Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Volumetric Meters

V110 Volumetric Water Meter

V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification.

V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification. Its volumetric mechanism permits different mounting positions, with pulse output available for data collection. Pressure limits depend on size, and the manufacturer publishes a specific South African installation requirement for approved pre-plumbed boxes, which must be retained when selecting that market configuration.

Models: V110 Volumetric Water Meter

Features & Benefits

Sizes
15, 20 and 25 mm
Flow range
15 l/h–7 m³/h
Maximum pressure
10 bar, 16 bar on 15 mm
  • Resin body addresses aggressive-water conditions

Applications

  • Domestic volumetric water metering

Detailed capabilities

V110 Volumetric Water Meter — purpose and arrangement

V110 uses a copolymer-resin body for water that may be aggressive or cause dezincification. Its volumetric mechanism permits different mounting positions, with pulse output available for data collection. Pressure limits depend on size, and the manufacturer publishes a specific South African installation requirement for approved pre-plumbed boxes, which must be retained when selecting that market configuration.

Manufacturer reference ↗

Size-dependent volumetric performance

V110 permits any installation position and offers pulse output. Its grooved piston applies only to fifteen- and twenty-millimeter versions. The source lists class-C performance, sizes15/20/25mm and15l/h–7m³/h flow, with ten-bar maximum pressure except sixteen bar for the fifteen-millimeter size. Those exceptions remain explicit rather than giving all sizes the highest rating.

Manufacturer reference ↗

South African manufacturer installation condition

For South African customers, the page requires an approved pre-plumbed meter-box assembly and states that an alternative loose-plastic-meter installation voids the manufacturer warranty. It says loose meters are supplied only to replace meters in Honeywell boxes. This is retained as the manufacturer’s market-specific condition and published reference, not generalized to installations in every country.

Manufacturer reference ↗

Specifications

General Overview

Applications
Domestic/commercial water metering, energy management systems
Meter Types
Volumetric (rotary piston) cold water meter
Installation Orientation
Horizontal, vertical, or inclined without accuracy impact

Pressure Ratings

Working Pressure
10 bar (16 bar for 15 mm size)

Flow & Performance

Turndown Ratio
Q3/Q1 ≈ R160

Dimensions & Sizes

Sizes
15 mm, 20 mm, 25 mm

Functional Features

Register Type
Fully sealed, vacuum‑filled register

Outputs

Pulse Output
0.5 to 5 litres per pulse depending on size

Measurement

Measurement Principle
Rotary‑piston volumetric principle
Flow Rate
Minimum Flow (Q1): 15.63 to 39.38 l/h; Overload Flow (Q4): 3.125 to 7.875 m³/h; Starting Flow: ~5.7 to 13.2 l/h; Transitional Flow (Q2): 25 to 63 l/h

Measurement & Metrology

Measurement Capability
Accurate even at very low flow rates

Operating Conditions

Maximum Water Temperature
30 deg C

Construction

Materials
High-quality engineered plastics and resin

Physical

Dimensions
115 to 199 mm Length x ~99 to 114 mm Diameter

Safety & Compliance

Approvals
MID 2004/22/EC, EN 14154, OIML R49, ISO 4064, Pressure Equipment Directive 97/23/EC
V110 Volumetric Water Meter — manufacturer page values
ParameterPublished value / configuration
ApplicationsDomestic/commercial water metering, energy management systems
Meter TypesVolumetric (rotary piston) cold water meter
Installation OrientationHorizontal, vertical, or inclined without accuracy impact
Working Pressure10 bar (16 bar for 15 mm size)
Turndown RatioQ3/Q1 ≈ R160
Sizes15 mm, 20 mm, 25 mm
Register TypeFully sealed, vacuum‑filled register
Pulse Output0.5 to 5 litres per pulse depending on size
Measurement PrincipleRotary‑piston volumetric principle
Flow RateMinimum Flow (Q1): 15.63 to 39.38 l/h; Overload Flow (Q4): 3.125 to 7.875 m³/h; Starting Flow: ~5.7 to 13.2 l/h; Transitional Flow (Q2): 25 to 63 l/h
Measurement CapabilityAccurate even at very low flow rates
Maximum Water Temperature30 deg C
MaterialsHigh-quality engineered plastics and resin
Dimensions115 to 199 mm Length x ~99 to 114 mm Diameter
ApprovalsMID 2004/22/EC, EN 14154, OIML R49, ISO 4064, Pressure Equipment Directive 97/23/EC

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

V110 Volumetric Water MeterRequest quotation ›

Published part numbers

10 parts

Part NumberDescriptionEnquiry
40101-00METER, 15MM V110Request quotation
40102-00METER, 20MM V110Request quotation
40103-00METER, 25MM V110Request quotation
AW8101.5 V110T NRV 'C' 114Request quotation
AW811V110 DN15 Q3:2,5 L165 NRVRequest quotation
AW812V110 DN20 Q3:4 L165 NRVRequest quotation
AW813V110 DN25 Q3:6,3 L199 NRVRequest quotation
AW8152,5 V110T NRV 'C' 114Request quotation
DW10915 KSM-T RDP4 M/BOXRequest quotation
DW20925 KSM LARGE METER BOXRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/water/residential-metering/volumetric-meters/v110-volumetric-water-meter

Last source check: 2026-11-02

V110 Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry