accuracy Class (AC) | Exceeds Class D equivalent (high precision) |
| Working Pressure | 16 bar |
| Applications | Domestic/commercial water metering |
| Meter Types | Volumetric water meters (rotary piston principle) |
| Dimensions | ~94 to 181 mm (depending on size) Diameter x ~111 to 166 mm Height x ~110 to 300 mm Length |
| Approvals | MID 2014/32/EU, OIML R49, EN14154, ISO4064 |
| Models | V200 and V210 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 46491-09 | SUB-METERING KIT, 20MM V200 DCV | Request quotation |
| 46491-22 | SERVICE BOX ASSY, 20MM V100 DCV | Request quotation |
| 46491-23 | SERVICE BOX ASSY, 20MM V200 DCV | Request quotation |
| 46491-26 | SERVICE BOX ASSY, 20MM V200 DCV | Request quotation |
| 50200/51 | METER, 20MM V200 DCV, N&T | Request quotation |
| 50200/51LO | METER,20MM V200 DCV, N&T,(LOGAN) | Request quotation |
| 50200/51QUU | METER,20MM V200 DCV,N&T,(QUU S/N) | Request quotation |
| 50200/51U | METER, 20MM V200 DCV, N&T | Request quotation |
| 50200/51UE | METER,20MM V200 DCV,N&T,(UE S/N) | Request quotation |
| 50200/51UE/LL | METER,20MM V200 DCV,N&T,(UE S/N) | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
V200/V210 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.