Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

MBus

Falcon Pulse/MBus

Falcon adds pulse and wired M-bus communication to selected Honeywell water meters.

Falcon adds pulse and wired M-bus communication to selected Honeywell water meters. Inductive sensing links the transmitted reading with the meter mechanism, while MBConf changes the pulse increment over M-bus. Compatibility includes named bulk, volumetric and single-jet models, so the module must be chosen against the actual meter interface rather than applied universally.

Features & Benefits

Meters
H4000, C4000, V200/V210 and S150/S220
Pulse value
1–1,000 litres, programmable
  • Flexible pulse resolution supports different data systems

Applications

  • Remote water meter reading

Specifications

General Overview

Applications
Remote reading of water meters via pulse output and M‑Bus
Product Type
Combined Pulse and M‑Bus Communication Module

Operating Conditions

Storage Temperature
-20 to 70 deg C
Protection Class
IP68
Operating Temperature Range
-15 to +65 deg C

Interfaces

Standard Pulse Setting
100 litre per pulse; 100 ms pulse length

Sensing

Sensing Technology
Inductive sensing with 3 coils, non‑reactive

Power

Power Supply Mode
By M-Bus; battery supply in pulse mode or if M-Bus fails
Battery Type
3.6 V lithium
Battery Lifetime
15 years typical (at 25 deg C ambient temperature)

Electrical

M-Bus Load
1 M‑Bus load

Physical

Colour
Grey

Cabling

Cable Type
LiYY 5 x 0.14
Falcon Pulse/MBus — manufacturer page values
ParameterPublished value / configuration
ApplicationsRemote reading of water meters via pulse output and M‑Bus
Product TypeCombined Pulse and M‑Bus Communication Module
Storage Temperature-20 to 70 deg C
Protection ClassIP68
Operating Temperature Range-15 to +65 deg C
Standard Pulse Setting100 litre per pulse; 100 ms pulse length
Sensing TechnologyInductive sensing with 3 coils, non‑reactive
Power Supply ModeBy M-Bus; battery supply in pulse mode or if M-Bus fails
Battery Type3.6 V lithium
Battery Lifetime15 years typical (at 25 deg C ambient temperature)
M-Bus Load1 M‑Bus load
ColourGrey
Cable TypeLiYY 5 x 0.14

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/water/digital-metering/mbus/falcon-pulse-mbus

Last source check: 2026-11-02

Falcon Pulse/MBus product image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.