Volumetric Meters
V110 Volumetric Water Meter
V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification.
V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification. Its volumetric mechanism permits different mounting positions, with pulse output available for data collection. Pressure limits depend on size, and the manufacturer publishes a specific South African installation requirement for approved pre-plumbed boxes, which must be retained when selecting that market configuration.
Models: V110 Volumetric Water Meter
Features & Benefits
- Sizes
- 15, 20 and 25 mm
- Flow range
- 15 l/h–7 m³/h
- Maximum pressure
- 10 bar, 16 bar on 15 mm
- Resin body addresses aggressive-water conditions
Applications
- Domestic volumetric water metering
Detailed capabilities
V110 Volumetric Water Meter — purpose and arrangement
V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification. Its volumetric mechanism permits different mounting positions, with pulse output available for data collection. Pressure limits depend on size, and the manufacturer publishes a specific South African installation requirement for approved pre-plumbed boxes, which must be retained when selecting that market configuration.
Size-dependent volumetric performance
V110 permits any installation position and offers pulse output. Its grooved piston applies only to fifteen- and twenty-millimeter versions. The source lists class-C performance, sizes15/20/25mm and15l/h–7m³/h flow, with ten-bar maximum pressure except sixteen bar for the fifteen-millimeter size. Those exceptions remain explicit rather than giving all sizes the highest rating.
South African manufacturer installation condition
For South African customers, the page requires an approved pre-plumbed meter-box assembly and states that an alternative loose-plastic-meter installation voids the manufacturer warranty. It says loose meters are supplied only to replace meters in Honeywell boxes. This is retained as the manufacturer’s market-specific condition and published reference, not generalized to installations in every country.
General Overview
- Applications
- Domestic/commercial water metering, energy management systems
- Meter Types
- Volumetric (rotary piston) cold water meter
- Installation Orientation
- Horizontal, vertical, or inclined without accuracy impact
Pressure Ratings
- Working Pressure
- 10 bar (16 bar for 15 mm size)
Flow & Performance
- Turndown Ratio
- Q3/Q1 ≈ R160
Dimensions & Sizes
- Sizes
- 15 mm, 20 mm, 25 mm
Functional Features
- Register Type
- Fully sealed, vacuum‑filled register
Outputs
- Pulse Output
- 0.5 to 5 litres per pulse depending on size
Measurement
- Measurement Principle
- Rotary‑piston volumetric principle
- Flow Rate
- Minimum Flow (Q1): 15.63 to 39.38 l/h; Overload Flow (Q4): 3.125 to 7.875 m³/h; Starting Flow: ~5.7 to 13.2 l/h; Transitional Flow (Q2): 25 to 63 l/h
Measurement & Metrology
- Measurement Capability
- Accurate even at very low flow rates
Operating Conditions
- Maximum Water Temperature
- 30 deg C
Construction
- Materials
- High-quality engineered plastics and resin
Physical
- Dimensions
- 115 to 199 mm Length x ~99 to 114 mm Diameter
Safety & Compliance
- Approvals
- MID 2004/22/EC, EN 14154, OIML R49, ISO 4064, Pressure Equipment Directive 97/23/EC
| Parameter | Published value / configuration |
|---|---|
| Applications | Domestic/commercial water metering, energy management systems |
| Meter Types | Volumetric (rotary piston) cold water meter |
| Installation Orientation | Horizontal, vertical, or inclined without accuracy impact |
| Working Pressure | 10 bar (16 bar for 15 mm size) |
| Turndown Ratio | Q3/Q1 ≈ R160 |
| Sizes | 15 mm, 20 mm, 25 mm |
| Register Type | Fully sealed, vacuum‑filled register |
| Pulse Output | 0.5 to 5 litres per pulse depending on size |
| Measurement Principle | Rotary‑piston volumetric principle |
| Flow Rate | Minimum Flow (Q1): 15.63 to 39.38 l/h; Overload Flow (Q4): 3.125 to 7.875 m³/h; Starting Flow: ~5.7 to 13.2 l/h; Transitional Flow (Q2): 25 to 63 l/h |
| Measurement Capability | Accurate even at very low flow rates |
| Maximum Water Temperature | 30 deg C |
| Materials | High-quality engineered plastics and resin |
| Dimensions | 115 to 199 mm Length x ~99 to 114 mm Diameter |
| Approvals | MID 2004/22/EC, EN 14154, OIML R49, ISO 4064, Pressure Equipment Directive 97/23/EC |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 40101-00 | METER, 15MM V110 | Request quotation |
| 40102-00 | METER, 20MM V110 | Request quotation |
| 40103-00 | METER, 25MM V110 | Request quotation |
| AW810 | 1.5 V110T NRV 'C' 114 | Request quotation |
| AW811 | V110 DN15 Q3:2,5 L165 NRV | Request quotation |
| AW812 | V110 DN20 Q3:4 L165 NRV | Request quotation |
| AW813 | V110 DN25 Q3:6,3 L199 NRV | Request quotation |
| AW815 | 2,5 V110T NRV 'C' 114 | Request quotation |
| DW109 | 15 KSM-T RDP4 M/BOX | Request quotation |
| DW209 | 25 KSM LARGE METER BOX | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
V110 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.