MBus
Falcon Pulse/MBus
Falcon adds pulse and wired M-bus communication to selected Honeywell water meters.
Falcon adds pulse and wired M-bus communication to selected Honeywell water meters. Inductive sensing links the transmitted reading with the meter mechanism, while MBConf changes the pulse increment over M-bus. Compatibility includes named bulk, volumetric and single-jet models, so the module must be chosen against the actual meter interface rather than applied universally.
Features & Benefits
- Meters
- H4000, C4000, V200/V210 and S150/S220
- Pulse value
- 1–1,000 litres, programmable
- Flexible pulse resolution supports different data systems
Applications
- Remote water meter reading
General Overview
- Applications
- Remote reading of water meters via pulse output and M‑Bus
- Product Type
- Combined Pulse and M‑Bus Communication Module
Operating Conditions
- Storage Temperature
- -20 to 70 deg C
- Protection Class
- IP68
- Operating Temperature Range
- -15 to +65 deg C
Interfaces
- Standard Pulse Setting
- 100 litre per pulse; 100 ms pulse length
Sensing
- Sensing Technology
- Inductive sensing with 3 coils, non‑reactive
Power
- Power Supply Mode
- By M-Bus; battery supply in pulse mode or if M-Bus fails
- Battery Type
- 3.6 V lithium
- Battery Lifetime
- 15 years typical (at 25 deg C ambient temperature)
Electrical
- M-Bus Load
- 1 M‑Bus load
Physical
- Colour
- Grey
Cabling
- Cable Type
- LiYY 5 x 0.14
| Parameter | Published value / configuration |
|---|---|
| Applications | Remote reading of water meters via pulse output and M‑Bus |
| Product Type | Combined Pulse and M‑Bus Communication Module |
| Storage Temperature | -20 to 70 deg C |
| Protection Class | IP68 |
| Operating Temperature Range | -15 to +65 deg C |
| Standard Pulse Setting | 100 litre per pulse; 100 ms pulse length |
| Sensing Technology | Inductive sensing with 3 coils, non‑reactive |
| Power Supply Mode | By M-Bus; battery supply in pulse mode or if M-Bus fails |
| Battery Type | 3.6 V lithium |
| Battery Lifetime | 15 years typical (at 25 deg C ambient temperature) |
| M-Bus Load | 1 M‑Bus load |
| Colour | Grey |
| Cable Type | LiYY 5 x 0.14 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
https://process.honeywell.com/us/en/products/utilities/water/digital-metering/mbus/falcon-pulse-mbus